| 1 |
<pre>Network Working Group D. Rand |
| 2 |
Request for Comments: 1663 Novell |
| 3 |
Category: Standards Track July 1994 |
| 4 |
|
| 5 |
|
| 6 |
<span class="h1">PPP Reliable Transmission</span> |
| 7 |
|
| 8 |
Status of this Memo |
| 9 |
|
| 10 |
This document specifies an Internet standards track protocol for the |
| 11 |
Internet community, and requests discussion and suggestions for |
| 12 |
improvements. Please refer to the current edition of the "Internet |
| 13 |
Official Protocol Standards" (STD 1) for the standardization state |
| 14 |
and status of this protocol. Distribution of this memo is unlimited. |
| 15 |
|
| 16 |
Abstract |
| 17 |
|
| 18 |
The Point-to-Point Protocol (PPP) [<a href="#ref-1" title=""The Point-to-Point Protocol (PPP)"">1</a>] provides a standard method for |
| 19 |
transporting multi-protocol datagrams over point-to-point links. |
| 20 |
|
| 21 |
This document defines a method for negotiating and using Numbered- |
| 22 |
Mode, as defined by ISO 7776 [<a href="#ref-2">2</a>], to provide a reliable serial link. |
| 23 |
|
| 24 |
This document is the product of the Point-to-Point Protocol Working |
| 25 |
Group of the Internet Engineering Task Force (IETF). Comments should |
| 26 |
be submitted to the [email protected] mailing list. |
| 27 |
|
| 28 |
Table of Contents |
| 29 |
|
| 30 |
<a href="#section-1">1</a>. Introduction .......................................... <a href="#page-1">1</a> |
| 31 |
<a href="#section-2">2</a>. Physical Layer Requirements ........................... <a href="#page-2">2</a> |
| 32 |
<a href="#section-3">3</a>. The Data Link Layer ................................... <a href="#page-2">2</a> |
| 33 |
<a href="#section-3.1">3.1</a> Frame Format ....................................... <a href="#page-2">2</a> |
| 34 |
<a href="#section-4">4</a>. Configuration Option Format ........................... <a href="#page-4">4</a> |
| 35 |
<a href="#section-5">5</a>. Numbered-Mode Operation ............................... <a href="#page-5">5</a> |
| 36 |
<a href="#section-5.1">5.1</a> Single Link ........................................ <a href="#page-6">6</a> |
| 37 |
<a href="#section-5.2">5.2</a> Inverse Multiplexing ............................... <a href="#page-6">6</a> |
| 38 |
<a href="#section-5.3">5.3</a> Using Multi-Link Procedure... ...................... <a href="#page-7">7</a> |
| 39 |
<a href="#section-5.4">5.4</a> LAPB Parameter defaults ............................ <a href="#page-8">8</a> |
| 40 |
SECURITY CONSIDERATIONS ...................................... <a href="#page-9">9</a> |
| 41 |
REFERENCES ................................................... <a href="#page-9">9</a> |
| 42 |
ACKNOWLEDGEMENTS ............................................. <a href="#page-9">9</a> |
| 43 |
CHAIR'S ADDRESS .............................................. <a href="#page-10">10</a> |
| 44 |
AUTHOR'S ADDRESS ............................................. <a href="#page-10">10</a> |
| 45 |
|
| 46 |
|
| 47 |
|
| 48 |
|
| 49 |
|
| 50 |
|
| 51 |
|
| 52 |
<span class="grey">Rand [Page 1]</span></pre> |
| 53 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span> |
| 54 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 55 |
|
| 56 |
|
| 57 |
<span class="h2"><a class="selflink" id="section-1" href="#section-1">1</a>. Introduction</span> |
| 58 |
|
| 59 |
By default, PPP packets over HDLC framed links consist of |
| 60 |
"connectionless" datagrams. If reliable transmission over the HDLC |
| 61 |
link is desired, the implementation MUST specify the Numbered-Mode |
| 62 |
