1 <pre>Network Working Group Bob Anderson
2 Request for Comments: 138 Rand
3 NIC 6715 Vint Cerf
4 UCLA
5 Eric Harslem
6 John Heafner
7 Rand
8 Jim Madden
9 U. of Illinois
10 Bob Metcalfe
11 MIT
12 Arie Shoshani
13 SDC
14 Jim White
15 UCSB
16 David Wood
17 Mitre
18 28 April 1971
19
20 <span class="h1">STATUS REPORT ON PROPOSED DATA RECONFIGURATION SERVICE</span>
21
22 CONTENTS
23 <a href="#appendix-I">I</a>. INTRODUCTION ................................. <a href="#page-2">2</a>
24
25 Purpose of this RFC .......................... <a href="#page-2">2</a>
26 Motivation ................................... <a href="#page-2">2</a>
27
28 II. OVERVIEW OF DATA RECONFIGURATION SERVICE ..... <a href="#page-3">3</a>
29
30 Elements of Data Reconfiguration Service ..... <a href="#page-3">3</a>
31 Conceptual Network Connections ............... <a href="#page-3">3</a>
32 Connection Protocols and Message Formats ..... <a href="#page-4">4</a>
33 Example Connection Configurations ............ <a href="#page-6">6</a>
34
35 III. THE FORM MACHINE ............................. <a href="#page-7">7</a>
36
37 Input/Output Stream and Forms ................ <a href="#page-7">7</a>
38 Form Machine BNF Syntax ...................... <a href="#page-7">7</a>
39 Alternate Specification of Form Machine Syntax 8
40 Forms ........................................ <a href="#page-9">9</a>
41 Rules ........................................ <a href="#page-10">10</a>
42 Terms ........................................ <a href="#page-10">10</a>
43
44 Term Format 1 .............................. <a href="#page-11">11</a>
45 Term Format 2 .............................. <a href="#page-11">11</a>
46 Term Format 3 .............................. <a href="#page-13">13</a>
47 Term Format 4 .............................. <a href="#page-13">13</a>
48 Application of a Term ...................... <a href="#page-14">14</a>
49
50
51
52 <span class="grey">Anderson, et al. [Page 1]</span></pre>
53 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-2" ></span>
54 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
55
56
57 Restrictions and Interpretations of
58 Term Functions ........................... <a href="#page-14">14</a>
59 Term and Rule Sequencing ..................... <a href="#page-16">16</a>
60
61 IV. EXAMPLES ..................................... <a href="#page-16">16</a>
62
63 Remarks ...................................... <a href="#page-16">16</a>
64 Field Insertion .............................. <a href="#page-17">17</a>
65 Deletion ..................................... <a href="#page-17">17</a>
66 Variable Length Records ...................... <a href="#page-17">17</a>
67 String Length Computation .................... <a href="#page-18">18</a>
68 Transposition ................................ <a href="#page-18">18</a>
69 Character Packing and Unpacking .............. <a href="#page-18">18</a>
70
71 V. PROPOSED USES OF DATA RECONFIGURATION SERVICE 19
72
73 VI. IMPLEMENTATION PLANS ......................... <a href="#page-20">20</a>
74
75 <a href="#appendix-A">Appendix A</a> ......................................... <a href="#page-21">21</a>
76
77 Note 1 to the DRS Working Group .............. <a href="#page-21">21</a>
78 Note 2 to the DRS Working Group .............. <a href="#page-22">22</a>
79
80 <span class="h2"><a class="selflink" id="appendix-I" href="#appendix-I">I</a>. INTRODUCTION</span>
81
82 PURPOSE OF THIS RFC
83
84 The purpose of this RFC is to describe, in part, a proposed Network
85 experiment and to solicit comments on any aspect of the experiment.
86 The experiment involves a software mechanism to reformat Network data
87 streams. The mechanism can be adapted to numerous Network
88 application programs. We hope that the results of the experiment
89 will lead to a further standard service that embodies the principles
90 described in this RFC. We would like comments on the
91 appropriateness of this work as a Network experiment and also
92 comments on particular Network data reformatting needs that could not
93 easily be accomplished using these techniques.
94
95 MOTIVATION
96
97 Application programs require specific data I/O formats yet the
98 formats are different from program to program. We take the position
99 that the Network should adapt to the individual program requirements
100 rather than changing each program to comply with a standard. This
101 position doesn't preclude the use of standards that describe the
102 formats of regular message contents; it is merely an interpretation
103 of a standard as being a desirable mode of operation but not a
104 necessary one.
105
106
107
108 <span class="grey">Anderson, et al. [Page 2]</span></pre>
109 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-3" ></span>
110 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
111
112
113 In addition to differing program requirements, a format mismatch
114 problem occurs where users wish to employ many different kinds of
115 consoles to attach to a single service program. It is desirable to
116 have the Network adapt to individual console configurations rather
117 than requiring unique software packages for each console
118 transformation.
119
120 One approach to providing adaptation is for those sites with
121 substantial computing power to offer a data reconfiguration service;
122 a proposed example of such a service is described here.
