.TH "sane\-genesys" "5" "4 Jul 2012" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-genesys |
| 3 |
.SH "NAME" |
| 4 |
sane\-genesys \- SANE backend for GL646, GL841, GL843, GL847 and GL124 based USB flatbed scanners |
| 5 |
.SH "DESCRIPTION" |
| 6 |
The |
| 7 |
.B sane\-genesys |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that provides |
| 9 |
access to USB flatbed scanners based on the Genesys GL646, GL841, GL843, GL847 and GL124 chips. |
| 10 |
At present, the following scanners are known to work with this backend: |
| 11 |
.PP |
| 12 |
.RS |
| 13 |
Canon LiDE 35/40/50/60/100/110/120/200/210/220/700 |
| 14 |
.br |
| 15 |
Hewlett-Packard HP2300C/HP2400/HP3670/HP3690/G4010/G4050 |
| 16 |
.br |
| 17 |
Medion MD5345/MD6228/MD6274 |
| 18 |
.br |
| 19 |
Panasonic KV-SS080 |
| 20 |
.br |
| 21 |
Plustek OpticBook 3600 |
| 22 |
.br |
| 23 |
Pentax DSmobile 600 |
| 24 |
.br |
| 25 |
Syscan/Ambir DocketPORT 467/485/487/665/685 |
| 26 |
.br |
| 27 |
Visioneer OneTouch 7100/Strobe XP100 (rev3)/XP200/XP300/Roadwarrior |
| 28 |
.br |
| 29 |
Xerox Travel Scanner 100, OneTouch 2400 |
| 30 |
.RE |
| 31 |
|
| 32 |
.PP |
| 33 |
This is stable software for supported models. But if you test new or untested scanners, keep |
| 34 |
your hand at the scanner's plug and unplug it, if the head bumps at the end of |
| 35 |
the scan area. |
| 36 |
.PP |
| 37 |
If you own a scanner other than the ones listed above that works with this |
| 38 |
backend, please let me know this by sending the scanner's exact model name and |
| 39 |
the USB vendor and device ids (e.g. from |
| 40 |
.IR /proc/bus/usb/devices , |
| 41 |
.I sane\-find\-scanner |
| 42 |
or syslog) to the sane\-devel mailing list. Even if the scanner's name is only |
| 43 |
slightly different from the models mentioned above, please let me know. |
| 44 |
.PP |
| 45 |
If you own a scanner that isn't detected by the genesys backend but has a GL646, |
| 46 |
GL841, GL843, GL847 or GL124 chipset, you can try to add it to the backend. |
| 47 |
.PP |
| 48 |
.SH "CALIBRATION" |
| 49 |
To give correct image quality, sheet fed scanners need to be calibrated using the |
| 50 |
calibration sheet sold with the scanner. To do calibration, you must insert this target |
| 51 |
in the feeder then start calibration either by passing the \-\-calibrate option to |
| 52 |
.BR scanimage (1) |
| 53 |
or by clicking on the available 'calibrate' button in the 'advanced options' in a graphical |
| 54 |
frontend. The result of the calibration is stored in a file in the home directory of the user doing it. |
| 55 |
If you plug the scanner in another machine or use it with another account, calibration |
| 56 |
will have to be redone, unless you use the \-\-calibration\-file option. |
| 57 |
If no home directory is defined, |
| 58 |
.B USERAPPPROFILE |
| 59 |
will be used, then |
| 60 |
.B TMPDIR |
| 61 |
or |
| 62 |
.BR TMP. |
| 63 |
If none of these directories exist, the backend will try |
| 64 |
to write in the current working directory. Flatbed scanners also make use of the calibration file as a cache |
| 65 |
to avoid calibration before each scan. Calibration file name is the name of the scanner model if only |
| 66 |
one scanner is detected. In the case of several identical model, the file name will be the name |
| 67 |
of the logical USB device name. The expiration time manages the time a calibration is valid in cache. |