Configuration Option during Link Establishment phase. |
| 63 |
|
| 64 |
Generally, serial link reliability is not a major issue. The |
| 65 |
architecture of protocols used in datagram networking presume |
| 66 |
best-effort non-sequential delivery. When errors are detected, |
| 67 |
datagrams |
| 68 |
are discarded. |
| 69 |
|
| 70 |
However, in certain circumstances, it is advisable to provide a |
| 71 |
reliable link, at least for a subset of the messages. The most |
| 72 |
obvious case is when the link is compressed. Since the dictionary is |
| 73 |
recovered from the compressed data stream, and a lost datagram |
| 74 |
corrupts the dictionary, datagrams must not be lost. Not all |
| 75 |
compression types will require a reliable data stream, since the cost |
| 76 |
to detect and reset a corrupt dictionary is small. |
| 77 |
|
| 78 |
The ISO 7776 LAPB can be used guarantee delivery. This is referred |
| 79 |
to in this document as "Numbered Mode" to distinguish it from the use |
| 80 |
of "Unnumbered Information", which is standard PPP framing practice. |
| 81 |
|
| 82 |
Where multiple parallel links are used to emulate a single link of |
| 83 |
higher speed, Bridged traffic, Source Routed traffic, and traffic |
| 84 |
subjected to Van Jacobsen TCP/IP header compression must be delivered |
| 85 |
to the higher layer in a certain sequence. However, the fact of the |
| 86 |
links being relatively asynchronous makes traffic ordering uncertain. |
| 87 |
|
| 88 |
The ISO 7776 Multi-Link Procedure MAY be used to restore order. |
| 89 |
Implementation of the ISO Multi-Link Procedure is deprecated. It is |
| 90 |
recommended that the PPP multilink procedure [<a href="#ref-4" title=""PPP MultiLink Procedure"">4</a>] be used instead. |
| 91 |
|
| 92 |
<span class="h2"><a class="selflink" id="section-2" href="#section-2">2</a>. Physical Layer Requirements</span> |
| 93 |
|
| 94 |
PPP Reliable Transmission imposes the same requirements that are |
| 95 |
described in "PPP in HDLC Framing" [<a href="#ref-3" title=""PPP in HDLC Framing"">3</a>], with the following |
| 96 |
exceptions. |
| 97 |
|
| 98 |
Control Signals |
| 99 |
|
| 100 |
While PPP does not normally require the use of control signals, |
| 101 |
implementation of Numbered-Mode LAPB or LAPD requires the |
| 102 |
provision of control signals, which indicate when the link has |
| 103 |
become connected or disconnected. These in turn provide the Up |
| 104 |
and Down events to the LCP state machine. |
| 105 |
|
| 106 |
|
| 107 |
|
| 108 |
<span class="grey">Rand [Page 2]</span></pre> |
| 109 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span> |
| 110 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 111 |
|
| 112 |
|
| 113 |
<span class="h2"><a class="selflink" id="section-3" href="#section-3">3</a>. The Data Link Layer</span> |
| 114 |
|
| 115 |
Numbered-Mode affects only the Address and Control fields. The |
| 116 |
remainder of the frame conforms to the framing in use for PPP. |
| 117 |
|
| 118 |
The Address Field of the frame MUST take the value announced in the |
| 119 |
Numbered-Mode Configuration Option, and the Control Field MAY take |
| 120 |
any value valid in ISO 7776. |
| 121 |
|
| 122 |
Once the link enters Numbered-Mode, Numbered-Mode MUST be used on all |
| 123 |
frames, as some implementations do not support the use of the |
| 124 |
Unnumbered-Information control field or the use of the All-Stations |
| 125 |
address intermixed with Numbered-Mode frames. |
| 126 |
|
| 127 |
<span class="h3"><a class="selflink" id="section-3.1" href="#section-3.1">3.1</a>. Frame Format</span> |
