1 .TH "sane\-umax_pp" "5" "14 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-umax_pp
3 .SH "NAME"
4 sane\-umax_pp \- SANE backend for Umax Astra parallel port flatbed scanners
5 .SH "DESCRIPTION"
6 The
7 .B sane\-umax_pp
8 library implements a SANE (Scanner Access Now Easy) backend that
9 provides access to Umax parallel port flatbed scanners. The
10 following scanners work with this backend:
11 .PP
12 .RS
13 Model:
14 .br
15 \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
16 .br
17 Astra 610P
18 .br
19 Astra 1220P
20 .br
21 HP3200C
22 .br
23 Astra 1600P
24 .br
25 Astra 2000P
26 .br
27 Genius ColorPage-Life Pro
28 .br
29 .RE
30 .PP
31 This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200 for 1220P/1600P/2000P
32 dpi scan resolutions, and 75x75, 150x150, 300x300 and 300x600 for 610P. In color and gray
33 levels, there is a software lineart mode.
34 .PP
35 The new generation models share a newer version of the 610P ASIC embedded in an EPAT chip.
36 Only parts such as CCD and ADC change from
37 one to another. They even all reports being UMAX Astra 1220P via IEEE1284.
38 There isn't a software method to recognize them properly. Under windows, model is
39 set by the driver installed, regardless of the hardware.
40 .PP
41 .TP
42 .B EPP/ECP MODES ONLY
43 The current version of the backend uses only EPP or ECP mode to communicate
44 with the scanner. PS/2 mode isn't implemented. The 610P only use SPP. It is
45 recommended that you set your parallel port to EPP in BIOS with the current
46 version of this
47 backend. You can leave it to ECP or ECP+EPP, but in this case you may not use
48 ppdev but only direct hardware access if you have to use ECP. ECPEPP will only
49 work if you use a 2.4 or 2.6 kernel with ppdev character device support.
50 .PP
51 This backend does support parport sharing only
52 .I
53 if you have a kernel with ppdev support.
54 .I
55 .PP
56 Note that if you don't use the ppdev character device, the backend
57 needs to run as root. To allow user access to the scanner
58 run the backend through the network interface (see
59 .BR saned (8)
60 and
61 .BR sane\-net (5)).
62 A more relaxed solution (security wise) is to add suid bit to the frontend
63 (see
64 .BR chmod (1)).
65 The backend drops root privileges as soon as it can, right after gaining direct
66 access to I/O ports, which lessen risks of being root.
67
68 .SH "DEVICE NAMES"
69 This backend expects device names of the form:
70 .PP
71 .RS
72 .I port value
73 .RE
74 .PP
75 Where
76 \fBvalue\fR is:
77
78 .RS
79 .TP
80 auto
81 autodetect all parallel ports and probe
82 them for scanner
83 .TP
84 safe\-auto
85 autodetect all parallel ports and probe
86 them for scanner, but does not try direct
87 hardware access
88 .TP
89 .I /dev/ppi0
90 uses *BSD ppi device, depending on the
91 number of available parallel port, you
92 have to use
93 .IR /dev/ppi1 ,
94 .IR /dev/ppi2 ", ..."
95 .TP
96 .I /dev/parport0
97 uses Linux ppdev device, depending on the
98 number of available parallel port, you
99 have to use
100 .IR /dev/parport1 ,
101 .IR /dev/parport2 ", ..."
102 .TP
103 0x378
104 does direct hardware access on the given
105 address. Usual values are 0x378, 0x278, 0x3BC.
106 In this case, you have to run the backend as
107 root (*BSD and Linux), or with 'IOPL=yes' on
108 OS/2
109 .PP
110 .RE
111 \fBNOTE:\fR in all cases, you must have sufficient privileges
112 to get access to the chosen device or address. Depending on the
113 security settings, devices may not be available for all users.
114 You have to change permissions on the
115 .I /dev/ppi*
116 or
117 .I /dev/parport*
118 devices.
119 .PP
120 .RE
121 You can rename any device using the
122 .PP
123 .RS
124 .I name devname
125 .br
126 .I model model
127 .br
128 .I vendor vendor
129 .RE
130 .PP
131 options. These options apply to the last port option.
132
133 .SH "CONFIGURATION"
134 Please make sure to edit
135 .I umax_pp.conf
136 .B before
137 you use the backend.
138 .PP
139 The contents of the
140 .I umax_pp.conf
141 file is a list of options and device names that correspond to Umax
142 scanners. Empty lines and lines starting with a hash mark (#) are
143 ignored.
144 .PP
145 The eight options supported are
146 .BR red\-gain ,
147 .BR green\-gain ,
148 .BR blue\-gain ,
149 .BR red\-offset ,
150 .BR green\-offset ,
151 .BR blue\-offset ,
152 .BR astra ,
153 and
154 .BR buffer .