123
124 The envisioned modus operandi of the service is that an applications
125 programmer defines _forms_ that describe data reconfigurations. The
126 service stores the forms by name. At a later time, a user (perhaps a
127 non-programmer) employs the service to accomplish a particular
128 transformation of a Network data stream, simply by calling the form
129 by name.
130
131 We have attempted to provide a notation tailored to some specifically
132 needed instances of data reformatting while keeping the notation and
133 its underlying implementation within some utility range that is
134 bounded on the lower end by a notation expressive enough to make the
135 experimental service useful, and that is bounded on the upper end by
136 a notation short of a general purpose programming language.
137
138
139 II. OVERVIEW OF THE DATA RECONFIGURATION SERVICE
140
141 ELEMENTS OF THE DATA RECONFIGURATION SERVICE
142
143 An implementation of the Data Reconfiguration Service (DRS) includes
144 modules for connection protocols, a handler of some requests that can
145 be made of the service, a compiler and/or interpreter (called the
146 Form Machine) to act on those requests, and a file storage module for
147 saving and retrieving definitions of data reconfigurations (forms).
148 This section highlights connection protocols and requests. The next
149 section covers the Form Machine language in some detail. File
150 storage is not described in this document because it is transparent
151 to the use of the service and its implementation is different at each
152 DRS host.
153
154 CONCEPTUAL NETWORK CONNECTIONS
155
156 There are three conceptual Network connections to the DRS, see Fig.
157 1.
158
159 1) The control connection (CC) is between an originating user
160 and the DRS. A form specifying data reconfiguration is
161
162
163
164 <span class="grey">Anderson, et al. [Page 3]</span></pre>
165 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-4" ></span>
166 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
167
168
169 defined over this connection and is applied to data passing
170 over the two connections described below.
171 2) The user connection (UC) is between a user process and the
172 DRS.
173 3) The server connection (SC) is between the DRS and the
174 serving process.
175
176 Since the goal is to adapt the Network to user and server processes,
177 a minimum of requirements are imposed on the UC and SC.
178
179
180 +-------------+ CC +-----------+ SC +-----------+
181 | ORIGINATING +--------+ DRS +--------+ SERVER |
182 | USER | ^ | | ^ | PROCESS |
183 +-------------+ | +------+----+ | +-----------+
184 | / |
185 Telnet / &lt;------ Simplex or Duplex
186 Protocol UC/ Connections
187 Connection /
188 /
189 +-----+-----+
190 | USER |
191 | PROCESS |
192 +-----------+
193
194 Figure 1. DRS Network Connections
195
196
197 CONNECTION PROTOCOLS AND MESSAGE FORMATS
198
199 Over a control connection the dialog is directly between an
200 originating user and the DRS. Here the user is defining forms or
201 assigning forms to connections for reformatting.
202
203 The user connects to the DRS via the initial connection protocol
204 (ICP) specified in NWG/RFC #80, version 1. Rather than going through
205 a logger, the user calls on a particular socket on which the DRS
206 always listens. DRS switches the user to another socket pair.
207
208 Messages sent over a control connection are of the types and formats
209 to be specified for TELNET. Thus, a user at a terminal should be
210 able to connect to a DRS via his local TELNET, for example, as shown
211 in Fig. 2.
212
213
214
215
216
217
218
219
220 <span class="grey">Anderson, et al. [Page 4]</span></pre>
221 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-5" ></span>
222 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
223
224
225 +--------------+
226 +--------+ CC | |
227 +-------+ TELNET +-------+ DRS |
228 | +--------+ | |
229 | +--------------+
230 +----------+---------+
231 | USER |
232 |(TERMINAL OR PROGRAM|
233 +--------------------+
234
235 Figure 2. A TELNET Connection to DRS
236
237 When a user connects to DRS he supplies a six-character user ID (UID)
238 as a qualifier to guarantee the uniqueness of his form names. He
239 will have (at least) the following commands:
240
241 1. DEFFORM (name)
242 2. ENDFORM (name)
243
244 These two commands define a form, the text of which is
245 chronologically entered between them. The (name) is six
246 characters. The form is stored in the DRS local file
247 system.
248
249 3. PURGE (name)
250
251 The named form, as qualified by the current UID, is purged
252 from the DRS file system.
253
254 4. LISTNAMES (UID)
255
256 The unqualified names of all forms assigned to UID are
257 returned.
258
259 5. LISTFORM (name)
260
261 The source text of a named form is returned.
262
263 6. DUPLEXCONNECT (user site, user send, user receive,
264 user method, server site, server
265 send, server receive, server method,
266 user-to-server form, server-to-user form)
267
268 7. SIMPLEXCONNECT (send site, send socket, send
269 method, receive site, receive
270 socket, receive method, form)
271
272
273
274
275
276 <span class="grey">Anderson, et al. [Page 5]</span></pre>
277 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-6" ></span>
278 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
279
280
281 Either one, both, or neither of the two parties specified in 6 or 7
282 may be at the same host as the party issuing the request. Sites and
283 sockets specify user and server for the connection. Method indicates
284 the way in which the connection is established. Three options are
285 provided:
286 1) Site/socket already connected to DRS as a dummy
287 control connection. (A dummy control connection
288 should not also be the real control connection.)
289 2) Connect via standard ICP. (Only for command no. 6.)