| 128 |
|
| 129 |
The following frame format is valid under Numbered-Mode. The fields |
| 130 |
are transmitted from left to right. |
| 131 |
|
| 132 |
Numbered Mode |
| 133 |
+----------+----------+----------+ |
| 134 |
| Flag | Address | Control | |
| 135 |
| 01111110 |1-2 octets|1-2 octets| |
| 136 |
+----------+----------+----------+ |
| 137 |
+----------+-------------+---------+ |
| 138 |
| Protocol | Information | Padding | |
| 139 |
|1-2 octets| * | * | |
| 140 |
+----------+-------------+---------+ |
| 141 |
+----------+----------+----------------- |
| 142 |
| FCS | Flag | Inter-frame Fill |
| 143 |
| 16 bits | 01111110 | or next Address |
| 144 |
+----------+----------+----------------- |
| 145 |
|
| 146 |
The Protocol, Information and Padding fields are described in the |
| 147 |
Point-to-Point Protocol Encapsulation [<a href="#ref-1" title=""The Point-to-Point Protocol (PPP)"">1</a>]. The FCS and Flag Sequence |
| 148 |
fields are described in "PPP in HDLC Framing" [<a href="#ref-3" title=""PPP in HDLC Framing"">3</a>]. |
| 149 |
|
| 150 |
<span class="h2"><a class="selflink" id="section-4" href="#section-4">4</a>. Configuration Option Format</span> |
| 151 |
|
| 152 |
Description |
| 153 |
|
| 154 |
The LCP Numbered-Mode Configuration Option negotiates the use of |
| 155 |
Numbered-Mode on the link. By default or ultimate disagreement, |
| 156 |
Unnumbered-Mode is used. |
| 157 |
|
| 158 |
A summary of the Numbered-Mode Configuration Option format is shown |
| 159 |
below. The fields are transmitted from left to right. |
| 160 |
|
| 161 |
|
| 162 |
|
| 163 |
|
| 164 |
<span class="grey">Rand [Page 3]</span></pre> |
| 165 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span> |
| 166 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 167 |
|
| 168 |
|
| 169 |
0 1 2 3 |
| 170 |
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 |
| 171 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |
| 172 |
| Type | Length | Window | Address... |
| 173 |
+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ |
| 174 |
|
| 175 |
Type |
| 176 |
|
| 177 |
11 |
| 178 |
|
| 179 |
Length |
| 180 |
|
| 181 |
>= 4 |
| 182 |
|
| 183 |
Window |
| 184 |
|
| 185 |
A value between 1 and 127. This indicates the number of frames |
| 186 |
the receiver will buffer, which is the maximum number that the |
| 187 |
sender should send without receiving an acknowledgement. If |
| 188 |
window < 8, then modulo 8 sequencing is used on the link. |
| 189 |
Otherwise, modulo 128 sequencing is used. |
| 190 |
|
| 191 |
It is conceivable and legal that differing window values might be |
| 192 |
announced. However, it is not permitted for one system to use |
| 193 |
modulo 8 sequencing and the other to use modulo 128. Therefore, |
| 194 |
the rule is: a Configure-Nak may reduce the window but may not |
| 195 |
increase it. |
| 196 |
|
| 197 |
Address |
| 198 |
|
| 199 |
An HDLC Address as specified in ISO 3309. ISO 7776 specifies four |
| 200 |
of the possible values: 1 and 3 for single link operation, 7 and |
| 201 |
15 for the Multi-Link Procedure. Other values consistent with ISO |
| 202 |
3309 are considered legal. |
| 203 |
|
| 204 |
Implementation of the Multi-Link Procedure is optional; A |
| 205 |
|
| 206 |
Configure-Nak may therefore force a change from MLP to single link |
| 207 |
mode, but not the reverse. |
| 208 |
|
| 209 |
Should the address be zero upon receipt, the receiver MUST |
| 210 |
Configure-Nak with an appropriate address. If both peers send |
| 211 |
address zero, the system advertising the numerically smaller |