| 68 |
A value of -1 means forever, 0 means no cache. |
| 69 |
|
| 70 |
.SH EXTRAS SCAN OPTIONS |
| 71 |
|
| 72 |
.TP |
| 73 |
.B \-\-lamp\-off\-time number |
| 74 |
The lamp will be turned off after the given time (in minutes). A value of 0 means that the lamp won't be turned off. |
| 75 |
|
| 76 |
.TP |
| 77 |
.B \-\-threshold percent |
| 78 |
0..100% (in steps of 1). Select minimum brightness to get a white point. Pixels |
| 79 |
with brightness below that value will be scanned as black. |
| 80 |
|
| 81 |
.TP |
| 82 |
.B \-\-brightness value |
| 83 |
\-100..100 (in steps of 1). Set the brightness enhancement. 0 for no enhancement, negative |
| 84 |
values to decrease brightness, and positive values to increase it. |
| 85 |
|
| 86 |
.TP |
| 87 |
.B \-\-contrast value |
| 88 |
\-100..100 (in steps of 1). Set the contrast enhancement. 0 for no enhancement, negative |
| 89 |
values to decrease contrast, and positive values to increase it. |
| 90 |
|
| 91 |
.TP |
| 92 |
.B \-\-disable-interpolation yes|no |
| 93 |
When using high resolutions where the horizontal resolution is smaller than vertical resolution, |
| 94 |
data is expanded by software to preserve picture geometry. This can be disabled by this option to get |
| 95 |
real scanned data. |
| 96 |
|
| 97 |
.TP |
| 98 |
.B \-\-disable-dynamic-lineart yes|no |
| 99 |
Disable use of a software adaptive algorithm to generate lineart and rely on hardware lineart. |
| 100 |
|
| 101 |
.TP |
| 102 |
.B \-\-color-filter None|Red|Green|Blue |
| 103 |
When using gray or lineart this option selects the used color. Using a color filter |
| 104 |
will give a monochrome scan. CIS based scanners can do true gray when no filter (None value) is |
| 105 |
selected. |
| 106 |
|
| 107 |
.TP |
| 108 |
.B \-\-lamp\-off\-scan |
| 109 |
The lamp will be turned off during the scan. Calibration is still done with lamp on. |
| 110 |
|
| 111 |
.TP |
| 112 |
.B \-\-clear\-calibration |
| 113 |
Clear calibration cache data, triggering a new calibration for the device when the |
| 114 |
next scan will happen. |
| 115 |
|
| 116 |
.TP |
| 117 |
.B \-\-calibration\-file |
| 118 |
Specify the calibration file name to use. At least the directory containing the file |
| 119 |
must exist, since it won't be created. This option is disabled if the backend is run |
| 120 |
as root. It maybe used in case of sheet-fed scanners to share a calibration file for several |
| 121 |
users. |
| 122 |
|
| 123 |
.TP |
| 124 |
.B \-\-expiration\-time |
| 125 |
Specify the time (in minutes) a cached calibration is considered valid. If older than the given value, a new |
| 126 |
calibration is done. A value of -1 means no expiration and cached value are kept forever unless cleared by |
| 127 |
user with the calibration clear option. A value of 0 means cache is disabled. |
| 128 |
|
| 129 |
.PP |
| 130 |
Additionally, several 'software' options are exposed by the backend. These |
| 131 |
are reimplementations of features provided natively by larger scanners, but |
| 132 |
running on the host computer. This enables smaller machines to have similar |
| 133 |
capabilities. Please note that these features are somewhat simplistic, and |
| 134 |
may not perform as well as the native implementations. Note also that these |
| 135 |
features all require that the driver cache the entire image in memory. This |
