1 .TH sane\-hp 5 "13 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-hp
3 .SH NAME
4 sane\-hp \- SANE backend for HP ScanJet scanners
5 .SH DESCRIPTION
6 The
7 .B sane\-hp
8 library implements a SANE (Scanner Access Now Easy) backend that
9 provides access to HP ScanJet scanners which support SCL (Scanner
10 Control Language by HP). The following
11 scanners are known positively to work with this backend:
12 .PP
13 .RS
14 .ft CR
15 .nf
16 Model: Product id: Interface:
17 ---------- ----------- ----------
18 ScanJet Plus C9195A HP Parallel Interface Card
19 ScanJet IIc C1750A 3226 SCSI
20 ScanJet IIcx C2500A 3332 SCSI
21 ScanJet IIp C1790A SCSI
22 ScanJet 3C C2520A 3503 SCSI
23 ScanJet 3P C2570A 3406 SCSI
24 ScanJet 4C C2520A SCSI
25 ScanJet 4P C1130A 3540 SCSI
26 ScanJet 4100C C6290A USB
27 ScanJet 5P C5110A SCSI
28 ScanJet 5100C C5190A parallel port
29 ScanJet 5200C C7190A 3846 parallel port/USB
30 ScanJet 6100C C2520A 3644 SCSI
31 ScanJet 6200C C6270A 3828 SCSI/USB
32 ScanJet 6250C C6270A 3828 SCSI/USB
33 ScanJet 6300C C7670A SCSI/USB
34 ScanJet 6350C C7670A SCSI/USB
35 ScanJet 6390C C7670A SCSI/USB
36 PhotoSmart C5100A R029,R030,R032 SCSI
37 .fi
38 .ft R
39 .RE
40 .PP
41 Support for models 5100C/5200C connected to the parallel port requires
42 the ppSCSI driver available at
43 .I http://cyberelk.net/tim/parport/ppscsi.html
44 and
45 .IR http://penguin-breeder.org/kernel/download/ .
46
47 .PP
48 Support for models 5200C/62X0C/63X0C connected to USB requires
49 libusb. See
50 .BR sane\-usb (5)
51 for more details.
52 .PP
53 The
54 .B sane\-hp
55 backend no longer supports OfficeJet multi-function peripherals.
56 For these devices use the external "hplip" packages available at:
57 .IR https://developers.hp.com/hp\-linux\-imaging\-and\-printing/ .
58 For information about the previous hpoj driver, see:
59 .IR http://hpoj.sourceforge.net/ .
60 .PP
61 Because Hewlett-Packard does no longer produce scanners that support
62 SCL (beside the OfficeJets), the above list of supported scanners is
63 complete.
64 Other HP scanners are not supported by the
65 .B sane\-hp
66 backend, but might be supported by another one. See
67 .IR http://www.sane\-project.org/ .
68 You can also watch the sane\-devel mailing list at
69 .IR http://www.sane\-project.org/mailing\-lists.html .
70 .PP
71 More details about the hp backend can be found on its homepage
72 .IR http://web.archive.org/web/20070206115546/http://www.kirchgessner.net/sane.html .
73 .PP
74 .SH "DEVICE NAMES"
75 This backend expects device names of the form:
76 .PP
77 .RS
78 .I special
79 .RE
80 .PP
81 Where
82 .I special
83 is the UNIX path-name for the special device that corresponds to the
84 scanner. For SCSI scanners the special device name must be a generic SCSI
85 device or a symlink to such a device. Under Linux, such a device name could be
86 .I /dev/sga
87 or
88 .IR /dev/sg2 ,
89 for example. If the special device name contains "usb", "uscanner" or "ugen",
90 it is assumed that the scanner is connected by USB.
91 For the HP ScanJet Plus the special device name must be the device
92 that corresponds to the parallel interface card that was shipped with the
93 scanner. That is
94 .IR /dev/hpscan .
