Debian Codegraph @

upstream/debian-unstable/man5/sane-teco3.5

raw
1 .TH sane\-teco3 5 "14 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-teco3
3 .SH NAME
4 sane\-teco3 \- SANE backend for TECO / RELISYS scanners
5 .SH DESCRIPTION
6 The
7 .B sane\-teco3
8 library implements a SANE (Scanner Access Now Easy) backend that
9 provides access to some TECO SCSI flatbed scanners. This backend
10 should be considered
11 .B alpha-quality
12 software! TECO scanners are sold under
13 various brands like RELYSIS, PIOTECH, TRUST. This backend may or
14 may not support yours.
15 .PP
16 The scanners that should work with this backend are:
17 .PP
18 .RS
19 .ft CR
20 .nf
21 Vendor Model TECO model status
22 --------------------------- ---------- ----------
23 Relisys Scorpio VM3552 tested
24 Plustek OpticPro 2400SP VM3552 untested
25 PIOTECH Splendeur 3024 VM3552 tested
26 Trust Imagery 2400 SP VM3552 tested
27 Trust Imagery 4800 SP+ VM3552 tested
28 Trust Imagery 9600 SP VM3552 untested
29 .fi
30 .ft R
31 .RE
32
33 The TECO VM number can usually be found at the back of the
34 scanner. It is also part of the FCC ID.
35
36 The options the backend supports can either be selected through
37 command line options to programs like
38 .BR scanimage (1)
39 or through GUI
40 elements in
41 .BR xscanimage (1)
42 or
43 .BR xsane (1).
44
45 .br
46 If you have any success with a scanner not listed here, or if you notice
47 any strange behavior, please report to the backend maintainer or to
48 the SANE mailing list.
49
50 .SH OPTIONS
51 Valid command line options and their syntax can be listed by using:
52
53 .RS
54 scanimage \-\-help \-d teco3
55 .RE
56
57 .TP
58 .B Scan Mode
59
60 .TP
61 .B \-\-mode Black & White|Grayscale|Color
62 Selects the basic mode of operation of the scanner.
63 The
64 .I Black & White
65 mode is black and white only (1 bit).
66 .I Grayscale
67 will produce 256 levels of gray (8 bits).
68 .I Color
69 will produce a 24-bit color image.
70
71 .TP
72 .B \-\-resolution 1..1200
73 Selects the resolution for a scan. The scanner can do all resolutions
74 between 1 and 1200, in increments of 1.
75
76 .TP
77 .B \-\-preview
78 Requests a preview scan. The resolution used for that scan is 22 dpi
79 and the scan area is the maximum allowed. The scan mode is user
80 selected. The default is "no".
81
82 .TP
83 .B Geometry options
84
85 .TP
86 .B \-l \-t \-x \-y
87 Control the scan area:
88 .B \-l
89 sets the top left x coordinate,
90 .B \-t
91 the top left y coordinate,
92 .B \-x
93 selects the width and
94 .B \-y
95 the height of the scan area.
96 All parameters are specified in millimeters by default.
97
98 .SH OPTIONS FOR COLOR MODE ONLY
99
100 .TP
101 .B \-\-custom\-gamma
102 Allows the user to specify a gamma table (see the
103 next 3 parameters).
104
105 .TP
106 .B \-\-red\-gamma\-table
107 Can be used to download a user defined
108 gamma table for the red channel. The table must be 1024 bytes long.
109
110 .TP
111 .B \-\-green\-gamma\-table
112 Can be used to download a user defined
113 gamma table for the green channel. The table must be 1024 bytes long.
114
115 .TP
116 .B \-\-blue\-gamma\-table
117 Can be used to download a user defined gamma table
118 for the blue channel. The table must be 1024 bytes long.
119
120
121 .SH CONFIGURATION FILE
122 The configuration file
123 .I /etc/sane.d/teco3.conf
124 supports only one item: the device name to use (eg
125 .IR /dev/scanner ).
126
127
128 .SH FILES
129 .TP
130 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-teco3.a
131 The static library implementing this backend.
132 .TP
133 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-teco3.so
134 The shared library implementing this backend (present on systems that
135 support dynamic loading).
136
137
138 .SH ENVIRONMENT
139 .TP
140 .B SANE_DEBUG_TECO3
141 If the library was compiled with debug support enabled, this
142 environment variable controls the debug level for this backend. E.g.,
143 a value of 128 requests all debug output to be printed. Smaller levels
144 reduce verbosity.
145
146
147 .SH LIMITATIONS
148 The windows TWAIN driver has many more options than this SANE
149 backend. However they are only software adjustments. This backend only
150 implements what the scanner can support.
151
152
153 .SH BUGS
154 Not much.
155
156
157 .SH "SEE ALSO"
158 .BR sane\-scsi (5),
159 .BR scanimage (1),
160 .BR xscanimage (1),
161 .BR xsane (1),
162 .BR sane (7)
163
164
165 .SH AUTHOR
166 .TP
167 The package is actively maintained by Frank Zago.
168 .I http://www.zago.net/sane/#teco3