290 3) Connect directly via STR, RTS.
291
292 EXAMPLE CONNECTION CONFIGURATIONS
293
294 There are basically two modes of DRS operation: 1) the user wishes to
295 establish a DRS UC/SC connection(s) between two programs and 2) the
296 user wants to establish the same connection(s) where he (his
297 terminal) is at the end of the UC or the SC. The latter case is
298 appropriate when the user wishes to interact from his terminal with
299 the serving process (e.g., a logger).
300
301 In the first case (Fig. 1, where the originating user is either a
302 terminal or a program) the user issues the appropriate CONNECT
303 command. The UC/SC can be simplex or duplex.
304
305 The second case has two possible configurations, shown in Figs. 3 and
306 4.
307
308 +--------+ CC +--------+ +------+
309 | +------+ | SC | |
310 +------+ /| TELNET | UC | DRS +------+ SP |
311 | |/ | +------+ | | |
312 | USER | /+--------+ +--------+ +------+
313 | |/
314 +------+
315
316 Figure 3. Use of Dummy Control Connection
317
318 +--------+
319 +------+ /| USER | CC +--------+ +------+
320 | |/ | SIDE +------+ | SC | |
321 | USER | +--------+ UC | DRS +------+ SP |
322 | |\ | SERVING+------+ | | |
323 +------+ \| SIDE | +--------+ +------+
324 +--------+
325
326 Figure 4. Use of Server TELNET
327
328
329
330
331
332 <span class="grey">Anderson, et al. [Page 6]</span></pre>
333 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-7" ></span>
334 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
335
336
337 In Fig. 3 the user instructs his TELNET to make two duplex
338 connections to DRS. One is used for control information (the CC) and
339 the other is a dummy. When he issues the CONNECT he references the
340 dummy duplex connection (UC) using the "already connected" option.
341
342 In Fig. 4 the user has his TELNET (user side) call the DRS. When he
343 issues the CONNECT the DRS calls the TELNET (server side) which
344 accepts the call on behalf of the console. This distinction is known
345 only to the user since to the DRS the configuration in Fig. 4 appears
346 identical to that in Fig. 1. Two points should be noted:
347
348 1) TELNET protocol is needed only to define forms and direct
349 connections. It is not required for the using and serving
350 processes.
351 2) The using and serving processes need only a minimum of
352 modification for Network use, i.e., an NCP interface.
353
354
355 III. THE FORM MACHINE
356
357 INPUT/OUTPUT STREAMS AND FORMS
358
359 This section describes the syntax and semantics of forms that specify
360 the data reconfigurations. The Form Machine gets an input stream,
361 reformats the input stream according to a form describing the
362 reconfiguration, and emits the reformatted data as an output stream.
363
364 In reading this section it will be helpful to envision the
365 application of a form to the data stream as depicted in Fig. 5. An
366 input stream pointer identifies the position of data (in the input
367 stream) that is being analyzed at any given time by a part of the
368 form. Likewise, an output stream pointer locates data being emitted
369 in the output stream.
370
371
372 /\/\ /\/\
373 ^ | | FORM | | ^
374 | | | ----------------- | | |
375 | | | +- ----------------- -+ | | |
376 | | | | CURRENT PART OF | | | |
377 INPUT | |&lt;= CURRENT &lt; ----------------- &gt; CURRENT =&gt; | | OUTPUT
378 STREAM | | POINTER | FORM BEING APPLIED | POINTER | | STREAM
379 | | +- ----------------- -+ | |
380 | | ----------------- | |
381 | | ----------------- | |
382 | | ----------------- | |
383 \/\/ \/\/
384 Figure 5. Application of Form to Data Streams
385
386
387
388 <span class="grey">Anderson, et al. [Page 7]</span></pre>
389 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-8" ></span>
390 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
391
392
393 FORM MACHINE BNF SYNTAX
394
395 form ::= rule | rule form
396
397 rule ;;= label inputstream outputstream ;
398
399 label ::= INTEGER | &lt;null&gt;
400
401 inputstream ::= terms | &lt;null&gt;
402
403 terms ::= term | terms , term
404
405 outputstream ::= : terms | &lt;null&gt;
406
407 term ::= identifier | identifier descriptor |
408 descriptor | comparator
409
410 identifier ::= an alpha character followed by 0 to 3
411 alphamerics
412
413 descriptor ::= (replicationexpression , datatype ,
414 valueexpression , lengthexpression control)
415
416 comparator ::= (value connective value control) |
417 (identifier .&lt;=&gt;. control)
418
419 replicationexpression ::= arithmeticexpression | &lt;null&gt;
420
421 datatype ::= B | O | X | E | A
422
423 valueexpression ::= value | &lt;null&gt;
424
425 lengthexpression ::= # | arithmeticexpression | &lt;null&gt;
426
427 connective ::= .LE. | .LT. | .GE. | .GT. | .EQ. | .NE.