| 212 |
window will select the smaller address. If both windows are the |
| 213 |
same size, a random choice MUST be made; when good sources of |
| 214 |
randomness are used, the link will converge in a reasonable time. |
| 215 |
|
| 216 |
|
| 217 |
|
| 218 |
|
| 219 |
|
| 220 |
<span class="grey">Rand [Page 4]</span></pre> |
| 221 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span> |
| 222 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 223 |
|
| 224 |
|
| 225 |
If magic numbers have been negotiated on the link, the system with |
| 226 |
the numerically smaller magic number SHOULD specify the smaller |
| 227 |
address. |
| 228 |
|
| 229 |
<span class="h2"><a class="selflink" id="section-5" href="#section-5">5</a>. Numbered-Mode Operation</span> |
| 230 |
|
| 231 |
When using the Numbered-Mode, each link is established in the usual |
| 232 |
manner for the type of link. The Numbered-Mode Configuration Option |
| 233 |
is negotiated, the Magic-Number Configuration Option MUST also be |
| 234 |
negotiated, and the Address-and-Control-Field-Compression |
| 235 |
Configuration Option MUST NOT be negotiated. |
| 236 |
|
| 237 |
Following the successful negotiation of the Numbered-Mode |
| 238 |
Configuration Option during LCP Link Establishment phase, the system |
| 239 |
with the numerically smaller Magic-Number will send a SABM or |
| 240 |
SABM(E), and the other will respond with a UA. In the event that |
| 241 |
either the SABM or UA is lost, this exchange may be repeated |
| 242 |
according to the same parameters as the configuration exchange |
| 243 |
itself, using the Restart Timer and counter values. Authentication, |
| 244 |
Link Quality Determination, and NCP Configuration follow this step. |
| 245 |
|
| 246 |
Once the link has been established with Numbered-Mode, when re- |
| 247 |
negotiation of link configuration occurs, the entire re-negotiation |
| 248 |
MUST be conducted in Numbered-Mode. If the Numbered-Mode |
| 249 |
Configuration Option is not successfully re-negotiated, the link |
| 250 |
reverts to Unnumbered-Information operation prior to Authentication, |
| 251 |
Link Quality Determination, and NCP Configuration. |
| 252 |
|
| 253 |
When an implementation which is capable of Numbered-Mode, and is not |
| 254 |
currently configured for Numbered-Mode operation, detects a frame |
| 255 |
which has a correct FCS but does not have a UI Control octet, the |
| 256 |
implementation MUST send a DM message, immediately followed by a LCP |
| 257 |
Configure-Request. |
| 258 |
|
| 259 |
When an implementation which is currently configured for Numbered- |
| 260 |
Mode operation receives a DM message, it MUST revert to Unnumbered- |
| 261 |
Information operation, and immediately send a LCP Configure-Request. |
| 262 |
|
| 263 |
<span class="h3"><a class="selflink" id="section-5.1" href="#section-5.1">5.1</a>. Single Link</span> |
| 264 |
|
| 265 |
When Network-Layer packets are sent over a single link, the packets |
| 266 |
are encapsulated in the following order: |
| 267 |
|
| 268 |
+----------+ +----------+ +----------+ |
| 269 |
| | | | | Numbered | |
| 270 |
| Header |-->| Data |-->| Mode |--> link |
| 271 |
| Compress | | Compress | | Header | |
| 272 |
+----------+ +----------+ +----------+ |
| 273 |
|
| 274 |
|
| 275 |
|
| 276 |
<span class="grey">Rand [Page 5]</span></pre> |
| 277 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span> |
| 278 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 279 |
|
| 280 |
|
| 281 |
