1 .TH sane\-plustek 5 "03 Nov 2017" "" "SANE Scanner Access Now Easy"
2 .IX sane\-plustek
3 .SH NAME
4 sane\-plustek \- SANE backend for LM983[1/2/3] based
5 USB flatbed scanners
6 .SH DESCRIPTION
7 The
8 .B sane\-plustek
9 library implements a SANE (Scanner Access Now Easy) backend that
10 provides access to USB flatbed scanners based on National Semiconductor
11 Merlin chipsets (LM9831, 9832 and 9833).
12 If you're looking for parallel-port support for Plustek scanner
13 please refer to the
14 .BR sane\-plustek_pp (5)
15 backend.
16
17 .SH "SUPPORTED DEVICES"
18 The Backend is able to support USB scanner based on the National
19 Semiconductor chipsets LM9831, LM9832 and LM9833. The following tables
20 show various devices which are currently reported to work. If your
21 Plustek scanner has another Product ID, then the device is
22 .B NOT
23 supported by this backend.
24 .br
25
26 Vendor Plustek \- ID: 0x07B3
27 .br
28 .ft CR
29 .nf
30 ----------------------------------------------------------
31 USB Model: ASIC: Properties: Prod-ID
32 ----------------------------------------------------------
33 OpticPro U12 LM9831 600x1200dpi 42bit 512Kb 0x0010
34 OpticPro UT12 LM9831 600x1200dpi 42bit 512Kb 0x0013
35 OpticPro UT12 LM9832 600x1200dpi 42bit 512Kb 0x0017
36 OpticPro UT16 LM9832 600x1200dpi 42bit 512Kb 0x0017
37 OpticPro U24 LM9831 1200x2400dpi 42bit 2Mb 0x0011
38 OpticPro U24 LM9832 1200x2400dpi 42bit 2Mb 0x0015
39 OpticPro UT24 LM9832 1200x2400dpi 42bit 2Mb 0x0017
40 .fi
41 .ft R
42 .PP
43
44 Vendor KYE/Genius \- ID: 0x0458
45 .br
46 .ft CR
47 .nf
48 ----------------------------------------------------------
49 USB Model: ASIC: Properties: Prod-ID
50 ----------------------------------------------------------
51 Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2007
52 Colorpage HR6 V2 LM9832 600x1200dpi 42bit 512Kb 0x2008
53 Colorpage HR6A LM9832 600x1200dpi 42bit 512Kb 0x2009
54 Colorpage HR7 LM9832 600x1200dpi 42bit 512Kb 0x2013
55 Colorpage HR7LE LM9832 600x1200dpi 42bit 512Kb 0x2015
56 Colorpage HR6X LM9832 600x1200dpi 42bit 512Kb 0x2016
57 .fi
58 .ft R
59 .PP
60
61 Vendor Hewlett-Packard \- ID: 0x03F0
62 .br
63 .ft CR
64 .nf
65 ----------------------------------------------------------
66 USB Model: ASIC: Properties: Prod-ID
67 ----------------------------------------------------------
68 ScanJet 2100C LM9831 600x1200dpi 42bit 512Kb 0x0505
69 ScanJet 2200C LM9832 600x1200dpi 42bit 512Kb 0x0605
70 .fi
71 .ft R
72 .PP
73
74 Vendor Mustek \- ID: 0x0400
75 .br
76 .ft CR
77 .nf
78 ----------------------------------------------------------
79 USB Model: ASIC: Properties: Prod-ID
80 ----------------------------------------------------------
81 BearPaw 1200 LM9831 600x1200dpi 42bit 512Kb 0x1000
82 BearPaw 1200 LM9832 600x1200dpi 42bit 512Kb 0x1001*
83 BearPaw 2400 LM9832 1200x2400dpi 42bit 2Mb 0x1001
84 .fi
85 .ft R
86 * see also description for model override switch below!