428
429 value ::= literal | arithmeticexpression
430
431 arithmeticexpression ::= primary | primary operator
432 arithmeticexpression
433
434 primary ::= identifier | L(identifier) | V(identifier) |
435 INTEGER
436
437 operator ::= + | - | * | /
438
439 literal ::= literaltype "string"
440
441
442
443
444 <span class="grey">Anderson, et al. [Page 8]</span></pre>
445 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-9" ></span>
446 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
447
448
449 literaltype ::= B | O | X | E | A
450
451 string ::= from 0 to 256 characters
452
453 control ::= : options | &lt;null&gt;
454
455 options ::= S(where) | F(where) | U(where) |
456 S(where) , F(where) |
457 F(where) , S(where)
458
459 where ::= arithmeticexpression | R(arithmeticexpression)
460
461
462
463 ALTERNATE SPECIFICATION OF FORM MACHINE SYNTAX
464
465 infinity
466 form ::= {rule}
467 1
468 1 1 1
469 rule ::= {INTEGER} {terms} {:terms} ;
470 0 0 0
471 infinity
472 terms ::= term {,term}
473 0
474 1
475 term ::= identifier | {identifier} descriptor
476 0
477 | comparator
478 1
479 descriptor ::= ({arithmeticexpression} , datatype ,
480 0
481 1 1 1
482 {value} , {lengthexpression} {:options}
483 0 0 0
484 1
485 comparator ::= (value connective value {:options} ) |
486 0
487 1
488 (identifier .&lt;=. value {:options} )
489 0
490 connective ::= .LE. | .LT. | .GE. | .GT. | .EQ. | .NE.
491
492 lengthexpression ::= # | arithmeticexpression
493
494 datatype ::= B | O | X | E | A
495
496 value ::= literal | arithmeticexpression
497
498
499
500 <span class="grey">Anderson, et al. [Page 9]</span></pre>
501 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-10" ></span>
502 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
503
504
505 infinity
506 arithmeticexpression ::= primary {operator primary}
507 0
508 operator ::= + | - | * | /
509
510 primary ::= identifier | L(identifier) |
511 V(identifier) | INTEGER
512 256
513 literal ::= literaltype "{CHARACTER} "
514 0
515 literaltype ::= B | O | X | A | E
516 1
517 options ::= S(where) {,F(where)} |
518 0
519 1
520 F(where) {,S(where)} | U(where)
521 0
522
523 where ::= arithmeticexpression |
524 R(arithmeticexpression)
525 3
526 identifier ::= ALPHABETIC {ALPHAMERIC}
527 0
528
529 FORMS
530
531 A form is an ordered set of rules.
532
533 form ::= rule | rule form
534
535 The current rule is applied to the current position of the input
536 stream. If the (input stream part of a) rule fails to correctly
537 describe the contents of the current input then another rule is made
538 current and applied to the current position of the input stream. The
539 next rule to be made current is either explicitly specified by the
540 current term in the current rule or it is the next sequential rule by
541 default. Flow of control is more fully described under TERM AND RULE
542 SEQUENCING.
543
544 If the (input stream part of a) rule succeeds in correctly describing
545 the current input stream, then some data may be emitted at the
546 current position in the output stream according to the rule. The
547 input and output stream pointers are advanced over the described and
548 emitted data, respectively, and the next rule is applied to the now
549 current position of the input stream.
550
551 Application of the form is terminated when an explicit return
552 (R(arithmeticexpression)) is encountered in a rule. The user and
553
554
555
556 <span class="grey">Anderson, et al. [Page 10]</span></pre>
557 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-11" ></span>
558 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
559
560
561 server connections are closed and the return code
562 (arithmeticexpression) is sent to the originating user.
563
564 RULES
565
566 A rule is a replacement, comparison, and/or an assignment operation
567 of the form shown below.
568
569 rule ::= label inputstream outputstream ;
570
571 A label is the name of a rule and it exists so that the rule may be
572 referenced elsewhere in the form for explicit rule transfer of
573 control. Labels are of the form below.
574
575 label ::= INTEGER | &lt;null&gt;
576
577 The optional integer labels are in the range 0 &gt;= INTEGER &gt;= 9999.
578 The rules need not be labeled in ascending numerical order.
579
580 TERMS
581
582 The inputstream (describing the input stream to be matched) and the
583 outputstream (describing data to be emitted in the output stream)
584 consist of zero or more terms and are of the form shown below.
585
586 inputstream ::= terms | &lt;null&gt;
587 outputstream ::= :terms | &lt;null&gt;
588 terms ::= term | terms , term
589
590 Terms are of one of four formats as indicated below.
591
592 term ::= identifier | identifier descriptor |
593 descriptor | comparator
594
595 Term Format 1
596
597 The first term format is shown below.
598
599 identifier
600
601 The identifier is a symbolic reference to a previously identified
602 term (term format 2) in the form. It takes on the same attributes
603 (value, length, type) as the term by that name. Term format 1 is
604 normally used to emit data in the output stream.
605
606 Identifiers are formed by an alpha character followed by 0 to 3
607 alphameric characters.
608
609
610
611
612 <span class="grey">Anderson, et al. [Page 11]</span></pre>
613 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-12" ></span>
614 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
615
616
617 Term Format 2
618
619 The second term format is shown below.
620
621 identifier descriptor
622
623 Term format 2 is generally used as an input stream term but can be
624 used as an output stream term.
