Debian Codegraph @

upstream/debian-unstable/man5/sane-rts8891.5

raw
1 .TH "sane\-rts8891" "5" "8 Dec 2008" "" "SANE Scanner Access Now Easy"
2 .SH "NAME"
3 sane\-rts8891 \- SANE backend for rts8891 based scanners
4 .SH "DESCRIPTION"
5 The
6 .B sane\-rts8891
7 library implements a SANE (Scanner Access Now Easy) backend that
8 provides access to scanners based on the rts8891 ASIC.
9 .PP
10 The scanners that work with this backend are:
11 .PP
12 .RS
13 .ft CR
14 .nf
15 Vendor Model status
16 \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-
17 Umax Astra 4400 untested
18 Umax Astra 4450 untested
19 HP scanjet 4000c good
20 HP scanjet 4470c good
21 .fi
22 .ft R
23 .RE
24
25 The options the backend supports can either be selected through
26 command line options to programs like
27 .BR scanimage (1)
28 or through GUI elements in
29 .BR xscanimage (1)
30 or
31 .BR xsane (1).
32
33 .br
34 If you notice any strange behavior, please report to the backend
35 maintainer or to the SANE mailing list.
36
37 Valid command line options and their syntax can be listed by using
38
39 .RS
40 scanimage \-\-help \-d rts8891
41 .RE
42
43 .TP
44 .B Scan Mode Options
45
46 .TP
47 .B \-\-mode
48 selects the basic mode of operation of the scanner. Valid choices are
49 .IR "Color" ,
50 .I Gray
51 and
52 .IR Lineart .
53 The default mode is
54 .IR Color .
55 The
56 .I Lineart
57 mode is for black and white only (1 bit).
58 .I Gray
59 will produce 256 levels of gray (8 bits).
60 .I Color
61 mode allows for over 16 million different colors produced from
62 24 bits of color information.
63
64 .TP
65 .B \-\-resolution
66 selects the resolution for a scan. The horizontal and vertical resolutions are set
67 by the value of this option. The scanner is capable of the following resolutions for the specified option value:
68 .PP
69 .RS
70 .ft CR
71 .nf
72 Value Hor. Resolution Vert. Resolution
73 \-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
74 75 75dpi 75dpi
75 150 150dpi 150dpi
76 300 300dpi 300dpi
77 600 600dpi 600dpi
78 1200 1200dpi 1200dpi
79 .fi
80 .ft R
81 .RE
82
83 .TP
84 .B \-\-preview
85 requests a preview scan. The resolution used for that scan is 75 dpi
86 and the scan area and the scan mode are as specified through their options,
87 or the default if not specified. The default value for preview mode is "no".
88
89 .TP
90 .B \-\-threshold
91 selects the minimum\-brightness to get a white point. The threshold is only used with Lineart mode scans.
92 It is specified as a percentage in the range 0..100% (in steps of 1).
93 The default value of the threshold option is 50.
94
95
96 .SH "CONFIGURATION FILE"
97 The configuration file
98 .I /etc/sane.d/rts8891.conf
99 contains the usb device ids of supported scanners (eg usb 0x043d 0x007c) and scanner configuration options.
100 Empty lines and lines starting with a hash mark (#) are
101 ignored.
102 .PP
103 The options supported are
104 .BR allowsharing ,
105 .B modelnumber
106 .
107
108 Option
109 .TP
110 .B allowsharing
111 enables or not the sharing of the scanner between multiple frontends at the same time.
112 .TP
113 .B modelnumber
114 is used to force the reported model by the backend and is only useful in the case of a scanner which NVRAM has been erased.
115
116 .RS
117 .ft CR
118 .nf
119 0 to report a HP4470c.
120 1 to report a HP4400c.
121 2 to report an Astra 4400.
122 .fi
123 .ft R
124 .RE
125
126 .SH "FILES"
127 .TP
128 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-rts8891.a
129 The static library implementing this backend.
130 .TP
131 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-rts8891.so
132 The shared library implementing this backend (present on systems that
133 support dynamic loading).
134
135 .SH "ENVIRONMENT"
136 .TP
137 .B SANE_DEBUG_RTS8891 SANE_DEBUG_RTS8891_LOW SANE_DEBUG_RTS88XX_LIB
138 If the library was compiled with debug support enabled, these
139 environment variables control the debug level for this backend. E.g.,
140 a value of 255 requests all debug output to be printed. Smaller levels
141 reduce verbosity.
142
143 .SH "LIMITATIONS"
144 Scanners of the same model exist with different sensors, due to lack of data
145 (ie USB logs) some sensors are better supported than others. At least 75 dpi
146 mode is working for any model. Sharing the scanner between several frontends
147 at the same time (allowsharing option) may not work on some USB controllers.
148 .PP
149 XPA is not (yet) supported.
150 .SH "BUGS"
151 .br
152 No bugs currently known.
153
154 .SH "SEE ALSO"
155 .BR sane\-scsi (5),
156 .BR scanimage (1),
157 .BR xscanimage (1),
158 .BR xsane (1),
159 .BR sane (7)
160
161 .SH "AUTHOR"
162 .TP
163 This backend has been developed by St\['e]phane Voltz.
164 .I http://stef.dev.free.fr/sane/rts8891
165
166 .SH "CREDITS"
167 .TP
168 Many thanks go to:
169 Laurent Fournier who donated me a HP4470c.
170 Vladimir Sysoev and "TheUnruly Squash" for the time they spent recording
171 USB activity and testing the experimental version on HP4400 models.