| 1 |
.TH sane\-ma1509 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-ma1509 |
| 3 |
.SH NAME |
| 4 |
sane\-ma1509 \- SANE backend for Mustek BearPaw 1200F USB scanner |
| 5 |
.SH DESCRIPTION |
| 6 |
The |
| 7 |
.B sane\-ma1509 |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that provides |
| 9 |
access to the Mustek BearPaw 1200F USB flatbed scanner. This scanner is based |
| 10 |
on the MA-1509 chipset. Other scanners that use this chip (if they exist) may |
| 11 |
also work. |
| 12 |
.PP |
| 13 |
This backend is ALPHA software. Be careful and remove the power plug |
| 14 |
immediately if your hear unusual noises. |
| 15 |
.PP |
| 16 |
More details can be found on the |
| 17 |
.B sane\-ma1509 |
| 18 |
backend homepage |
| 19 |
.IR http://www.meier\-geinitz.de/sane/ma1509\-backend/ . |
| 20 |
.PP |
| 21 |
Other Mustek USB scanners are supported by the |
| 22 |
.BR sane\-mustek_usb (5), |
| 23 |
.BR sane\-gt68xx (5) |
| 24 |
and |
| 25 |
.BR sane\-plustek (5) |
| 26 |
backends. |
| 27 |
.PP |
| 28 |
This backend can only work with scanners that are already detected by the |
| 29 |
operating system. See |
| 30 |
.BR sane\-usb (5) |
| 31 |
for details. |
| 32 |
.PP |
| 33 |
If you own a scanner other than the Mustek BearPaw 1200F that works with this |
| 34 |
backend, please let me know this by sending the scanner's exact model name and |
| 35 |
the USB vendor and device ids (e.g. from |
| 36 |
.I /proc/bus/usb/devices |
| 37 |
or syslog) to me. |
| 38 |
|
| 39 |
.SH "DEVICE NAMES" |
| 40 |
This backend expects device names of the form: |
| 41 |
.PP |
| 42 |
.RS |
| 43 |
.I special |
| 44 |
.RE |
| 45 |
.PP |
| 46 |
Where |
| 47 |
.I special |
| 48 |
is a path-name for the special device that corresponds to a USB scanner. |
| 49 |
With Linux, such a device name could be |
| 50 |
.I /dev/usb/scanner0 |
| 51 |
or |
| 52 |
.IR libusb:001:002 , |
| 53 |
for example. |
| 54 |
.PP |
| 55 |
|
| 56 |
.SH CONFIGURATION |
| 57 |
The contents of the |
| 58 |
.I ma1509.conf |
| 59 |
file is a list of options and device names that correspond to Mustek BearPaw |
| 60 |
1200F scanners. Empty lines and lines starting with a hash mark (#) are |
| 61 |
ignored. |
| 62 |
.PP |
| 63 |
Instead of using the device name, the scanner can be autodetected by |
| 64 |
.B "usb vendor_id product_id" |
| 65 |
statements which are already included into |
| 66 |
.IR ma1509.conf . |
| 67 |
This is only supported with Linux 2.4.8 and higher and all systems that |
| 68 |
support libsub. "vendor_id" and "product_id" are hexadecimal numbers that |
| 69 |
identify the scanner. If this doesn't work, a device name must be placed in |
| 70 |
.I ma1509.conf |
| 71 |
as described above. |
| 72 |
.PP |
| 73 |
To set the time the lamp needs for warm-up, use |
| 74 |
.B option |
| 75 |
.B warmup-time |
| 76 |
in |
| 77 |
.IR ma1509.conf . |
| 78 |
The time is given in seconds after the option. The default is 30 seconds. |
| 79 |
.SH FILES |
| 80 |
.TP |
| 81 |
.I /etc/sane.d/ma1509.conf |
| 82 |
The backend configuration file (see also description of |
| 83 |
.B SANE_CONFIG_DIR |
| 84 |
below). |
| 85 |
.TP |
| 86 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-ma1509.a |
| 87 |
The static library implementing this backend. |
| 88 |
.TP |
| 89 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-ma1509.so |
| 90 |
The shared library implementing this backend (present on systems that |
| 91 |
support dynamic loading). |
| 92 |
.SH ENVIRONMENT |
| 93 |
.TP |
| 94 |
.B SANE_CONFIG_DIR |
| 95 |
This environment variable specifies the list of directories that may |
| 96 |
contain the configuration file. On *NIX systems, the directories are |
| 97 |
separated by a colon (`:'), under OS/2, they are separated by a |
| 98 |
semi-colon (`;'). If this variable is not set, the configuration file |
| 99 |
is searched in two default directories: first, the current working |
| 100 |
directory (".") and then in |
| 101 |
.IR /etc/sane.d . |
| 102 |
If the value of the |
| 103 |
environment variable ends with the directory separator character, then |
| 104 |
the default directories are searched after the explicitly specified |
| 105 |
directories. For example, setting |
| 106 |
.B SANE_CONFIG_DIR |
| 107 |
to "/tmp/config:" would result in directories |
| 108 |
.IR tmp/config , |
| 109 |
.IR . , |
| 110 |
and |
| 111 |
.I "/etc/sane.d" |
| 112 |
being searched (in this order). |
| 113 |
.TP |
| 114 |
.B SANE_DEBUG_MA1509 |
| 115 |
If the library was compiled with debug support enabled, this |
| 116 |
environment variable controls the debug level for this backend. Higher |
| 117 |
debug levels increase the verbosity of the output. |
| 118 |
|
| 119 |
.SH "SEE ALSO" |
| 120 |
.BR sane (7), |
| 121 |
.BR sane\-usb (5), |
| 122 |
.BR sane\-gt68xx (5), |
| 123 |
.BR sane\-plustek (5), |
| 124 |
.BR sane\-mustek_usb (5), |
| 125 |
.BR sane\-mustek (5), |
| 126 |
.BR sane\-mustek_pp (5), |
| 127 |
.br |
| 128 |
.I http://www.meier\-geinitz.de/sane/ma1509\-backend/ |
| 129 |
|
| 130 |
.SH AUTHOR |
| 131 |
Henning Meier-Geinitz |
| 132 |
.RI < henning@meier\-geinitz.de > |
| 133 |
|
| 134 |
.SH BUGS |
| 135 |
Resolutions higher than 600 dpi don't work |
| 136 |
.br |
| 137 |
Transparency adapter and automatic document feeder is not supported yet |
| 138 |
.br |
| 139 |
No support for "high-speed" mode (jpeg) |
| 140 |
.PP |
| 141 |
More detailed bug information is available at the MA-1509 backend homepage |
| 142 |
.IR http://www.meier\-geinitz.de/sane/ma1509-backend/ . |