625
626 A descriptor is defined as shown below.
627
628 descriptor ::= (replicationexpression, datatype,
629 valueexpression, lengthexpression
630 control)
631
632 The identifier is the symbolic name of the term in the usual
633 programming language sense. It takes on the type, length, and value
634 attributes of the term and it may be referenced elsewhere in the
635 form.
636
637 The replication expression is defined below.
638
639 replicationexpression ::= arithmeticexpression | &lt;null&gt;
640 arithmeticexpression ::= primary | primary operator
641 arithmeticexpression
642 operator ::= + | - | * | /
643 primary ::= identifier | L(identifier) | V(identifier) |
644 INTEGER
645
646 The replication expression is a repeat function applied to the
647 combined data type and value expression. It expresses the number of
648 times that the value (of the data type/value expression) is to be
649 repeated within the field length denoted by the data type/length
650 expression.
651
652 A null replication expression has the value of one. Arithmetic
653 expressions are evaluated from left-to-right with no precedence. (It
654 is anticipated that this interpretation might be changed, if
655 necessary.)
656
657 The L(identifier) is a length operator that generates a 32-bit binary
658 integer corresponding to the length of the term named. The
659 V(identifier) is a value operator that generates a 32-bit binary
660 integer corresponding to the value of the term named. (See
661 Restrictions and Interpretations of Term Functions.) The value
662 operator is intended to convert character strings to their numerical
663 correspondents.
664
665
666
667
668 <span class="grey">Anderson, et al. [Page 12]</span></pre>
669 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-13" ></span>
670 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
671
672
673 The data type is defined below.
674
675 datatype ::= B | O | X | E | A
676
677 The data type describes the kind of data that the term represents.
678 (It is expected that additional data types, such as floating point
679 and user-defined types, will be added as needed.)
680
681 Data Type Meaning Unit Length
682
683 B Bit string 1 bit
684 O Bit string 3 bits
685 X Bit string 4 bits
686 E EBCDIC character 8 bits
687 A Network ASCII character 8 bits
688
689 The value expression is defined below.
690
691 valueexpression ::= value | &lt;null&gt;
692 value ::= literal | arithmeticexpression
693 literal ::= literaltype "string"
694 literaltype ::= B | O | X | E | A
695
696 The value expression is the unit value of a term expressed in the
697 format indicated by the data type. It is repeated according to the
698 replication expression, in a field whose length is constrained by the
699 length expression.
700
701 A null value expression in the input stream defaults to the data
702 present in the input stream. The data must comply with the datatype
703 attribute, however.
704
705 A null value expression generates padding according to Restrictions
706 and Interpretations of Term Functions.
707
708 The length expression is defined below.
709
710 lengthexpression ::= # | arithmeticexpression | &lt;null&gt;
711
712 The length expression states the length of the field containing the
713 value expression as expanded by the replication expression. If the
714 value of the length expression is less then the length implied by the
715 expanded value expression, then the expanded value expression is
716 truncated, see Restrictions and Interpretations of Term Functions.
717
718 The terminal symbol # means an arbitrary length, explicitly
719 terminated by the value of the next term. The # is legal only in the
720 input stream and not in the output stream.
721
722
723
724 <span class="grey">Anderson, et al. [Page 13]</span></pre>
725 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-14" ></span>
726 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
727
728
729 If the length expression is less than or equal to zero, the term
730 succeeds but the appropriate stream pointer is not advanced.
731 Positive lengths cause the appropriate stream pointer to be advanced
732 if the term otherwise succeeds.
733
734 Control is defined under TERM AND RULE SEQUENCING.
735
736 Term Format 3
737
738 Term format 3 is shown below.
739
740 descriptor
741
742 It is identical to term format 2 with the omission of the identifier.
743 Term format 3 is generally used in the output stream. It is used in
744 the input stream where input data is to be passed over but not
745 retained for emission or later reference.
746
747 Term Format 4
748
749 The fourth term format is shown below.
750
751 comparator ::= (value connective value control) |
752 (identifier .&lt;=. value control)
753 value ::= literal | arithmeticexpression
754 literal ::= literaltype "string"
755 literaltype ::= B | O | X | E | A
756 string ::= from 0 to 256 characters
757 connective ::= .LE. | .LT. | .GE. | .GT. | .EQ. | .NE.
758
759 The fourth term format is used for assignment and comparison.
760
761 The assignment operator .&lt;=. assigns the value to the identifier.
762 The connectives have their usual meaning. Values to be compared must
763 have the same type and length attributes or an error condition arises
764 and the form fails.
765
766 The Application of a Term
767
768 The elements of a term are applied by the following sequence of
769 steps.
770
771 1. The data type and value expression together specify a unit
772 value, call it x.
773
774 2. The replication expression specifies the number of times x
775 is to be repeated (or copied) in concatenated fashion. The
776 value of the concatenated xs becomes, say, y of length L1.
777
778
779
780 <span class="grey">Anderson, et al. [Page 14]</span></pre>
781 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-15" ></span>
782 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
783
784
785 3. The data type and the length expression together specify a
786 field length of the input area (call it L2) that begins at
787 the current stream pointer position.
788
789 4. The value of y is truncated to y' if L1 &gt; L2. Call the
790 truncated length L1'.