| 136 |
will almost certainly result in a reduction of scanning speed. |
| 137 |
|
| 138 |
.TP |
| 139 |
.B \-\-swcrop |
| 140 |
Requests the driver to detect the extremities of the paper within the larger |
| 141 |
image, and crop the empty edges. |
| 142 |
|
| 143 |
.TP |
| 144 |
.B \-\-swdeskew |
| 145 |
Requests the driver to detect the rotation of the paper within the larger |
| 146 |
image, and counter the rotation. |
| 147 |
|
| 148 |
.TP |
| 149 |
.B \-\-swdespeck \-\-despeck X |
| 150 |
Requests the driver to find and remove dots of X diameter or smaller from the |
| 151 |
image, and fill the space with the average surrounding color. |
| 152 |
|
| 153 |
.TP |
| 154 |
.B \-\-swskip 0..100% (in steps of 1) [0] |
| 155 |
Request driver to discard pages with low numbers of dark pixels. |
| 156 |
|
| 157 |
.TP |
| 158 |
.B \-\-swderotate[=(yes|no)] [no] |
| 159 |
Request driver to detect and correct 90 degree image rotation. |
| 160 |
|
| 161 |
.SH "SYSTEM ISSUES" |
| 162 |
This backend needs libusb-0.1.6 or later installed, and hasn't tested in other |
| 163 |
configuration than a linux kernel 2.6.9 or higher. However, it should work any |
| 164 |
system with libusb where the SANE package can be compiled. For |
| 165 |
setting permissions and general USB information look at |
| 166 |
.BR sane\-usb (5). |
| 167 |
|
| 168 |
|
| 169 |
.SH "CONFIGURATION" |
| 170 |
The contents of the |
| 171 |
.I genesys.conf |
| 172 |
file is a list of usb lines containing vendor and product ids that correspond |
| 173 |
to USB scanners. The file can also contain option lines. Empty lines and |
| 174 |
lines starting with a hash mark (#) are ignored. The scanners are |
| 175 |
autodetected by |
| 176 |
.B usb vendor_id product_id |
| 177 |
statements which are already included into |
| 178 |
.IR genesys.conf . |
| 179 |
"vendor_id" and "product_id" are hexadecimal numbers that identify the |
| 180 |
scanner. |
| 181 |
.PP |
| 182 |
|
| 183 |
.SH "FILES" |
| 184 |
.TP |
| 185 |
.I /etc/sane.d/genesys.conf |
| 186 |
The backend configuration file (see also description of |
| 187 |
.B SANE_CONFIG_DIR |
| 188 |
below). |
| 189 |
.TP |
| 190 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-genesys.a |
| 191 |
The static library implementing this backend. |
| 192 |
.TP |
| 193 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-genesys.so |
| 194 |
The shared library implementing this backend (present on systems that |
| 195 |
support dynamic loading). |
| 196 |
.SH "ENVIRONMENT" |
| 197 |
.TP |
| 198 |
.B SANE_CONFIG_DIR |
| 199 |
This environment variable specifies the list of directories that may |
| 200 |
contain the configuration file. On *NIX systems, the directories are |
| 201 |
separated by a colon (`:'), under OS/2, they are separated by a |
| 202 |
semi-colon (`;'). If this variable is not set, the configuration file |
| 203 |
is searched in two default directories: first, the current working |
| 204 |
directory (".") and then in |
| 205 |
.IR /etc/sane.d . |
| 206 |
If the value of the environment variable ends with the directory separator |
| 207 |
character, then the default directories are searched after the explicitly |
| 208 |
specified directories. For example, setting |
| 209 |
.B SANE_CONFIG_DIR |
| 210 |
to "/tmp/config:" would result in directories |
| 211 |
.IR tmp/config , |
| 212 |