<span class="h3"><a class="selflink" id="section-5.2" href="#section-5.2">5.2</a>. Inverse Multiplexing</span> |
| 282 |
|
| 283 |
Since sending several connections over a single link is often called |
| 284 |
"multiplexing", sending packets from a single connection over |
| 285 |
multiple parallel links is sometimes called "inverse-multiplexing". |
| 286 |
By default, PPP performs no special processing for such links. Each |
| 287 |
link is established and terminated independently, negotiates its own |
| 288 |
configuration options, and may have different combinations of such |
| 289 |
options as ACCM, Protocol Field Compression and IP-Address. This |
| 290 |
facilitates using the links simultaneously over dissimilar media, |
| 291 |
such as 56K sync with async backup. |
| 292 |
|
| 293 |
Every link in a single machine MUST have different Magic Numbers, and |
| 294 |
each end of every link between two peers SHOULD have Magic Numbers |
| 295 |
which are unique to those peers. This protects against patch-panel |
| 296 |
errors in addition to looped-back links. |
| 297 |
|
| 298 |
The distribution to each link is controlled by higher level routing |
| 299 |
mechanisms. When Network-Layer specific compression techniques (such |
| 300 |
as Van Jacobsen Compression) rely on sequential delivery, without |
| 301 |
Multi-Link Procedure support such compression MUST be applied on a |
| 302 |
link by link basis. |
| 303 |
|
| 304 |
+----------+ +----------+ +----------+ |
| 305 |
| | | | | Numbered | |
| 306 |
+--->| Header |-->| Data |-->| Mode |--> link 1 |
| 307 |
| | Compress | | Compress | | Header | |
| 308 |
+--------------+ +----------+ +----------+ +----------+ |
| 309 |
| Distribution | |
| 310 |
+--------------+ +----------+ +----------+ +----------+ |
| 311 |
| | | | | | Numbered | |
| 312 |
+--->| Header |-->| Data |-->| Mode |--> link 2 |
| 313 |
| Compress | | Compress | | Header | |
| 314 |
+----------+ +----------+ +----------+ |
| 315 |
|
| 316 |
<span class="h3"><a class="selflink" id="section-5.3" href="#section-5.3">5.3</a>. Using Multi-Link Procedure</span> |
| 317 |
|
| 318 |
This document does not offer a standard for ISO Multi-Link, but does |
| 319 |
offer a method for agreeing on the addressing scheme usable with |
| 320 |
Multi-Link. A sample implementation is shown below. Implementation |
| 321 |
of Multi-Link is not required. |
| 322 |
|
| 323 |
When using the ISO 7776 Multi-Link Procedure, each link is |
| 324 |
established as described above. In addition, the Numbered-Mode |
| 325 |
Configuration Option is negotiated with appropriate addresses for the |
| 326 |
Multi-Link Procedure. The distribution to each link is controlled by |
| 327 |
the Multi-Link Procedure, as is the recovery of sequence in the |
| 328 |
receiving system. |
| 329 |
|
| 330 |
|
| 331 |
|
| 332 |
<span class="grey">Rand [Page 6]</span></pre> |
| 333 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span> |
| 334 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 335 |
|
| 336 |
|
| 337 |
+---> link 1 |
| 338 |
+----------+ +----------+ +----------+ | |
| 339 |
| | | | | Multi | +--------------+ |
| 340 |
| Header |-->| Data |-->| Link |-->| Distribution | |
| 341 |
| Compress | | Compress | | Procedure| +--------------+ |
| 342 |
+----------+ +----------+ +----------+ | |
| 343 |
+---> link 2 |
| 344 |
|
| 345 |
<span class="h3"><a class="selflink" id="section-5.4" href="#section-5.4">5.4</a>. LAPB Parameter defaults</span> |
| 346 |
|
| 347 |
The following guidelines specify the default values of LAPB |
| 348 |
configurable parameters. |
| 349 |
|
| 350 |
Timer T1 |