95 A special driver is required for this card.
96 See
97 .I ftp://rvs.ctrl\-c.liu.se/pub/wingel/hpscan
98 for details. If the link
99 does not work, try
100 .IR ftp://sunsite.unc.edu/pub/Linux/kernel/patches/scanners .
101 .SH CONFIGURATION
102 The contents of the
103 .I hp.conf
104 file is a list of options and device names that correspond to HP ScanJet
105 scanners. Empty lines and lines starting with a hash mark
106 (#) are ignored. See
107 .BR sane\-scsi (5)
108 and
109 .BR sane\-usb (5)
110 on details of what constitutes a valid device name.
111 .PP
112 Options specified in front of the first line that contains a device name
113 are defaults for all devices. Options specified below a line that
114 contains a device name apply just to the most recently mentioned device.
115 .PP
116 Supported options are
117 .BR connect\-scsi ,
118 .BR connect\-device ,
119 .BR enable\-image\-buffering ,
120 and
121 .BR dumb\-read .
122
123 Option
124 .B connect\-scsi
125 specifies that the scanner is connected to the system by SCSI.
126 Input/output is performed using SCSI-commands. This is the default.
127 But if your SCSI device name contains "usb", "uscanner" or "ugen",
128 option connect\-scsi must be specified. Otherwise it is assumed that
129 the scanner is connected by USB.
130
131 Option
132 .B connect\-device
133 specifies that the scanner is connected to the system by a special
134 device. Input/output is performed by
135 .BR read ()/ write "()-operations"
136 on the device. This option must be used for HP ScanJet Plus
137 or scanners connected to USB which are accessed through a named device
138 (e.g.
139 .IR /dev/usb/scanner0 ).
140 For device names that contain "usb", "uscanner" or "ugen", it is not
141 necessary to specify option connect\-device.
142
143 Option
144 .B enable\-image\-buffering
145 stores the scanned image in memory before passing it to the frontend. Could be
146 used in case of forward/backward moving scanner lamp.
147
148 Option
149 .B dumb\-read
150 can be used to work around problems with "Error during device I/O". These
151 problems may occur with certain SCSI-to-USB converters or Buslogic SCSI cards.
152 The option should not be used for SCSI devices which are working correctly.
153 Otherwise startup of frontends and changing parameters might be slower.
154 .PP
155 A sample configuration file is shown below:
156 .PP
157 .RS
158 .ft CR
159 .nf
160 /dev/scanner
161 # this is a comment
162 /dev/hpscan
163 option connect\-device
164 .fi
165 .ft R
166 .RE
167 .PP
168 .I /dev/scanner
169 is typically a symlink to the actual SCSI scanner device.
170 .RE
171 .SH FILES
172 .TP
173 .I /etc/sane.d/hp.conf
174 The backend configuration file (see also description of
175 .B SANE_CONFIG_DIR
176 below).
177 .TP
178 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-hp.a
179 The static library implementing this backend.
180 .TP
181 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-hp.so
182 The shared library implementing this backend (present on systems that
183 support dynamic loading).
184 .TP
185 .I $HOME/.sane/calib-hp:<device>.dat
186 Calibration data for HP PhotoSmart PhotoScanner that is retrieved from the
187 scanner after calibration. The data is uploaded to the scanner at start
188 of the backend if it is in media mode 'print media' or if the media mode is
189 changed to 'print media'.
190 .SH ENVIRONMENT
191 .TP
192 .B SANE_CONFIG_DIR
193 This environment variable specifies the list of directories that may
194 contain the configuration file. On *NIX systems, the directories are
195 separated by a colon (`:'), under OS/2, they are separated by a
196 semi-colon (`;'). If this variable is not set, the configuration file
197 is searched in two default directories: first, the current working
198 directory
199 .RI ( "." )
200 and then in
201 .IR /etc/sane.d .
