Debian Codegraph @

upstream/debian-unstable/man5/sane-plustek_pp.5

raw
1 .TH sane\-plustek_pp 5 "14 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-plustek_pp
3 .SH NAME
4 sane\-plustek_pp \- SANE backend for Plustek parallel port
5 flatbed scanners
6 .SH DESCRIPTION
7 The
8 .B sane\-plustek_pp
9 library implements a SANE (Scanner Access Now Easy) backend that
10 provides access to Plustek ASIC 9600[1/3] and P9800[1/3] based
11 parallel port flatbed scanners.
12
13 .SH "SUPPORTED DEVICES"
14
15 At present, the following scanners should work with this backend:
16 .PP
17 .B "PLUSTEK SCANNERS"
18 .PP
19 .ft CR
20 .nf
21 Parallelport Model: ASIC: Properties:
22 ---------------------- ----- ------------------------
23 OpticPro PT12 98003 600x1200 dpi 36bit 512Kb
24 OpticPro P12 98003 600x1200 dpi 36bit 512Kb
25 OpticPro 9636T/12000T 98001 600x1200 dpi 36bit 512Kb
26 OpticPro 12000P Turbo 98001 600x1200 dpi 36bit 512Kb
27 OpticPro 9636P+/Turbo 98001 600x1200 dpi 36bit 512Kb
28 OpticPro 9636P 96003 600x1200 dpi 36bit 128Kb
29 OpticPro 12000P/96000P 96003 600x1200 dpi 36bit 128Kb
30 OpticPro 1236P 96003 600x1200 dpi 30bit 128Kb
31 OpticPro 9600P 96003 600x1200 dpi 30bit 128Kb
32 OpticPro 9630P/FBIV 96003 600x1200 dpi 30bit 128Kb
33 OpticPro 9630PL (14") 96003 600x1200 dpi 30bit 128Kb
34 OpticPro A3I 96003 400x800 dpi 36bit 128Kb
35 OpticPro 600P/6000P 96003 300x600 dpi 30bit 32Kb
36 OpticPro 4831P 96003 300x600 dpi 30bit 32Kb
37 OpticPro 4830P/FBIII 96003 300x600 dpi 30bit 32Kb
38 OpticPro 4800P/FBII 96001 300x600 dpi 24bit 32Kb
39 .fi
40 .ft R
41 .PP
42
43 .B "PRIMAX SCANNERS"
44
45 There are some scanners sold by Primax, but they are in fact
46 Plustek devices. These scanners are also supported.
47 The following table will show the relationship:
48 .PP
49 .ft CR
50 .nf
51 Model: Plustek Model: Remarks:
52 --------------------------- -------------- ------------
53 Colorado 4800 OpticPro 4800 not tested
54 Compact 4800 Direct OpticPro 600 mov=2
55 Compact 4800 Direct 30bit OpticPro 4830 mov=7
56 Compact 9600 Direct 30bit OpticPro 9630 works
57 .fi
58 .ft R
59 .PP
60
61 .B "GENIUS SCANNERS"
62
63 The following devices are sold as Genius Scanners, but are in fact
64 Plustek devices.
65 The table will show the relationship:
66 .PP
67 .ft CR
68 .nf
69 Model: Remarks:
70 --------------------------- ----------------------------
71 Colorpage Vivid III V2 Like P12 but has two buttons
72 and Wolfson DAC
73 .fi
74 .ft R
75 .PP
76
77 .B "ARIES SCANNERS"
78
79 There's one scanner sold as Aries Scanner, but is in fact a
80 Plustek device.
81 The following table will show the relationship:
82 .PP
83 .ft CR
84 .nf
85 Model: Plustek Model: Remarks:
86 --------------------------- -------------- ------------
87 Scan-It 4800 OpticPro 600 mov=2
88 .fi
89 .ft R
90 .PP
91
92 .B "BrightScan SCANNERS"
93
94 There's one scanner sold as BrightScan OpticPro Scanner, this is also
95 a rebadged Plustek device.
