| 1 |
.TH sane\-sceptre 5 "11 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-sceptre |
| 3 |
.SH NAME |
| 4 |
sane\-sceptre \- SANE backend for SCEPTRE scanners |
| 5 |
.SH DESCRIPTION |
| 6 |
The |
| 7 |
.B sane\-sceptre |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that |
| 9 |
provides access to Sceptre flatbed scanners. This backend should be |
| 10 |
considered |
| 11 |
.B beta-quality |
| 12 |
software! Please report any strange behavior to the maintainer of the |
| 13 |
backend or to the SANE mailing list. |
| 14 |
.PP |
| 15 |
At present, only one scanner is known to work with this backend: |
| 16 |
.PP |
| 17 |
.RS |
| 18 |
.ft CR |
| 19 |
.nf |
| 20 |
Model Connection Type |
| 21 |
--------------------------- ------------------- |
| 22 |
Sceptre VividScan S1200 SCSI |
| 23 |
.fi |
| 24 |
.ft R |
| 25 |
.RE |
| 26 |
|
| 27 |
The make of this scanner is KINPO, so other scanners from that manufacturer may also work (eg. the S600). |
| 28 |
.SH OPTIONS |
| 29 |
The options the backend supports can either be selected through command line |
| 30 |
options to programs like |
| 31 |
.BR scanimage (1) |
| 32 |
or through GUI elements in |
| 33 |
.BR xscanimage (1) |
| 34 |
or |
| 35 |
.BR xsane (1). |
| 36 |
|
| 37 |
Valid command line options and their syntax can be listed by using |
| 38 |
|
| 39 |
.RS |
| 40 |
scanimage \-\-help \-d sceptre |
| 41 |
.RE |
| 42 |
|
| 43 |
.TP |
| 44 |
.B Scan Mode |
| 45 |
|
| 46 |
.TP |
| 47 |
.B \-\-mode Lineart|Halftone|Gray|Color |
| 48 |
Selects the basic mode of operation of the scanner. |
| 49 |
The |
| 50 |
.I Lineart |
| 51 |
and |
| 52 |
.I Halftone |
| 53 |
mode are black and white only (1 bit). |
| 54 |
.I Gray |
| 55 |
will produce 256 levels of gray (8 bits). |
| 56 |
.I Color |
| 57 |
will produce a 24 bits |
| 58 |
color image. The scanner supports 30 bits internally but it only |
| 59 |
exports 24. |
| 60 |
|
| 61 |
.TP |
| 62 |
.B \-\-resolution 50..1200 |
| 63 |
Selects the resolution for a scan. The scanner can do several |
| 64 |
resolutions between 50 and 1200. |
| 65 |
|
| 66 |
.TP |
| 67 |
.B \-\-halftone\-pattern 1|2|3|4 |
| 68 |
Selects the pattern mode that is used in |
| 69 |
.I Halftone |
| 70 |
mode. |
| 71 |
|
| 72 |
.TP |
| 73 |
.B \-\-gamma\-correction Default|User Defined|High Density Printing|\ |
| 74 |
Low density printing|High contrast printing |
| 75 |
controls the scanner internal gamma correction. |
| 76 |
|
| 77 |
.TP |
| 78 |
.B \-\-custom\-gamma |
| 79 |
Allows the user to specify a gamma table (see the |
| 80 |
next 3 parameters). |
| 81 |
.I Color |
| 82 |
mode only. |
| 83 |
|
| 84 |
.TP |
| 85 |
.B \-\-red\-gamma\-table |
| 86 |
Can be used to download a user defined |
| 87 |
gamma table for the red channel. The table must be 256 bytes long. |
| 88 |
.I Color |
| 89 |
mode only. |
| 90 |
|
| 91 |
.TP |
| 92 |
.B \-\-green\-gamma\-table |
| 93 |
Can be used to download a user defined |
| 94 |
gamma table for the green channel. The table must be 256 bytes long. |
| 95 |
.I Color |
| 96 |
mode only. |
| 97 |
|
| 98 |
.TP |
| 99 |
.B \-\-blue\-gamma\-table |
| 100 |
Can be used to download a user defined gamma table |
| 101 |
for the blue channel. The table must be 256 bytes long. |
| 102 |
.I Color |
| 103 |
mode only. |
| 104 |
|
| 105 |
.TP |
| 106 |
.B \-\-threshold 0..255 |
| 107 |
Sets the threshold for black and white pixels in |
| 108 |
.I Lineart |
| 109 |
mode. Possible values are from 0 (darker) to 255 (lighter). |
| 110 |
|
| 111 |
.TP |
| 112 |
.B \-\-preview |
| 113 |
Requests a preview scan. The resolution used for that scan is 30 dpi |
| 114 |
and the scan area is the maximum allowed. The scan mode is user |
| 115 |
selected. The default is "no". |
| 116 |
|
| 117 |
.TP |
| 118 |
.B The geometry options |
| 119 |
|
| 120 |
.TP |
| 121 |
.B \-l \-t \-x \-y |
| 122 |
control the scan area: |
| 123 |
.B -l |
| 124 |
sets the top left x coordinate, |
| 125 |
.B \-t |
| 126 |
the top left y coordinate, |
| 127 |
.B \-x |
| 128 |
selects the width and |
| 129 |
.B \-y |
| 130 |
the height of the scan area. All parameters are specified in millimeters by default. |
| 131 |
|
| 132 |
|
| 133 |
.SH CONFIGURATION FILE |
| 134 |
The configuration file |
| 135 |
.I /etc/sane.d/sceptre.conf |
| 136 |
supports only one item: the device name to use |
| 137 |
.RI "(eg " /dev/scanner ). |
| 138 |
|
| 139 |
|
| 140 |
.SH FILES |
| 141 |
.TP |
| 142 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-sceptre.a |
| 143 |
The static library implementing this backend. |
| 144 |
.TP |
| 145 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-sceptre.so |
| 146 |
The shared library implementing this backend (present on systems that |
| 147 |
support dynamic loading). |
| 148 |
|
| 149 |
|
| 150 |
.SH ENVIRONMENT |
| 151 |
.TP |
| 152 |
.B SANE_DEBUG_SCEPTRE |
| 153 |
If the library was compiled with debug support enabled, this |
| 154 |
environment variable controls the debug level for this backend. E.g., |
| 155 |
a value of 128 requests all debug output to be printed. Smaller levels |
| 156 |
reduce verbosity. |
| 157 |
|
| 158 |
|
| 159 |
.SH LIMITATIONS |
| 160 |
.TP |
| 161 |
.B Resolutions |
| 162 |
The windows TWAIN driver can be set to any resolution between 50 to 1200 |
| 163 |
(excluding software interpolation). This backend cannot. Only a |
| 164 |
handful of resolution are available, although they should be numerous |
| 165 |
enough. |
| 166 |
|
| 167 |
|
| 168 |
.SH BUGS |
| 169 |
None known. |
| 170 |
|
| 171 |
|
| 172 |
.SH "SEE ALSO" |
| 173 |
.BR sane\-scsi (5), |
| 174 |
.BR scanimage (1), |
| 175 |
.BR xscanimage (1), |
| 176 |
.BR xsane (1), |
| 177 |
.BR sane (7) |
| 178 |
|
| 179 |
|
| 180 |
.SH AUTHOR |
| 181 |
|
| 182 |
.TP |
| 183 |
The package is actively maintained by Frank Zago. |
| 184 |
.I http://www.zago.net/sane/#sceptre |