87 .PP
88
89 Vendor UMAX \- ID: 0x1606
90 .br
91 .ft CR
92 .nf
93 ----------------------------------------------------------
94 USB Model: ASIC: Properties: Prod-ID
95 ----------------------------------------------------------
96 UMAX 3400 LM9832 600x1200dpi 42bit 512Kb 0x0050
97 UMAX 3400/3450 LM9832 600x1200dpi 42bit 512Kb 0x0060
98 UMAX 5400 LM9832 1200x2400dpi 42bit 512Kb 0x0160
99 .fi
100 .ft R
101 .PP
102
103 Vendor COMPAQ \- ID: 0x049F
104 .br
105 .ft CR
106 .nf
107 ----------------------------------------------------------
108 USB Model: ASIC: Properties: Prod-ID
109 ----------------------------------------------------------
110 S4-100 LM9832 600x1200dpi 42bit 512Kb 0x001A
111 .fi
112 .ft R
113 .PP
114
115 Vendor Epson \- ID: 0x04B8
116 .br
117 .ft CR
118 .nf
119 ----------------------------------------------------------
120 USB Model: ASIC: Properties: Prod-ID
121 ----------------------------------------------------------
122 Perfection 1250 LM9832 1200x2400dpi 42bit 512Kb 0x010F
123 Perfection 1260 LM9832 1200x2400dpi 42bit 512Kb 0x011D
124 .fi
125 .ft R
126 .PP
127
128 Vendor CANON \- ID: 0x04A9
129 .br
130 .ft CR
131 .nf
132 ----------------------------------------------------------
133 USB Model: ASIC: Properties: Prod-ID
134 ----------------------------------------------------------
135 CanoScan N650/656U LM9832 600x1200dpi 42bit 512Kb 0x2206
136 CanoScan N1220U LM9832 1200x2400dpi 42bit 512Kb 0x2207
137 CanoScan D660U LM9832 600x1200dpi 42bit 512Kb 0x2208
138 CanoScan N670/676U LM9833 600x1200dpi 48bit 512Kb 0x220D
139 CanoScan N1240U LM9833 1200x2400dpi 48bit 512Kb 0x220E
140 CanoScan LIDE20 LM9833 600x1200dpi 48bit 512Kb 0x220D
141 CanoScan LIDE25 LM9833 1200x2400dpi 48bit 512Kb 0x2220
142 CanoScan LIDE30 LM9833 1200x2400dpi 48bit 512Kb 0x220E
143 .fi
144 .ft R
145 .PP
146
147 Vendor Syscan \- ID: 0x0A82
148 .br
149 .ft CR
150 .nf
151 ----------------------------------------------------------
152 USB Model: ASIC: Properties: Prod-ID
153 ----------------------------------------------------------
154 Travelscan 662 LM9833 600x1200dpi 48bit 512Kb 0x6620
155 Travelscan 464 LM9833 600x1200dpi 48bit 512Kb 0x4600
156 .fi
157 .ft R
158 .PP
159
160 Vendor Portable Peripheral Co., Ltd. \- ID: 0x0A53
161 .br
162 .ft CR
163 .nf
164 ----------------------------------------------------------
165 USB Model: ASIC: Properties: Prod-ID
166 ----------------------------------------------------------
167 Q-Scan USB001 LM9832 300x600dpi 42bit 512Kb 0x1000
168 Q-Scan USB201 LM9832 300x600dpi 42bit 512Kb 0x2000
169 .fi
170 .ft R
171 .PP
172
173 Vendor Visioneer \- ID: 0x04A7
174 .br
175 .ft CR
176 .nf
177 ----------------------------------------------------------
178 USB Model: ASIC: Properties: Prod-ID
179 ----------------------------------------------------------
180 Strobe XP100 LM9833 600x1200dpi 48bit 512Kb 0x0427
181 .fi
182 .ft R
183 .PP
184
185 .SH "OTHER PLUSTEK SCANNERS"
186 For parallelport device support see the
187 .BR sane\-plustek_pp (5)
188 backend.
189 .br
190 The SCSI scanner OpticPro 19200S is a rebadged Artec AM12S scanner
191 and is supported by the
192 .BR sane\-artec (5)
193 backend.
194 .br
195 Only the National Semiconductor LM983[1/2/] based devices of Plustek
196 are supported by this backend. Older versions of the U12, the UT12,
197 the U1212 and U1248 (GrandTech chipset) are not supported.
198 .PP
199 .ft CR
200 .nf
201 Model Chipset backend
202 ------------------------------------
203 U1248 GrandTech gt68xx
204 UT16B GrandTech gt68xx
205 OpticSlim 1200 GrandTech gt68xx
206 OpticSlim 2400 GrandTech gt68xx
207 U12 P98003 u12
208 UT12 P98003 u12
209 1212U P98003 u12
210 .fi
211 .ft R
212 For a more complete and up to date list see:
213 .IR http://www.sane\-project.org/sane\-supported\-devices.html .