791
792 5. If the term is an input stream term, then the value y' of
793 length L1' is compared to the input value beginning at the
794 current input pointer position.
795
796 6. If the values are identical over the length L1' then the
797 input value of length L2 (may be greater than L1') starting
798 at the current pointer position in the input area, becomes
799 the value of the term.
800
801 In an output stream term, the procedure is the same except that the
802 source of input is the value of the term(s) named in the value
803 expression and the data is emitted in the output stream.
804
805 The above procedure is modified to include a one term look-ahead
806 where lengths are indefinite because of the arbitrary symbol, #.
807
808 Restrictions and Interpretations of Term Functions
809
810 1. Terms specifying indefinite lengths, through the use of the #
811 symbol must be separated by some type-specific data such as a
812 literal. (A literal isn't specifically required, however. An
813 arbitrary number of ASCII characters could be terminated by a
814 non-ASCII character.) # is legal only in the input stream, not
815 in the output stream.
816
817 2. Truncation and padding is as follows:
818 a) Character to character (A &lt;--&gt; E) conversion is left
819 justified and truncated or padded on the right with blanks.
820 b) Character to numeric and numeric to numeric conversions are
821 right-justified and truncated or padded on the left with
822 zeros.
823 c) Numeric to character conversion is right-justified and
824 left-padded with blanks.
825
826 3. The following are ignored in a form definition over the control
827 connection.
828 a) TAB, carriage return, etc.
829 b) blanks except within quotes.
830 c) /* string */ is treated as comments except within quotes.
831
832 4. The following defaults prevail where the term part is omitted.
833
834
835
836 <span class="grey">Anderson, et al. [Page 15]</span></pre>
837 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-16" ></span>
838 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
839
840
841 a) The replication expression defaults to one.
842 b) The data type defaults to type B.
843 c) The value expression of an input stream term defaults to
844 the value found in the input stream, but the input stream
845 must conform to data type and length expression. The value
846 expression of an output stream term defaults to padding
847 only.
848 d) The length expression defaults to the size of the quantity
849 determined by replication expression, data type, and value
850 expression.
851 e) Control defaults to the next sequential term if a term is
852 successfully applied; else control defaults to the next
853 sequential rule. If _where_ evaluates to an undefined
854 _label_ the form fails.
855
856 5. Arithmetic expressions are evaluated left-to-right with no
857 precedence.
858
859 6. The following limits prevail.
860
861 a) Binary lengths are &lt;= 32 bits
862 b) Character strings are &lt;= 256 8-bit characters
863 c) Identifier names are &lt;= 4 characters
864 d) Maximum number of identifiers is &lt;= 256
865 e) Label integers are &gt;= 0 and &lt;= 9999
866
867 7. Value and length operators product 32-bit binary integers. The
868 value operator is currently intended for converting A or E type
869 decimal character strings to their binary correspondents. For
870 example, the value of E'12' would be 0......01100. The value
871 of E'AB' would cause the form to fail.
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892 <span class="grey">Anderson, et al. [Page 16]</span></pre>
893 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-17" ></span>
894 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
895
896
897 TERM AND RULE SEQUENCING
898
899 Sequencing may be explicitly controlled by including control in a
900 term.
901
902 control ::= :options | &lt;null&gt;
903 options ::= S(where) | F(where) | U(where)
904 S(where) , F(where) |
905 F(where) , S(where)
906
907 where ::= arithmeticexpression | R(arithmeticexpression)
908
909 S, F, and U denote success, fail, and unconditional transfers,
910 respectively. _Where_ evaluates to a _rule_ label, thus transfer can
911 be effected from within a rule (at the end of a term) to the
912 beginning of another rule. R means terminate the form and return the
913 evaluated expression to the initiator over the control connection (if
914 still open).
915
916 If terms are not explicitly sequenced, the following defaults
917 prevail.
918
919 1) When a term fails go to the next sequential rule.
920 2) When a term succeeds go to the next sequential
921 term within the rule.
922 (3) At the end of a rule, go to the next sequential
923 rule.
924
925 Note in the following example, the correlation between transfer of
926 control and movement of the input pointer.
927
928 1 XYZ(,B,,8:S(2),F(3)) : XYZ ;
929 2 . . . . . . .
930 3 . . . . . . .
931
932 The value of XYZ will never be emitted in the output stream since
933 control is transferred out of the rule upon either success or
934 failure. If the term succeeds, the 8 bits of input will be assigned
935 as the value of XYZ and rule 2 will then be applied to the same input
936 stream data. That is, since the complete rule 1 was not successfully
937 applied, then the input stream pointer is not advanced.
938
939
940
941
942
943
944
945
946
947
948 <span class="grey">Anderson, et al. [Page 17]</span></pre>
949 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-18" ></span>
950 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
951
952
953 IV. EXAMPLES
954
955 REMARKS
956
957 The following examples (forms and also single rules) are simple
958 representative uses of the Form Machine. The examples are expressed
959 in a term-per-line format only to aid the explanation. Typically, a
960 single rule might be written as a single line.
961
962 FIELD INSERTION
963
964 To insert a field, separate the input into the two terms to allow the
965 inserted field between them. For example, to do line numbering for a
966 121 character/line printer with a leading carriage control character,
967 use the following form.