155
156 Options
157 .BR red\-gain ,
158 .B green\-gain
159 and
160 .B blue\-gain
161 allow you to adjust the sensitivity of your scanner for the given color. Values
162 range from 0 (lowest gain) to 15 (highest). If the advanced option "Gain" isn't
163 checked in the frontend, the backend does automatic gain calibration, and do not use
164 user provided values.
165
166 .PP
167
168 Options
169 .BR red\-offset ,
170 .B green\-offset
171 and
172 .B blue\-offset
173 allow you to adjust the offset of your scanner for the given color. Values
174 range from 0 (lowest offset) to 15 (highest).
175 .PP
176
177 Option
178 .B astra
179 allows you to change the model of your scanner. Current auto detection is based
180 on side effects on scanning when using 1220P command set on other models, so
181 it may fail on unknown hardware combination. Valid values are 610, 1220, 1600
182 and 2000. It is useful only when autodetection fails to detect properly
183 your scanner model. If your scanner work properly but is reported wrongly,
184 let it be that way.
185 The only valid case to change the model is when your scanner produces "black" or
186 "inverted" scans. In this case you can put the model. Be aware that it will
187 prevent scanner model autodetection.
188 .PP
189
190 Option
191 .B buffer
192 allows you to change the size of the scan buffer. The size must be specified in
193 bytes. The default value is 2 megabytes. Decreasing this value will improve the
194 smoothness of progress bar in the frontend, but will stall the
195 scan more often.
196
197 .PP
198
199
200
201 .SH "FILES"
202 .TP
203 .I /etc/sane.d/umax_pp.conf
204 The backend configuration file (see also description of
205 .B SANE_CONFIG_DIR
206 below).
207 .TP
208 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-umax_pp.a
209 The static library implementing this backend.
210 .TP
211 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-umax_pp.so
212 The shared library implementing this backend (present on systems that
213 support dynamic loading).
214
215 .SH "ENVIRONMENT"
216 .TP
217 .B SANE_CONFIG_DIR
218 This environment variable specifies the list of directories that may
219 contain the configuration file. On *NIX systems, the directories are
220 separated by a colon (`:'), under OS/2, they are separated by a
221 semi-colon (`;'). If this variable is not set, the configuration file
222 is searched in two default directories: first, the current working
223 directory (".") and then in
224 .IR /etc/sane.d .
225 If the value of the
226 environment variable ends with the directory separator character, then
227 the default directories are searched after the explicitly specified
228 directories. For example, setting
229 .B SANE_CONFIG_DIR
230 to "/tmp/config:" would result in directories
231 .IR tmp/config ,
232 .IR . ,
233 and
234 .I /etc/sane.d
235 being searched (in this order).
236 .TP
237 .B SANE_DEBUG_UMAX_PP
238 If the library was compiled with debug support enabled, this
239 environment variable controls the debug level for this backend. E.g.,
240 a value of 128 requests all debug output to be printed. Smaller
241 levels reduce verbosity.
242
243 .PP
244 .RS
245 .ft CR
246 .nf
247 level debug output
248 \-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
249 0 nothing
250 1 errors
251 2 warnings & minor errors
252 3 additional information
253 4 debug information
254 5 code flow (not supported yet)
255 6 special debug information
256 .fi
257 .ft R
258 .RE
259 .PP
260 .TP
261 .B SANE_DEBUG_UMAX_PP_LOW
262 This variable sets the debug level for the SANE interface for the Umax
263 ASIC. Note that enabling this will spam your terminal with some
264 million lines of debug output.
265
266 .PP
267 .RS
268 .ft CR
269 .nf
270 level debug output
271 \-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
272 0 nothing
273 1 errors
274 8 command blocks
275 16 detailed code flow
276 32 dump datafiles
277 255 everything
278 .fi
279 .ft R
280 .RE
281 .PP
282
283 .PP
284 .SH "SEE ALSO"
285 .BR sane (7),
286 .BR sane\-net (5),
287 .BR saned (8)
288
289 .TP
290 For latest bug fixes and information see
291 .I http://umax1220p.sourceforge.net/
292
293 .SH "AUTHOR"
294 St\['e]phane Voltz
295 .RI < [email protected] >
296
297 .SH "CREDITS"
298 Support for the 610P has been made possible thank to an hardware donation
299 by William Stuart.
300
301 .SH "BUG REPORTS"
302 If something doesn't work, please contact me. But I need some information about
303 your scanner to be able to help you...
304
305 .TP
306 .I SANE version
307 Run
308 .I "scanimage \-V"
309 to determine this
310 .TP
311 .I the backend version and your scanner hardware
312 Run
313 .I "SANE_DEBUG_UMAX_PP=255 scanimage \-L 2>log"
314 as root. If you don't get any output
315 from the
316 .B sane\-umax_pp
317 backend, make sure a line "umax_pp" is included into your
318 .I /etc/sane.d/dll.conf
319 file.
320 If your scanner isn't detected, make sure you've defined the right port address, or the
321 correct device
322 in your
323 .I umax_pp.conf
324 file.
325 .TP
326 .I the name of your scanner/vendor
327 also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
328 .TP