1 .TH sane\-hp3900 5 "06 Jan 2009" "" "SANE Scanner Access Now Easy"
2 .IX sane\-hp3900
3 .SH NAME
4 sane\-hp3900 \- SANE backend for RTS8822 chipset based scanners
5 .SH DESCRIPTION
6 The
7 .B sane\-hp3900
8 library implements a SANE (Scanner Access Now Easy) backend that provides
9 access at least to the following USB flatbed scanners:
10 .PP
11 .RS
12 .ft CR
13 .nf
14 Model: Chipset:
15 ------ --------
16 HP ScanJet 3800 RTS8822BL-03A
17 HP ScanJet 3970 RTS8822L-01H
18 HP ScanJet 4070 Photosmart RTS8822L-01H
19 HP ScanJet 4370 RTS8822L-02A
20 HP ScanJet G2710 RTS8822BL-03A
21 HP ScanJet G3010 RTS8822L-02A
22 HP ScanJet G3110 RTS8822L-02A
23 UMAX Astra 4900/4950 RTS8822L-01H *
24 BenQ 5550 RTS8823L-01E *
25 .fi
26 .ft R
27 .RE
28 .PP
29 More details can be found on the
30 .BR sane\-hp3900 (5)
31 backend homepage
32 .IR http://sourceforge.net/projects/hp3900\-series/ .
33 .PP
34 This is ALPHA software. Keep your hand at the scanner's plug and unplug it, if
35 scanner does not start to scan. See also the
36 .B BUGS
37 section.
38 .PP
39 If you own a scanner other than the ones listed above that works with this
40 backend, please let us know this by sending the scanner's exact model name and
41 the USB vendor and device ids (e.g. from
42 .IR /proc/bus/usb/devices ,
43 .BR sane\-find\-scanner (1)
44 or syslog) to us. Even if the scanner's name is only slightly different from
45 the models mentioned above, please let us know.
46 .PP
47
48 .SH CONFIGURATION
49 The contents of the
50 .I hp3900.conf
51 file is a list of usb lines containing vendor and product ids that correspond
52 to USB scanners. The file can also contain the names of device files that
53 correspond to an HP 39XX scanner. Empty lines and lines starting with a hash
54 mark (#) are ignored. The scanners are autodetected by
55 .B usb vendor_id product_id
56 statements which are already included into
57 .IR hp3900.conf .
58 "vendor_id" and "product_id" are hexadecimal numbers that identify the
59 scanner. If autodetection does not work, add the device name of your scanner
60 to the configuration file,
61 .PP
62
63 .SH FILES
64 .TP
65 .I /etc/sane.d/hp3900.conf
66 The backend configuration file (see also description of
67 .B SANE_CONFIG_DIR
68 below).
69 .TP
70 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-hp3900.a
71 The static library implementing this backend.
72 .TP
73 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-hp3900.so
74 The shared library implementing this backend (present on systems that
75 support dynamic loading).
76 .SH ENVIRONMENT
77 .TP
78 .B SANE_CONFIG_DIR
79 This environment variable specifies the list of directories that may
80 contain the configuration file. On *NIX systems, the directories are
81 separated by a colon (`:'), under OS/2, they are separated by a
82 semi-colon (`;'). If this variable is not set, the configuration file
83 is searched in two default directories: first, the current working
84 directory
85 .RI ( "." )
86 and then in
87 .IR /etc/sane.d .
88 If the value of the
89 environment variable ends with the directory separator character, then
90 the default directories are searched after the explicitly specified
91 directories. For example, setting
92 .B SANE_CONFIG_DIR
93 to "/tmp/config:" would result in directories
94 .IR "tmp/config" ,
95 .IR "." ,
96 and
97 .I /etc/sane.d
98 being searched (in this order).
99 .TP
100 .B SANE_DEBUG_HP3900
101 If the library was compiled with debug support enabled, this
102 environment variable controls the debug level for this backend. Higher
103 debug levels increase the verbosity of the output.
104
105 Example:
106 export SANE_DEBUG_HP3900=4
107
108 .SH "SEE ALSO"
109 .BR sane (7),
110 .BR sane\-usb (5),
111 .BR sane\-find\-scanner (1),
112 .br
113 .I http://sourceforge.net/projects/hp3900\-series/
114 .br
115 .I http://jkdsoftware.dyndns.org/drupal/?q=es/books/151
116
117 .SH AUTHOR
118 Jonathan Bravo Lopez
119 .RI < [email protected] >
120
121 .SH BUGS