1 .TH sane\-coolscan 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-coolscan
3
4 .SH NAME
5 sane\-coolscan \- SANE backend for Nikon film-scanners
6
7 .SH ABOUT THIS FILE
8
9 This file is a short description of the coolscan backend for
10 .BR SANE .
11
12 .SH DESCRIPTION
13
14 The
15 .B sane\-coolscan
16 library implements a SANE backend that provides the interface to the following Nikon
17 Coolscan Film scanners: Nikon LS20, LS30, LS1000, LS2000.
18
19 .B Even though the backend has worked for a number of people, there are still some
20 problems, especially in combination with some SCSI card/drivers (AHA-1505/aha152x.o)
21 and the autofocus command.
22 You should consider this backend 'alpha' and be careful when using it the first time.
23
24 .SH CONFIGURATION
25
26 The configuration file for this backend resides in
27 .IR /etc/sane.d/coolscan.conf .
28
29 Its content is a list of device names that correspond to Nikon Coolscan scanners. Empty lines
30 and lines starting with a hash mark (#) are ignored. A sample configuration file is
31 shown below:
32
33 .nf
34 #scsi Vendor Model Type
35 scsi Nikon * Scanner
36 /dev/scanner
37 .fi
38
39 The special device name must be a generic SCSI device or a symlink to such a device.
40 To find out to which device your scanner is assigned and how you can set the
41 permissions of that device, have a look at
42 .BR sane\-scsi (5).
43
44 .SH SCSI ADAPTER TIPS
45
46 Some SCSI-adapters and low-level SCSI drivers do not work correctly with this backend and the
47 Coolscan scanners. These systems hang when the autofocus command is send to the Scanner.
48 To see a list of which card/driver combinations work or don't work have a look at:
49 .I http://andreas.rick.free.fr/sane/autofocus.html.
50
51 .SH FILES
52 .TP
53 The backend configuration file:
54 .I /etc/sane.d/coolscan.conf
55 .TP
56 The static library implementing this backend:
57 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan.a
58 .TP
59 The shared library implementing this backend:
60 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan.so
61 (present on systems that support dynamic loading)
62
63 .SH ENVIRONMENT
64
65 .TP
66 .B SANE_DEBUG_COOLSCAN
67 If the library was compiled with debug support enabled, this environment
68 variable controls the debug level for this backend. E.g., a value of 128
69 requests all debug output to be printed. Smaller levels reduce verbosity.
70
71 Examples:
72
73 On bash:
74 .br
75 export SANE_DEBUG_COOLSCAN=8
76
77 On csh:
78 .br
79 setenv SANE_DEBUG_COOLSCAN 8
80
81 .SH BUGS
82
83 The autofocus command does not work with some SCSI card/driver combinations.
84 .PP
85 The gamma table is not implemented for the LS1000 yet.
86 .PP
87 The dust-removal is not working yet.
88
89 .SH SEE ALSO
90 .BR sane (7),
91 .BR sane\-scsi (5)
92
93 .TP
94 .I http://andreas.rick.free.fr/sane/
95 The homepage of this backend.
96 .TP
97 .I http://www.sema.be/coolscan/
98 The original version of the coolscan backend by Didier.
99
100 .SH THANKS TO
101 Didier Carlier \- For writing the original Coolscan backend (without it I would not have started this).
102 .PP
103 Oliver Rauch \- For adapting xsane so quickly to the infrared stuff.
104 .PP
105 All the other people working on SANE.