968
969 (NUMB.&lt;=&gt;.1); /*initialize line number counter to one*/
970 1 CC(,E,,1:F(R(99))), /*pick up control character and save
971 as CC*/
972 /*return a code of 99 upon exhaustion*/
973 LINE(,E,,121 : F(R(98))) /*save text as LINE*/
974 :CC, /*emit control character*/
975 (,E,NUMB,2), /*emit counter in first two columns*/
976 (,E,E".",1), /*emit period after line number*/
977 (,E,LINE,117), /*emit text, truncated in 117 byte field*/
978 (NUMB.&lt;=.NUMB+1:U(1)); /*increment line counter and go to
979 rule one*/;;
980
981 DELETION
982
983 Data to be deleted should be isolated as separate terms on the left,
984 so they may be omitted (by not emitting them) on the right.
985
986 (,B,,8), /*isolate 8 bits to ignore*/
987 SAVE(,A,,10) /*extract 10 ASCII characters from
988 input stream*/
989 :(,E,SAVE,); /*emit the characters in SAVE as EBCDIC
990 characters whose length defaults to the
991 length of SAVE, i.e., 10, and advance to
992 the next rule*/
993
994 In the above example, if either input stream term fails,
995 the next sequential rule is applied.
996
997 VARIABLE LENGTH RECORDS
998
999 Some devices, terminals and programs generate variable length
1000 records. To following rule picks up variable length EBCDIC records
1001
1002
1003
1004 <span class="grey">Anderson, et al. [Page 18]</span></pre>
1005 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-19" ></span>
1006 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
1007
1008
1009 and translates them to ASCII.
1010
1011 CHAR(,E,,#), /*pick up all (an arbitrary number of)
1012 EBCDIC characters in the input stream*/
1013 (,X,X"FF",2) /*followed by a hexadecimal literal,
1014 FF (terminal signal)*/
1015 :(,A,CHAR,), /*emit them as ASCII*/
1016 (,X,X"25",2); /*emit an ASCII carriage return*/
1017
1018 STRING LENGTH COMPUTATION
1019
1020 It is often necessary to prefix a length field to an arbitrarily long
1021 character string. The following rule prefixes an EBCDIC string with
1022 a one-byte length field.
1023
1024 Q(,E,,#), /*pick up all EBCDIC characters*/
1025 TS(,X,X"FF",2) /*followed by a hexadecimal literal, FF*/
1026 :(,B,L(Q)+2,8), /*emit the length of the characters
1027 plus the length of the literal plus
1028 the length of the count field itself,
1029 in an 8-bit field*/
1030 Q, */emit the characters*/
1031 TS; */emit the terminal*/
1032
1033 TRANSPOSITION
1034
1035 It is often desirable to reorder fields, such as the following
1036 example.
1037
1038 Q(,E,,20), R(,E,,10) , S(,E,,15), T(,E,,5) : R, T, S, Q ;
1039
1040 The terms are emitted in a different order.
1041
1042 CHARACTER PACKING AND UNPACKING
1043
1044 In systems such as HASP, repeated sequences of characters are packed
1045 into a count followed by the character, for more efficient storage
1046 and transmission. The first form packs multiple characters and the
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060 <span class="grey">Anderson, et al. [Page 19]</span></pre>
1061 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-20" ></span>
1062 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
1063
1064
1065 second unpacks them.
1066 /*form to pack EBCDIC streams*/
1067 /*returns 99 if OK, input exhausted*/
1068 /*returns 98 if illegal EBCDIC*/
1069 /*look for terminal signal FF which is not a legal EBCDIC*/
1070 /*duplication count must be 0-254*/
1071 1 (,X,X"FF",2 : S(R(99))) ;
1072 /*pick up the EBCDIC and initialize count/*
1073 CHAR(,E,,1 : F(R(98))) , (CNT .&lt;=. 1) ;
1074 /*count consecutive EBCDICs like CHAR*/
1075 2 (,E,CHAR,1 : F(3)) , (CNT .&lt;=. CNT+1 : U(2)) ;
1076 /*emit count and current character*/
1077 3 : (,B,CNT,8), CHAR, (:U(1));
1078 /*end of form*/;;
1079
1080 /*form to unpack EBCDIC streams*/
1081 /*look for terminal*/
1082 1 (,X,X"FF",2 : S(R(99))) ;
1083 /*emit character the number of times indicated*/
1084 /*by the counter contents*/
1085 CNT(,B,,8), CHAR(,E,,1) : (CNT,E,CHAR,CNT:U(1));
1086 /*failure of form*/
1087 (:U(R(98))) ;;
1088
1089
1090 <span class="h2"><a class="selflink" id="appendix-V" href="#appendix-V">V</a>. PROPOSED USES OF DATA RECONFIGURATION SERVICE</span>
1091
1092 The following are some proposed uses of the DRS that were submitted
1093 by the sites indicated.
1094
1095 UCLA
1096 1. Pack/unpack text files.
1097 2. Preprocessor to scan META compiler input.
1098 3. Perhaps graphics.
1099
1100 MIT
1101 1. Reformatting within file transfer service.
1102 2. Character conversions.
1103 3. Possible graphics service (Evans and Sutherland output
1104 format).