96 The following table will show the relationship:
97 .PP
98 .ft CR
99 .nf
100 Model: Remarks:
101 --------------------------- ----------------------------
102 BrightScan OpticPro OpticPro P12
103 .fi
104 .ft R
105
106 .SH "DEVICE NAMES"
107 This backend's default device is:
108 .PP
109 .RS
110 .I 0x378
111 .RE
112 .PP
113 This "default device" will be used if no configuration
114 file can be found. It is the base address of the parallel port
115 on i386 machines.
116 .PP
117 As the backend supports up to four devices, it is possible to
118 specify them in the configuration file
119 .PP
120 .RS
121 .I /etc/sane.d/plustek_pp.conf
122 .RE
123 .PP
124 See this file for examples.
125 .PP
126
127 .SH "CONFIGURATION"
128 .PP
129 This section describes the backend's configuration file entries.
130 The file is located at:
131 .I /etc/sane.d/plustek_pp.conf
132 .PP
133 For a proper setup, you will need at least two entries:
134 .RS
135 .PP
136 .I [direct]
137 .br
138 .I device 0x378
139 .RE
140 .PP
141 .I direct
142 tells the backend, that the following devicename (here
143 .IR 0x378 )
144 has to be interpreted as parallel port scanner device. In
145 fact it is the address to use. Alternatively you can use
146 .I /dev/parport0
147 if the backend has been compiled with libieee1284 support.
148 .PP
149 Further options:
150 .PP
151 option warmup t
152 .RS
153 .I t
154 specifies the warmup period in seconds
155 .RE
156 .PP
157 option lampOff t
158 .RS
159 .I t
160 is the time in seconds for switching off the lamps in
161 standby mode
162 .RE
163 .PP
164 option lOffonEnd b
165 .RS
166 .I b
167 specifies the behaviour when closing the backend, 1 --> switch
168 lamps off, 0 --> do not change lamp status
169 .RE
170 .PP
171 option mov m
172 .RS
173 .I m
174 is the model override switch, which only works in direct mode.
175 .TP
176 .IR m " = 0"
177 default: no override
178 .TP
179 .IR m " = 1"
180 OpticPro 9630PL override (works if OP9630
181 has been detected) forces legal size (14")
182 .TP
183 .IR m " = 2"
184 Primax 4800Direct override (works if OP600
185 has been detected) swaps red/green color
186 .TP
187 .IR m " = 3"
188 OpticPro 9636 override (works if OP9636 has
189 been detected) disables backends
190 transparency/negative capabilities
191 .TP
192 .IR m " = 4"
193 OpticPro 9636P override (works if OP9636 has
194 been detected) disables backends
195 transparency/negative capabilities
196 .TP
197 .IR m " = 5"
198 OpticPro A3I override (works if OP12000 has
199 been detected) enables A3 scanning
200 .TP
201 .IR m " = 6"
202 OpticPro 4800P override (works if OP600
203 has been detected) swaps red/green color
204 .TP
205 .IR m " = 7"
206 Primax 4800Direct 30bit override (works if
207 OP4830 has been detected)
208 .RE
209 .PP
210 See the
211 .I plustek_pp.conf
212 file for examples.
213 .PP
214
215 .SH "PARALLEL PORT MODES"
216 .PP
217 The current driver works best, when the parallel port
218 has been set to EPP-mode. When detecting any other
219 mode such as ECP or PS/2 the driver tries to set to a
220 faster, supported mode. If this fails, it will use the
221 SPP mode, as this mode should work with all Linux supported
222 parallel ports. If in doubt, enter your BIOS and set it to
223 any mode except ECP.
224 .PP
225 Former Plustek scanner models (4830, 9630) supplied a
226 ISA parallel port adapter card. This card is
227 .BR not
228 supported by the driver.
229 .PP
230 The ASIC 96001/3 based models have sometimes trouble with
231 high resolution modes. If you encounter sporadic corrupted
232 images (parts duplicated or shifted horizontally) kill all
233 other applications before scanning and (if sufficient
234 memory available) disable swapping.