202 If the value of the
203 environment variable ends with the directory separator character, then
204 the default directories are searched after the explicitly specified
205 directories. For example, setting
206 .B SANE_CONFIG_DIR
207 to "/tmp/config:" would result in directories
208 .IR "tmp/config" ,
209 .IR "." ,
210 and
211 .I "/etc/sane.d"
212 being searched (in this order).
213 .TP
214 .B SANE_DEBUG_HP
215 If the library was compiled with debug support enabled, this
216 environment variable controls the debug level for this backend. E.g.,
217 a value of 128 requests all debug output to be printed. Smaller
218 levels reduce verbosity.
219 .TP
220 .B SANE_HOME_HP
221 Only used for OS/2 and along with use of HP PhotoSmart PhotoScanner.
222 Must be set to the directory where the directory
223 .I .sane
224 is located. Is used to save and read the calibration file.
225 .TP
226 .B SANE_HP_KEEPOPEN_SCSI
227 .TP
228 .B SANE_HP_KEEPOPEN_USB
229 .TP
230 .B SANE_HP_KEEPOPEN_DEVICE
231 For each type of connection (connect\-scsi, connect\-usb, connect\-device)
232 it can be specified if the connection to the device should be kept open ("1")
233 or not ("0").
234 Usually the connections are closed after an operation is performed.
235 Keeping connection open to SCSI-devices can result in errors during device IO
236 when the scanner has not been used for some time. By default, USB-connections
237 are kept open. Other connections are closed.
238 .TP
239 .B SANE_HP_RDREDO
240 Specifies number of retries for read operation before returning an EOF error.
241 Only supported for non-SCSI devices. Default: 1 retry. Time between retries
242 is 0.1 seconds.
243
244 .SH BUGS
245 .TP
246 .B HP PhotoSmart PhotoScanner
247 In media mode 'slide' and 'negative', scan resolutions are rounded to
248 multiple of 300 dpi. The scanner does not scale the data correctly
249 on other resolutions. Some newer models (firmware code R030 and later)
250 do not support adjustment of contrast/intensity level and tone map.
251 The backend will simulate this by software, but only for gray
252 and 24 bit color.
253 .TP
254 .B Automatic Document Feeder (ADF)
255 For use of the ADF with
256 .BR xscanimage (1),
257 first place paper in the ADF and
258 then change option scan source to 'ADF'. Press 'change document'
259 to load a sheet. Then press 'scan' to start a scan.
260 Maybe it is sufficient to press 'scan' without 'change document'
261 for repeated scans. The use of the preview window is not recommended
262 when working with the ADF.
263 Setting a window to scan from ADF is not supported with
264 .BR xscanimage (1).
265 Try
266 .BR xsane (1).
267 .TP
268 .B Immediate actions
269 Some actions in
270 .BR xscanimage (1)
271 (i.e. unload, select media, calibrate)
272 have an immediate effect on the scanner without starting a scan.
273 These options can not be used with
274 .BR scanimage (1).
275
276 .SH TODO
277 .TP
278 .B HP PhotoSmart PhotoScanner
279 PhotoScanners with firmware release R030 and up have
280 no firmware support for contrast/brightness/gamma table. In the current
281 backend this is simulated by software on 24 bits data.
282 Simulation on 30 bits should give better results.
283 .TP
284 .B Data widths greater than 8 bits
285 Custom gamma table does not work.
286 .TP
287 .B Parallel scanner support
288 Beside the ScanJet Plus which came with its own parallel interface card,
289 currently only the HP ScanJet 5100C/5200C are supported.
290 These scanners are using an internal parallel-to-SCSI converter which
291 is supported by the ppSCSI-driver (see above).
292
293 .SH "SEE ALSO"
294 .BR sane (7),
295 .BR sane\-scsi (5),
296 .BR sane\-usb (5)
297 .BR scanimage (1),
298 .BR xscanimage (1),
299 .BR scanimage (1)
300
301 .SH AUTHOR
302 The sane\-hp backend was written by Geoffrey T. Dairiki.
303 .br