214
215 .SH "CONFIGURATION"
216 To use your scanner with this backend, you need at least two
217 entries in the configuration file
218 .I /etc/sane.d/plustek.conf
219 .RS
220 .PP
221 .I [usb] vendor-id product-id
222 .br
223 .I device /dev/usbscanner
224 .RE
225 .PP
226 .I [usb]
227 tells the backend, that the following devicename (here
228 .IR /dev/usbscanner )
229 has to be interpreted as USB scanner device. If vendor- and
230 product-id has not been specified, the backend tries to
231 detect this by its own. If device is set to
232 .I auto
233 then the next matching device is used.
234 .br
235 The following options can be used for a default setup of
236 your device. Most of them are also available through
237 the frontend.
238 .PP
239 .B
240 The Options:
241 .PP
242 option warmup t
243 .RS
244 .I t
245 specifies the warmup period in seconds, if set to \-1, the
246 automatic warmup function will be used
247 .RE
248 .PP
249 option lampOff t
250 .RS
251 .I t
252 is the time in seconds for switching off the lamps in
253 standby mode
254 .RE
255 .PP
256 option lOffonEnd b
257 .RS
258 .I b
259 specifies the behaviour when closing the backend, 1 --> switch
260 lamps off, 0 --> do not change lamp status
261 .RE
262 .PP
263 option mov m
264 .RS
265 .I m
266 is the model override switch. It works only with Mustek
267 BearPaw devices.
268 .br
269 .br
270 .ft CR
271 .nf
272 m/PID | 0x1000 | 0x1001
273 ------+--------------+--------------
274 0 | BearPaw 1200 | BearPaw 2400
275 1 | no function | BearPaw 1200
276 .fi
277 .ft R
278 .RE
279 .PP
280 option invertNegatives b
281 .RS
282 .I b
283 0 --> do not invert the picture during negative scans,
284 .br
285 1 --> invert picture
286 .RE
287 .PP
288 option cacheCalData b
289 .RS
290 .I b
291 0 --> do not save calibration results,
292 .br
293 1 --> save results of calibration in
294 .I ~/.sane/
295 directory
296 .RE
297 .PP
298 option altCalibration b
299 .RS
300 .I b
301 0 --> use standard calibration routines,
302 .br
303 1 --> use alternate calibration (only non Plustek devices, standard for CIS devices)
304 .RE
305 .PP
306 option skipFine b
307 .RS
308 .I b
309 0 --> perform fine calibration,
310 .br
311 1 --> skip fine calibration (only non Plustek devices)
312 .RE
313 .PP
314 option skipFineWhite b
315 .RS
316 .I b
317 0 --> perform white fine calibration,
318 .br
319 1 --> skip white fine calibration (only non Plustek devices)
320 .RE
321 .PP
322 option skipDarkStrip b
323 .RS
324 .I b
325 0 --> perform dark calibration, with enabled lamp using the
326 dark calibration strip of the scanner. If the scanner does
327 not have such a strip, the alternative way is to switch off
328 the lamp during this step.
329 .br
330 1 --> always switch off the lamp for dark calibration, even
331 a black strip is available
332 .RE
333 .PP
334 option skipCalibration b
335 .RS
336 .I b
337 0 --> perform calibration,
338 .br
339 1 --> skip calibration (only non Plustek devices)
340 .RE
341 .PP
342 option enableTPA b
343 .RS
344 .I b
345 0 --> default behaviour, specified by the internal tables,
346 .br
347 1 --> override internal tables and allow TPA mode (EPSON/UMAX only)
348 .RE
349
350 .PP
351 option posOffX x
352 .br
353 option posOffY y
354 .br
355 option tpaOffX x
356 .br
357 option tpaOffY y
358 .br
359 option negOffX x
360 .br
361 option negOffY y
362 .RS
363 .I x y
364 By using this settings, the user can adjust the given image
365 positions.
366 .B Please note, that there's no internal range checking for
367 .B this feature.
368 .RE
369 .PP
370 option posShadingY p
371 .br
372 option tpaShadingY p
373 .br
374 option negShadingY p
375 .RS
376 .I p
377 overrides the internal shading position. The values are in steps.
378 .B Please note, that there's no internal range checking for
379 .B this feature.
380 .RE
381 .PP
382 option redGamma r
383 .br
384 option greenGamma g
385 .br
386 option blueGamma b
387 .br
388 option grayGamma gr
389 .RS
390 .I r g b gr
391 .RE
392 By using these values, the internal linear gamma table (r,g,b,gr = 1.0)
393 can be adjusted.
