| 1 |
.TH sane\-sm3840 5 "11 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-sm3840 |
| 3 |
.SH NAME |
| 4 |
sane\-sm3840 \- SANE backend for Microtek scanners with SCAN08 USB chip |
| 5 |
.SH DESCRIPTION |
| 6 |
The |
| 7 |
.B sane\-sm3840 |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that |
| 9 |
provides access to some Microtek scanners with the SCAN08 |
| 10 |
USB chip. |
| 11 |
.PP |
| 12 |
There exist backends for Microtek scanners with SCSI command set. |
| 13 |
Refer to |
| 14 |
.BR sane\-microtek (5) |
| 15 |
and |
| 16 |
.BR sane\-microtek2 (5) |
| 17 |
for details. |
| 18 |
.PP |
| 19 |
There also exists a Microtek 3600 series driver, see |
| 20 |
.BR sane\-sm3600 (5) |
| 21 |
for details. |
| 22 |
.PP |
| 23 |
At present, the following |
| 24 |
scanners are known positively to work with this backend: |
| 25 |
.PP |
| 26 |
.RS |
| 27 |
.ft CR |
| 28 |
.nf |
| 29 |
Vendor Product ID: Remark: |
| 30 |
-------- -------------- ----------- |
| 31 |
Microtek ScanMaker 3840 All modes OK |
| 32 |
Microtek ScanMaker 4800 All modes OK |
| 33 |
.fi |
| 34 |
.ft R |
| 35 |
.RE |
| 36 |
.PP |
| 37 |
If you own a Microtek scanner with the SCAN08 chip other than the ones |
| 38 |
listed above, it may or may not work with SANE. Feel free to contact the |
| 39 |
backend author |
| 40 |
.RI ( [email protected] ) |
| 41 |
to report results with scanners not on the list. |
| 42 |
|
| 43 |
|
| 44 |
.SH "FRONTEND OPTIONS" |
| 45 |
.PP |
| 46 |
The following options are supported by the |
| 47 |
.BR sane\-sm3840 |
| 48 |
driver: |
| 49 |
.TP |
| 50 |
.B \-\-mode color|gray|lineart|halftone |
| 51 |
Color or grayscale mode. |
| 52 |
|
| 53 |
.TP |
| 54 |
.B \-\-resolution 150|300|600|1200 |
| 55 |
Pixels per inch for scans. |
| 56 |
|
| 57 |
.TP |
| 58 |
.B \-\-depth 8|16 |
| 59 |
Note that the least significant bits of 16bpp mode may be noise. |
| 60 |
|
| 61 |
.TP |
| 62 |
.B \-\-brightness 1..4096 |
| 63 |
Higher numbers increase brightness of returned image. |
| 64 |
|
| 65 |
.TP |
| 66 |
.B \-\-contrast 0.1..9.9 |
| 67 |
Larger numbers decrease contrast of returned image. |
| 68 |
|
| 69 |
.TP |
| 70 |
.B \-\-lamp\-timeout 1..15 |
| 71 |
Time in minutes until the lamp is turned off after a scan. |
| 72 |
|
| 73 |
.SH CONFIGURATION |
| 74 |
This backend does not support a configuration file right now. |
| 75 |
|
| 76 |
.SH FILES |
| 77 |
.TP |
| 78 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-sm3840.a |
| 79 |
The static library implementing this backend. |
| 80 |
.TP |
| 81 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-sm3840.so |
| 82 |
The shared library implementing this backend (present on systems that |
| 83 |
support dynamic loading). |
| 84 |
|
| 85 |
|
| 86 |
.SH ENVIRONMENT |
| 87 |
.TP |
| 88 |
.B SANE_DEBUG_SM3840 |
| 89 |
If the library was compiled with debug support enabled, this |
| 90 |
environment variable controls the debug level for this backend. E.g., |
| 91 |
a value of 128 requests all debug output to be printed. Smaller |
| 92 |
levels reduce verbosity. To see error messages on stderr set |
| 93 |
.B SANE_DEBUG_SM3840 |
| 94 |
to 1. |
| 95 |
|
| 96 |
.SH "SEE ALSO" |
| 97 |
.BR sane (7), |
| 98 |
.BR sane\-microtek (5), |
| 99 |
.BR sane\-microtek2 (5), |
| 100 |
.BR sane\-sm3600 (5) |
| 101 |
.br |
| 102 |
.I http://www.ziplabel.com/sm3840 |
| 103 |
|
| 104 |
.SH AUTHOR |
| 105 |
Earle F. Philhower III |
| 106 |
.RI < [email protected] > |