.IR . , |
| 213 |
and |
| 214 |
.I "/etc/sane.d" |
| 215 |
being searched (in this order). |
| 216 |
.TP |
| 217 |
.B SANE_DEBUG_GENESYS |
| 218 |
If the library was compiled with debug support enabled, this environment |
| 219 |
variable controls the debug level for this backend. Higher debug levels |
| 220 |
increase the verbosity of the output. If the debug level is set to 1 or higher, |
| 221 |
some debug options become available that are normally hidden. Handle them with |
| 222 |
care. This will print messages related to core genesys functions. |
| 223 |
.TP |
| 224 |
.B SANE_DEBUG_GENESYS_IMAGE |
| 225 |
If the library was compiled with debug support enabled, this environment |
| 226 |
variable enables logging of intermediate image data. To enable this mode, |
| 227 |
set the environmental variable to 1. |
| 228 |
|
| 229 |
|
| 230 |
Example (full and highly verbose output for gl646): |
| 231 |
.br |
| 232 |
export SANE_DEBUG_GENESYS=255 |
| 233 |
|
| 234 |
.SH CREDITS |
| 235 |
|
| 236 |
Jack McGill for donating several sheetfed and flatbed scanners, which made possible to add support |
| 237 |
for them in the genesys backend: |
| 238 |
.RS |
| 239 |
Hewlett-Packard HP3670 |
| 240 |
.br |
| 241 |
Visioneer Strobe XP100 (rev3)/XP200/XP300/Roadwarrior |
| 242 |
.br |
| 243 |
Canon LiDE 200 |
| 244 |
.br |
| 245 |
Pentax DSmobile 600 |
| 246 |
.br |
| 247 |
Syscan/Ambir DocketPORT 467/485/487/665/685 |
| 248 |
.br |
| 249 |
Xerox Travel Scanner 100, Onetouch 2400 |
| 250 |
.RE |
| 251 |
.TP |
| 252 |
cncsolutions sponsored and supported the work on the Panasonic KV-SS080. |
| 253 |
.br |
| 254 |
.TP |
| 255 |
Brian Paavo from Benthic Science Limited for donating a Canoscan LiDE 700F. |
| 256 |
.br |
| 257 |
.TP |
| 258 |
Dany Qumsiyeh for donating a Canoscan LiDE 210 and a LiDE 220. |
| 259 |
.br |
| 260 |
.TP |
| 261 |
Luc Verhaegen for donating a Canoscan LiDE 120. |
| 262 |
.br |
| 263 |
|
| 264 |
.SH "SEE ALSO" |
| 265 |
.BR sane (7), |
| 266 |
.BR sane\-usb (5) |
| 267 |
.br |
| 268 |
|
| 269 |
|
| 270 |
.SH "AUTHOR" |
| 271 |
Oliver Rauch |
| 272 |
.br |
| 273 |
Henning Meier-Geinitz |
| 274 |
.RI < henning@meier\-geinitz.de > |
| 275 |
.br |
| 276 |
Gerhard Jaeger |
| 277 |
.RI < [email protected] > |
| 278 |
.br |
| 279 |
St\['e]phane Voltz |
| 280 |
.RI < [email protected] > |
| 281 |
.br |
| 282 |
Philipp Schmid |
| 283 |
.RI < [email protected] > |
| 284 |
.br |
| 285 |
Pierre Willenbrock |
| 286 |
.RI < [email protected] > |
| 287 |
.br |
| 288 |
Alexey Osipov |
| 289 |
.RI < [email protected] > |
| 290 |
for HP2400 final support |
| 291 |
|
| 292 |
.SH "LIMITATIONS" |
| 293 |
|
| 294 |
Powersaving isn't implemented for gl646 based scanner. Dynamic (emulated from gray data and with dithering) |
| 295 |
isn't enabled for gl646 scanners. Hardware lineart is limited up to 600 dpi for gl847 based scanners, |
| 296 |
due to the way image sensors are built. |
| 297 |
.PP |
| 298 |
This backend will be much slower if not using libusb\-1.0. So be sure that sane\-backends is built with |
| 299 |
the |
| 300 |
.B \-\-enable-libusb_1_0 |
| 301 |
option. |
| 302 |
|
| 303 |
.SH "BUGS" |
| 304 |
For the LiDE 200, the scanned data at 4800 dpi is obtained "as is" from sensor. |
| 305 |
It seems the windows driver does some digital processing to improve it, which is not implemented in the backend. |
| 306 |
.PP |