394 .PP
395 option red_gain r
396 .br
397 option red_offset ro
398 .br
399 option green_gain g
400 .br
401 option green_offset go
402 .br
403 option blue_gain b
404 .br
405 option blue_offset bo
406 .RS
407 .I r g b ro go bo
408 These values can be used to set the gain and offset values of
409 the AFE for each channel. The range is between 0 and 63. \-1
410 means autocalibration.
411 .RE
412
413 .PP
414 See the
415 .I plustek.conf
416 file for examples.
417 .PP
418 .B Note:
419 .br
420 You have to make sure, that the USB subsystem is loaded
421 correctly and you have access to the device-node. For
422 more details see
423 .BR sane\-usb (5)
424 manpage. You might use
425 .BR sane\-find\-scanner (1)
426 to check that you have access to your device.
427 .PP
428 .B Note:
429 .br
430 If there's no configuration file, the backend defaults to
431 .B device auto
432
433 .SH FILES
434 .TP
435 .I /etc/sane.d/plustek.conf
436 The backend configuration file
437 .TP
438 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-plustek.a
439 The static library implementing this backend.
440 .TP
441 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-plustek.so
442 The shared library implementing this backend (present on systems that
443 support dynamic loading).
444
445 .SH ENVIRONMENT
446 .TP
447 .B SANE_CONFIG_DIR
448 This environment variable specifies the list of directories that may
449 contain the configuration file. On *NIX systems, the directories are
450 separated by a colon (`:'), under OS/2, they are separated by a
451 semi-colon (`;'). If this variable is not set, the configuration file
452 is searched in two default directories: first, the current working
453 directory (".") and then in
454 .IR /etc/sane.d .
455 If the value of the
456 environment variable ends with the directory separator character, then
457 the default directories are searched after the explicitly specified
458 directories. For example, setting
459 .B SANE_CONFIG_DIR
460 to "/tmp/config:" would result in directories
461 .IR "tmp/config" ,
462 .IR "." ,
463 and
464 .I "/etc/sane.d"
465 being searched (in this order).
466 .TP
467 .B SANE_DEBUG_PLUSTEK
468 If the library was compiled with debug support enabled, this
469 environment variable controls the debug level for this backend. Higher
470 debug levels increase the verbosity of the output.
471
472 Example:
473 export SANE_DEBUG_PLUSTEK=10
474
475 .SH "SEE ALSO"
476 .BR sane (7),
477 .BR sane\-usb (5),
478 .BR sane\-u12 (5),
479 .BR sane\-gt68xx (5),
480 .BR sane\-mustek_pp (5),
481 .BR sane\-find\-scanner (1),
482 .BR scanimage (1)
483 .br
484 .I /usr/share/doc/libsane/plustek/Plustek-USB.changes
485
486 .SH "CONTACT AND BUG-REPORTS"
487 Please send any information and bug-reports to:
488 .br
489 .B SANE Mailing List
490 .PP
491 Additional info and hints can be obtained from our mailing-List archive at:
492 .IR http://www.sane\-project.org/mailing\-lists.html .
493 .PP
494 To obtain debug messages from the backend, please set the
495 environment-variable
496 .B SANE_DEBUG_PLUSTEK
497 before calling your favorite SANE frontend (e.g.
498 .BR scanimage (1)):
499 .PP
500 .I export SANE_DEBUG_PLUSTEK=20 ; scanimage
501 .PP
502 The value controls the verbosity of the output. Please note that
503 values greater than 24 force the backend to output raw data files
504 which could be rather large. The suffix of these files is ".raw".
505 For problem reports it should be enough the set the verbosity to
506 13.
507
508 .SH "KNOWN BUGS & RESTRICTIONS"
509
510 .PP
511 * The driver does not support these manic scalings up
512 to 16 times the physical resolution. The only scaling
513 is done on resolutions between the physical resolution
514 of the CCD-/CIS-sensor and the stepper motor i.e. you
515 have a 600x1200 dpi scanner and you are scanning using
516 800dpi, so scaling is necessary, because the sensor only
517 delivers 600dpi but the motor is capable to perform
518 1200dpi steps.
519 .PP
520 * Plusteks' model policy is somewhat inconsistent. They
521 sell technically different devices under the
522 same product name. Therefore it is possible that some
523 devices like the UT12 or U12 won't work \- please check
524 the model list above and compare the product-id to