1 .TH sane\-microtek2 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .SH NAME
3 sane\-microtek2 \- SANE backend for Microtek scanners with SCSI-2 command set
4 .SH DESCRIPTION
5 The
6 .B sane\-microtek2
7 library implements a SANE (Scanner Access Now Easy) backend that
8 provides access to Microtek scanners with a SCSI-2 command set.
9 This backend can be considered alpha to beta. Some scanner models are reported
10 to work well, others not.
11 .PP
12 There exists a different backend for Microtek scanners with SCSI-1 command
13 set.
14 Refer to
15 .BR sane\-microtek (5)
16 for details.
17 .PP
18 And there is partial progress for the ScanMaker 3600.
19 See
20 .IR http://sourceforge.net/projects/sm3600 .
21 .PP
22 At present, the following scanners are known positively to work with this
23 backend:
24 .PP
25 .ft CR
26 .nf
27 Vendor Product id Remark
28 --------------------------------------------------------------------
29 Microtek E3+ Parport and SCSI
30 Microtek X6 SCSI
31 Microtek X6EL SCSI
32 Microtek X6USB USB
33 Microtek ScanMaker V300 Parport and SCSI
34 Microtek ScanMaker V310 Parport and SCSI
35 Microtek ScanMaker V600 Parport and SCSI
36 Microtek ScanMaker 330 SCSI
37 Microtek ScanMaker 630 SCSI
38 Microtek ScanMaker 636 SCSI
39 Microtek ScanMaker 9600XL SCSI; only flatbed mode?
40 Microtek Phantom 330CX Parport
41 Microtek SlimScan C3 Parport
42 Microtek SlimScan C6 USB
43 Microtek Phantom 636 SCSI
44 Microtek Phantom 636CX Parport
45 Microtek V6USL SCSI and USB
46 Microtek V6UPL USB; not stable
47 Microtek X12USL SCSI; only 8bit color, work in progress
48 Vobis HighScan SCSI (E3+ based models)
49 Scanport SQ300 Parport?
50 Scanport SQ4836 SCSI
51 Scanpaq SQ2030 Parport
52 .fi
53 .ft R
54 .PP
55 Additional information can be found at
56 .IR http://www.sane\-project.org/ .
57 .PP
58 If you own a Microtek scanner other than the ones listed above,
59 it may or may not work with SANE! Because equal scanners are sold under
60 different names in different countries your model may be equivalent to one of
61 the above.
62 .PP
63 The parport scanners work with the ppscsi + onscsi kernel modules. See
64 .I http://cyberelk.net/tim/parport/ppscsi.html
65 and
66 .IR http://penguin-breeder.org/kernel/download/ .
67
68 .PP
69 The USB scanners work with the microtek kernel module. You may have to add the
70 vendor and model codes to microtek.c if they aren't yet listed there.
71 .PP
72 Both parport and USB scanners need the generic SCSI support, so check if you
73 have loaded the scsi_mod and sg modules!
74 .PP
75 If you try your scanner for the first time keep an eye on it. If it gets
76 commands that it doesn't understand the scanhead may go beyond the scan area.
77 The scanner then makes strange noises. In this case immediately switch off
78 the scanner or disconnect its power cable to prevent damages!
79 .PP
80 If your scanner is a different one than the models mentioned above and it is
81 working please tell the author about it. It would be nice if you add a logfile
82 to this information (creation of the logfile: see below).
83 .PP
84 If your scanner is not working properly you also should create a logfile and
85 send it to the author. He will use the information to improve the backend and
86 possibly make your scanner work.
87 .PP
88 .br
89 How to create the logfile?
90 .TP
91 \- put the line
92 .br
93 "option dump 2" into your
94 .I microtek2.conf
95 file or change the existing "option dump" to "2"
96 .TP
97 \- in a terminal (bash) type
98 .br
99 "export SANE_DEBUG_MICROTEK2=30" and then
100 .br
101 "scanimage \-l0 \-t0 \-x100 \-y20 2>scan.log >sout.pnm"
102 .br
103 You get two files: scan.log contains the logfile and sout.pnm the scanned
104 image (if there was scanned something). Zip them before sending.
105
106 .SH "FRONTEND OPTIONS"
107 This backend dynamically enables the options for the frontend, that are
108 supported by the scanner in dependence of the scanning-mode and other
109 options.
110 Not supported options are disabled.
111 .PP
112 The following options are supported by the
113 .B sane\-microtek2
114 driver:
115 .PP
116 Color, grayscale, halftone and lineart scans.
117 .PP
118 Highlight, midtone, shadow, contrast, brightness, exposure time control,
119 gamma correction, threshold (dependent of the scan mode and the scanner
120 capabilities)
121 .PP
122 Transparency media adapter, automatic document feeder
123 .PP
124 Additional options can be enabled or disabled in the
125 .I microtek2.conf
126 file. See the configuration section of this manpage.
127
128 .SH "DEVICE NAMES"
129 This backend expects device names of the form:
130 .PP
131 .RS
132 .I special
133 .RE
134 .PP
135 Where
136 .I special
137 is the UNIX path-name for the special device that corresponds to the
138 scanner. The special device name must be a generic SCSI device or a
139 symlink to such a device. Under Linux, such a device name could be
140 .I /dev/sga
141 or
142 .I /dev/sge
143 for example.
144 .SH "CONFIGURATION"
145 The configuration file for this backend resides in
146 .IR /etc/sane.d/microtek2.conf .
147
148 Its contents is a list of device names that correspond to Microtek
149 scanners with SCSI-2 interface. Empty lines and lines starting with
150 a hash mark (#) are ignored.