1105 4. Reformat arguments of subroutines remote to each other.
1106
1107 U. OF ILLINOIS
1108 1. Dependent upon remote use of DRS for many remote
1109 services.
1110
1111 SDC
1112 1. Would be essential to data transfer in general.
1113
1114
1115
1116 <span class="grey">Anderson, et al. [Page 20]</span></pre>
1117 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-21" ></span>
1118 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
1119
1120
1121 2. Could be used in relation to data management language.
1122
1123 UCSB
1124 1. Checkout of I/O formats of file system.
1125 2. Debugging Network services in general.
1126 3. Mapping their services into future standards.
1127
1128 RAND
1129 1. To describe RJO/RJE message formats at UCSB.
1130 2. To describe RJS message formats at UCLA.
1131 3. To adapt Network to existing services, in general.
1132
1133 MITRE
1134 1. Character conversions.
1135 2. Testing data formats going into data bases for correct
1136 field formatting.
1137
1138 VI. IMPLEMENTATION PLANS
1139
1140 Four sites currently plan to implement and offer the service on an
1141 experimental basis.
1142
1143 1. MIT Implementation of forms interpreter in MIDAS
1144 (assembly). Perhaps Tree Meta compiler of
1145 forms. Implementation on PDP-10.
1146
1147 2. UCLA Implementation on SIGMA-7 employing META-7
1148 to compile forms.
1149
1150 3. UCSB Implementation on 360/75.
1151
1152 4. RAND Initial implementation on 360/65; compiler to be written
1153 in graphics CPS; compiled intermediate forms to be
1154 interpreted by assembler language subroutine. Later
1155 implemented on PDP-10.
1156
1157 In addition to the above sites, the University of Illinois and Mitre
1158 plan to experiment with the service.
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172 <span class="grey">Anderson, et al. [Page 21]</span></pre>
1173 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-22" ></span>
1174 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
1175
1176
1177 APPENDIX A
1178
1179 Note 1 to the DRS Working Group
1180
1181 As you recall, we spent considerable time in discussing the use and
1182 meaning of the arbitrary symbol, #. To summarize, it was clear that
1183 inclusion of the # in both replication and length expressions led to
1184 ambiguities. We settled on its restricted use in the length
1185 expression of an input term, although no one was entirely satisfied
1186 with this definition.
1187
1188 Recently, Jim White has again commented on the #. Jim feels that it
1189 is curious that one can pick up an arbitrary number of EBCDIC
1190 characters, for example, but can't pick up an arbitrary number of
1191 specific EBCDIC characters such as EBCDIC A's. Jim feels that a more
1192 natural way to interpret the length, value, and replication
1193 expressions would be as the IBM OS assembler interprets the
1194 attributes of the pseudo instruction, define constant (CD).
1195
1196 The IBM OS assembler uses the following format.
1197
1198 1 2 3 4
1199 duplication type modifiers nominal value
1200 factor
1201
1202 The duplication factor, if specified, causes the constant to be
1203 generated the number of times indicated by the factor. The type
1204 defines the type of constant being specified. Modifiers describe the
1205 length, scaling, and exponent of the constant. Nominal value
1206 supplies the constant described by the subfields that precede it.
1207
1208 Assume that we use the # only as a duplication factor (replication
1209 expression). Hence, in the example of the form to pack EBCDIC
1210 characters, the counter and looping can be eliminated.
1211
1212 CHAR(,E,,1) ;
1213 LEN(#,#,CHAR,1) : (,B,L(LEN)+1,*) , CHAR ;
1214
1215 The interpretation is that the data type, length expression, and
1216 value expression make up the unit value. This quantity can then be
1217 replicated. As our document now stands, only the data type and value
1218 expression make up the unit value.
1219
1220 The application of a term according to Jim's suggestion is as
1221 follows.
1222 1. The data type, value expression, and length expression together
1223 specify a unit value, call it x.
1224
1225
1226
1227
1228 <span class="grey">Anderson, et al. [Page 22]</span></pre>
1229 <hr class='noprint'/><!--NewPage--><pre class='newpage'><span id="page-23" ></span>
1230 <span class="grey"><a href="./rfc138">RFC 138</a> Data Reconfiguration Service April 1971</span>
1231
1232
1233 2. The replication expression specifies the number of times x is to
1234 be repeated. The value of the concatenated xs becomes y of
1235 length L.
1236 3. If the term is an input stream term then the value beginning at
1237 the current input pointer position.
1238 4. If the input value satisfies the constraints of y over length L
1239 then the input value of length L becomes the value of the term.
1240
1241 Note 2 to the DRS Working Group
1242
1243 There has been recent debate of whether the input pointer should be
1244 advanced upon successful completion of a rule (as it now is defined)
1245 or upon successful completion of each term. See the example on page
1246 22. If the input pointer is advanced upon successful completion of a
1247 term, then rules become equivalent to terms.
1248
1249 I would like to for us to discuss at the SJCC both the term
1250 attributes and the input pointer advance issues.
1251
1252 John
1253
1254
1255 [ This RFC was put into machine readable form for entry ]
1256 [ into the online RFC archives by Katsunori Tanaka 4/99 ]
1257
1258