| 1 |
.TH sane\-coolscan 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-coolscan |
| 3 |
|
| 4 |
.SH NAME |
| 5 |
sane\-coolscan \- SANE backend for Nikon film-scanners |
| 6 |
|
| 7 |
.SH ABOUT THIS FILE |
| 8 |
|
| 9 |
This file is a short description of the coolscan backend for |
| 10 |
.BR SANE . |
| 11 |
|
| 12 |
.SH DESCRIPTION |
| 13 |
|
| 14 |
The |
| 15 |
.B sane\-coolscan |
| 16 |
library implements a SANE backend that provides the interface to the following Nikon |
| 17 |
Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000. |
| 18 |
|
| 19 |
.B Even though the backend has worked for a number of people, there are still some |
| 20 |
problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o) |
| 21 |
and the autofocus command. |
| 22 |
You should consider this backend 'alpha' and be careful when using it the first time. |
| 23 |
|
| 24 |
.SH CONFIGURATION |
| 25 |
|
| 26 |
The configuration file for this backend resides in |
| 27 |
.IR /etc/sane.d/coolscan.conf . |
| 28 |
|
| 29 |
Its content is a list of device names that correspond to Nikon Coolscan scanners. Empty lines |
| 30 |
and lines starting with a hash mark (#) are ignored. A sample configuration file is |
| 31 |
shown below: |
| 32 |
|
| 33 |
.nf |
| 34 |
#scsi Vendor Model Type |
| 35 |
scsi Nikon * Scanner |
| 36 |
/dev/scanner |
| 37 |
.fi |
| 38 |
|
| 39 |
The special device name must be a generic SCSI device or a symlink to such a device. |
| 40 |
To find out to which device your scanner is assigned and how you can set the |
| 41 |
permissions of that device, have a look at |
| 42 |
.BR sane\-scsi (5). |
| 43 |
|
| 44 |
.SH SCSI ADAPTER TIPS |
| 45 |
|
| 46 |
Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the |
| 47 |
Coolscan scanners. These systems hang when the autofocus command is send to the Scanner. |
| 48 |
To see a list of which card/driver combinations work or don't work have a look at: |
| 49 |
.I http://andreas.rick.free.fr/sane/autofocus.html. |
| 50 |
|
| 51 |
.SH FILES |
| 52 |
.TP |
| 53 |
The backend configuration file: |
| 54 |
.I /etc/sane.d/coolscan.conf |
| 55 |
.TP |
| 56 |
The static library implementing this backend: |
| 57 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan.a |
| 58 |
.TP |
| 59 |
The shared library implementing this backend: |
| 60 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan.so |
| 61 |
(present on systems that support dynamic loading) |
| 62 |
|
| 63 |
.SH ENVIRONMENT |
| 64 |
|
| 65 |
.TP |
| 66 |
.B SANE_DEBUG_COOLSCAN |
| 67 |
If the library was compiled with debug support enabled, this environment |
| 68 |
variable controls the debug level for this backend. E.g., a value of 128 |
| 69 |
requests all debug output to be printed. Smaller levels reduce verbosity. |
| 70 |
|
| 71 |
Examples: |
| 72 |
|
| 73 |
On bash: |
| 74 |
.br |
| 75 |
export SANE_DEBUG_COOLSCAN=8 |
| 76 |
|
| 77 |
On csh: |
| 78 |
.br |
| 79 |
setenv SANE_DEBUG_COOLSCAN 8 |
| 80 |
|
| 81 |
.SH BUGS |
| 82 |
|
| 83 |
The autofocus command does not work with some SCSI card/driver combinations. |
| 84 |
.PP |
| 85 |
The gamma table is not implemented for the LS1000 yet. |
| 86 |
.PP |
| 87 |
The dust-removal is not working yet. |
| 88 |
|
| 89 |
.SH SEE ALSO |
| 90 |
.BR sane (7), |
| 91 |
.BR sane\-scsi (5) |
| 92 |
|
| 93 |
.TP |
| 94 |
.I http://andreas.rick.free.fr/sane/ |
| 95 |
The homepage of this backend. |
| 96 |
.TP |
| 97 |
.I http://www.sema.be/coolscan/ |
| 98 |
The original version of the coolscan backend by Didier. |
| 99 |
|
| 100 |
.SH THANKS TO |
| 101 |
Didier Carlier \- For writing the original Coolscan backend (without it I would not have started this). |
| 102 |
.PP |
| 103 |
Oliver Rauch \- For adapting xsane so quickly to the infrared stuff. |
| 104 |
.PP |
| 105 |
All the other people working on SANE. |
| 106 |
|
| 107 |
.SH AUTHOR |
| 108 |
Andreas Rick |
| 109 |
|
| 110 |
.SH EMAIL-CONTACT |
| 111 |
.I [email protected] |