151 .PP
152 The configuration file may also contain options. Global options that are valid
153 for all devices are placed above the device names. Device-specific options
154 are
155 placed under the device name. Note that, except for option dump <n> and
156 option strip-height <n>, the entry in the
157 .I microtek2.conf
158 file only enables
159 the corresponding option for being showed in the frontend. There, in the
160 frontend, you can switch the options on and off.
161 Currently the following options are supported:
162 .PP
163 .RS
164 option dump <n>
165 .br
166 option strip\-height <n>
167 .br
168 option no\-backtrack\-option <on/off>
169 .br
170 option lightlid\-35 <on/off>
171 .br
172 option toggle\-lamp <on/off>
173 .br
174 option lineart\-autoadjust <on/off>
175 .br
176 option backend\-calibration <on/off>
177 .br
178 option colorbalance\-adjust <on/off>
179 .RE
180 .PP
181 .I option dump <n>
182 enables printing of additional information about the SCSI commands that are
183 sent to the scanner to stderr. This option is primarily useful for debugging
184 purpose. This option has to be a global option and is best placed at the top
185 of the
186 .I microtek2.conf
187 file.
188 .PP
189 If n=1 the contents of the command blocks
190 and the results for the INQUIRY and READ SCANNER ATTRIBUTES command are
191 printed to stderr.
192 .PP
193 If n=2 the contents of the command blocks for all other SCSI commands are
194 printed to stderr, too. If n=3 the contents of the gamma table is
195 printed, too. If n=4 all scan data is additionally printed to stderr.
196 .PP
197 The default is n=1.
198 .PP
199 .I option strip\-height <n>
200 , where <n> is a floating point number, limits the amount of data that is
201 read from the scanner with one read command.
202 The unit is inch and <n> defaults to 1.0, if this option is not set in the
203 configuration file. If less than <n> inch of data fit into the SCSI buffer,
204 then the smaller value is used and this option has no effect.
205 .PP
206 If your system has a big SCSI buffer and you want to make use of the whole
207 buffer, increase the value for <n>. For example, if <n> is set to 14.0,
208 no restrictions apply for scanners with a letter, legal or A4 sized scan area.
209 .PP
210 .PP
211 The following options enable or disable additional frontend options. If an
212 option is set to <on> an appropriate option will appear in the frontend.
213 .PP
214 .I option no\-backtrack\-option <on/off>
215 prevents the scanner head from moving backwards between the read commands.
216 This speeds up scanning. Try it.
217 .PP
218 .I option lightlid\-35 <on/off>
219 If you use the LightLid-35 transparency adapter you get an advanced
220 option which switches off the flatbed lamp during the scan.
221 .PP
222 .I option toggle\-lamp <on/off>
223 You get a button in the frontend where you can switch on and off the flatbed
224 lamp.
225 .PP
226 .I option lineart\-autoadjust <on/off>
227 You can tell the backend to try to determine a good value for the lineart
228 threshold.
229 .PP
230 .I option backend\-calibration <on/off>
231 Some scanners (e.g. Phantom 330CX and 636CX) need to have calibrated the data
232 by the backend. Try this option if you see vertical stripes in your pictures.
233 .PP
234 .I option colorbalance\-adjust <on/off>
235 Some scanners (e.g. Phantom 330CX and 636CX) need to have corrected
236 the color balance. If this option is enabled you get advanced options
237 where you can balance the colors. And you will have a button
238 to use the values that the firmware of the scanner provides.
239 .PP
240 A sample configuration file is shown below:
241 .PP
242 .RS
243 option dump 1
244 .br
245 option strip\-height 1.0
246 .br
247 /dev/scanner
248 .br
249 option no\-backtrack\-option on
250 .br
251 # this is a comment
252 .br
253 /dev/sge
254 .br
255 option lightlid\-35 on
256 .RE
257
258 This backend also supports the new configuration file format which makes
259 it easier to detect scanners under Linux. If you have only one scanner it
260 would be best to use the following configuration file for this backend:
261 .PP
262 .RS
263 option dump 1
264 .br
265 option strip\-height 14.0
266 .br
267 option no\-backtrack\-option on
268 .br
269 option backend\-calibration on
270 .br
271 option lightlid\-35 on
272 .br
273 option toggle\-lamp on
274 .br
275 option lineart\-autoadjust on
276 .br
277 option colorbalance\-adjust off
278 .br
279 scsi * * Scanner
280 .RE
281
282 In this case all SCSI-Scanners should be detected automatically because of the
283 .PP
284 scsi * * Scanner
285 .PP
286 line.
287
288 .SH "FILES"
289 .TP
290 .I /etc/sane.d/microtek2.conf
291 The backend configuration file.
292 .TP
293 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-microtek2.a
294 The static library implementing this backend.
295 .TP
296 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-microtek2.so
297 The shared library implementing this backend (present on systems that
298 support dynamic loading).
299 .SH "ENVIRONMENT"
300 .TP
301 .B SANE_DEBUG_MICROTEK2
302 If the library was compiled with debug support enabled, this
303 environment variable controls the debug level for this backend. E.g.,
304 a value of 255 requests all debug output to be printed. Smaller
305 levels reduce verbosity. To see error messages on stderr set
306 .B SANE_DEBUG_MICROTEK2
307 to 1 (Remark: The whole debugging levels should be better revised).
308 .br
309 E.g. just say:
310 .br
311 export SANE_DEBUG_MICROTEK2=128
312
313 .SH "SEE ALSO"
314 .BR sane\-scsi(5) ,
315 .BR sane (7)
316
317 .SH "AUTHORS"
318 Bernd Schroeder (not active anymore)
319 .br
320 Karsten Festag
321 .RI < [email protected] >.