| 351 |
|
| 352 |
Timer T1 is the maximum time permitted before a retransmission |
| 353 |
is started, as a result of no response to a transmitted I |
| 354 |
frame. This value must be greater than the time required for a |
| 355 |
maximum sized frame to be received by the other side of the |
| 356 |
link, and for a response to be generated for the frame. This |
| 357 |
SHOULD be determined dynamically, based on the measured round |
| 358 |
trip time delay of the link at the LAPB level. In the event |
| 359 |
that the system cannot determine the round trip time of the |
| 360 |
link, this value SHOULD be set to twice the bit rate of the |
| 361 |
link, divided by the maximum number of bits per frame, plus 100 |
| 362 |
milliseconds processing time. For example, on a 14,400 bps |
| 363 |
link, with a maximum frame size of 8000 bits (1000 octects), |
| 364 |
the T1 value would be set to 3.7 seconds. |
| 365 |
|
| 366 |
Timer T3 |
| 367 |
|
| 368 |
Timer T3 gives an indication of the idle state of the link. |
| 369 |
Its value must be greater than the T1 value. |
| 370 |
|
| 371 |
Maximum number of attempts to complete a transmission, N2 |
| 372 |
|
| 373 |
Parameter N2 gives the maximum number of retransmission |
| 374 |
attempts for a given frame. If this value is exceeded, the |
| 375 |
link SHOULD be terminated. The default value for parameter N2 |
| 376 |
SHOULD be 3. |
| 377 |
|
| 378 |
Security Considerations |
| 379 |
|
| 380 |
Security issues are not discussed in this memo. |
| 381 |
|
| 382 |
|
| 383 |
|
| 384 |
|
| 385 |
|
| 386 |
|
| 387 |
|
| 388 |
<span class="grey">Rand [Page 7]</span></pre> |
| 389 |
<hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span> |
| 390 |
<span class="grey"><a href="./rfc1663">RFC 1663</a> PPP Reliable Transmission July 1994</span> |
| 391 |
|
| 392 |
|
| 393 |
References |
| 394 |
|
| 395 |
[<a id="ref-1">1</a>] Simpson, W., Editor, "The Point-to-Point Protocol (PPP)", STD 51, |
| 396 |
<a href="./rfc1661">RFC 1661</a>, Daydreamer, July 1994. |
| 397 |
|
| 398 |
[<a id="ref-2">2</a>] ISO 7776, Information Processing Systems - Data Communication - |
| 399 |
High Level Data Link Control Procedures - Description of the X.25 |
| 400 |
LAPB-Compatible DTE Data Link Procedures |
| 401 |
|
| 402 |
[<a id="ref-3">3</a>] Simpson, W., Editor, "PPP in HDLC Framing", STD 51, <a href="./rfc1662">RFC 1662</a>, |
| 403 |
Daydreamer, July 1994. |
| 404 |
|
| 405 |
[<a id="ref-4">4</a>] Sklower, K., <a style="text-decoration: none" href='https://www.google.com/search?sitesearch=datatracker.ietf.org%2Fdoc%2Fhtml%2F&q=inurl:draft-+%22PPP+MultiLink+Procedure%22'>"PPP MultiLink Procedure"</a>, Work in Progress. |
| 406 |
|
| 407 |
Acknowledgments |
| 408 |
|
| 409 |
Fred Baker was the original author of this document. |
| 410 |
|
| 411 |
Bill Simpson contributed materially to the document. |
| 412 |
|
| 413 |
Chair's Address |
| 414 |
|
| 415 |
The working group can be contacted via the current chair: |
| 416 |
|
| 417 |
Fred Baker |
| 418 |
Advanced Computer Communications |
| 419 |
315 Bollay Drive |
| 420 |
Santa Barbara, California 93117 |
| 421 |
|
| 422 |
EMail: [email protected] |
| 423 |
|
| 424 |
Author's Address |
| 425 |
|
| 426 |
Questions about this memo can also be directed to: |
| 427 |
|
| 428 |
Dave Rand |
| 429 |
2180 Fortune Drive |
| 430 |
San Jose, CA 95131 |
| 431 |
|
| 432 |
Phone: +1 408 321-1259 |
| 433 |
EMail: [email protected] |
| 434 |
|
| 435 |
|
| 436 |
|
| 437 |
|
| 438 |
|
| 439 |
|
| 440 |
|
| 441 |
|
| 442 |
|
| 443 |
|
| 444 |
Rand [Page 8] |
| 445 |
</pre> |