235 .PP
236 See the
237 .I plustek_pp.conf
238 file for examples.
239 .PP
240
241 .SH FILES
242 .TP
243 .I /etc/sane.d/plustek_pp.conf
244 The backend configuration file
245 .TP
246 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-plustek_pp.a
247 The static library implementing this backend.
248 .TP
249 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-plustek_pp.so
250 The shared library implementing this backend (present on systems that
251 support dynamic loading).
252
253 .SH ENVIRONMENT
254 .TP
255 .B SANE_CONFIG_DIR
256 This environment variable specifies the list of directories that may
257 contain the configuration file. On *NIX systems, the directories are
258 separated by a colon (`:'), under OS/2, they are separated by a
259 semi-colon (`;'). If this variable is not set, the configuration file
260 is searched in two default directories: first, the current working
261 directory (".") and then in
262 .IR /etc/sane.d .
263 If the value of the
264 environment variable ends with the directory separator character, then
265 the default directories are searched after the explicitly specified
266 directories. For example, setting
267 .B SANE_CONFIG_DIR
268 to "/tmp/config:" would result in directories
269 .IR "tmp/config" ,
270 .IR "." ,
271 and
272 .I "/etc/sane.d"
273 being searched (in this order).
274 .TP
275 .B SANE_DEBUG_PLUSTEK_PP
276 If the library was compiled with debug support enabled, this
277 environment variable controls the debug level for this backend. Higher
278 debug levels increase the verbosity of the output.
279
280 Example:
281 export SANE_DEBUG_PLUSTEK_PP=10
282
283 .SH "SEE ALSO"
284 .BR sane (7),
285 .BR xscanimage (1),
286 .br
287 .I /usr/share/doc/libsane/plustek/Plustek\-PARPORT.changes
288
289 .SH "CONTACT AND BUG-REPORTS"
290 Please send any information and bug-reports to:
291 .br
292 .B SANE Mailing List
293 .PP
294 Additional info and hints can be obtained from our mailing-List archive at:
295 .IR http://www.sane\-project.org/mailing\-lists.html .
296 .PP
297 To obtain debug messages from the backend, please set the
298 environment-variable
299 .B SANE_DEBUG_PLUSTEK_PP
300 before calling your favorite SANE frontend (e.g.
301 .BR xscanimage (1)):
302 .PP
303 .I export SANE_DEBUG_PLUSTEK_PP=20 ; xscanimage
304 .PP
305 The value controls the verbosity of the output.
306 .PP
307
308 .SH "KNOWN BUGS & RESTRICTIONS"
309 .PP
310 * The Halftoning works, but the quality is poor
311 .PP
312 * Printers (especially HP models) will start to
313 print during scanning. This in fact is a problem
314 to other printers too, using bidirectional protocol
315 (see www.plustek.com (TAIWAN) page for further details)
316 .PP
317 * The driver does not support these manic scalings up
318 to 16 times the physical resolution. The only scaling
319 is done on resolutions between the physical resolution
320 of the CCD-sensor and the stepper motor i.e. you have a
321 600x1200 dpi scanner and you are scanning using 800dpi,
322 so scaling is necessary, because the sensor only delivers
323 600dpi but the motor is capable to perform 800dpi steps.
324 .PP
325 * On some devices, the pictures seems bluish
326 .PP
327 .I ASIC 98001 based models:
328 .PP
329 * The 300dpi transparency and negative mode does not work
330 correctly.
331 .PP
332 * There is currently no way to distinguish a model with
333 and without transparency unit.
334 .PP
335 * The scanned images seem to be too dark (P9636T)
336 .PP
337 .I ASIC 96003/1 based models:
338 .PP
339 * 30bit mode is currently not supported.
340 .PP
341 * On low end systems under heavy system load the
342 driver may lose data, which can result in picture
343 corruption or cause the sensor to hit the scan bed.
344 .PP