Debian Codegraph @

upstream/debian-unstable/man5/sane-lexmark.5

raw
1 .TH "sane\-lexmark" "5" "12 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-lexmark
3 .SH "NAME"
4 sane\-lexmark \- SANE backend for Lexmark X1100/X1200 Series scanners
5 .SH "DESCRIPTION"
6 The
7 .B sane\-lexmark
8 library implements a SANE (Scanner Access Now Easy) backend that
9 provides access to the scanner part of Lexmark X1100/X1200 AIOs. This backend
10 should be considered
11 .B beta-quality
12 software!
13 .PP
14 The scanners that should work with this backend are:
15 .PP
16 .RS
17 .ft CR
18 .nf
19 Vendor Model status
20 \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-
21 Lexmark X74 good
22 Lexmark X1110 untested
23 Lexmark X1140 untested
24 Lexmark X1150 good
25 Lexmark X1170 good
26 Lexmark X1180 good
27 Lexmark X1185 complete
28 Lexmark X12xx good in USB1.1,
29 not fully tested in USB2.0
30 Dell A920 good
31 .fi
32 .ft R
33 .RE
34
35 The options the backend supports can either be selected through
36 command line options to programs like
37 .BR scanimage (1)
38 or through GUI elements in
39 .BR xscanimage (1)
40 or
41 .BR xsane (1).
42
43 .br
44 If you notice any strange behavior, please report to the backend
45 maintainer or to the SANE mailing list.
46
47 Valid command line options and their syntax can be listed by using
48 .RS
49 .PP
50 scanimage \-\-help \-d lexmark:usb:<usb port>
51 .RE
52
53 .TP
54 .B Scan Mode Options
55
56 .TP
57 .B \-\-mode
58 selects the basic mode of operation of the scanner. Valid choices are
59 .IR Color ,
60 .I Gray
61 and
62 .IR Lineart .
63 The default mode is
64 .IR Color .
65 The
66 .I Lineart
67 mode is black and white only (1 bit).
68 .I Gray
69 mode will produce 256 levels of gray (8 bits).
70 .I Color
71 mode allows for over 16 million different colors produced from 24
72 bits of color information.
73
74 .TP
75 .B \-\-resolution
76 selects the resolution for a scan. The horizontal and vertical resolutions are set
77 by the value of this option. The scanner is capable of the following resolutions for the specified option value:
78 .PP
79 .RS
80 .ft CR
81 .nf
82 Value Hor. Resolution Vert. Resolution
83 \-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
84 75 75dpi 75dpi
85 150 150dpi 150dpi
86 300 300dpi 300dpi
87 600 600dpi 600dpi
88 1200 600dpi 1200dpi (only for X11xx models with 'B2' sensor)
89 .fi
90 .ft R
91 .RE
92
93 .TP
94 .B \-\-preview
95 requests a preview scan. The resolution used for that scan is 75 dpi
96 and the scan area and the scan mode are as specified through their options,
97 or the default if not specified. The default value for preview mode is "no".
98
99 .TP
100 .B \-\-threshold
101 selects the minimum-brightness to get a white point. The threshold is only used with Lineart mode scans.
102 It is specified as a percentage in the range 0..100% (in steps of 1).
103 The default value of the threshold option is 50.
104
105
106 .SH "CONFIGURATION FILE"
107 The configuration file
108 .I /etc/sane.d/lexmark.conf
109 contains only the usb device id (eg usb 0x043d 0x007c).
110
111
112 .SH "FILES"
113 .TP
114 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-lexmark.a
115 The static library implementing this backend.
116 .TP
117 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-lexmark.so
118 The shared library implementing this backend (present on systems that
119 support dynamic loading).
120
121
122 .SH "ENVIRONMENT"
123 .TP
124 .B SANE_DEBUG_LEXMARK
125 If the library was compiled with debug support enabled, this
126 environment variable controls the debug level for this backend. E.g.,
127 a value of 255 requests all debug output to be printed. Smaller levels
128 reduce verbosity.
129 .TP
130 .B SANE_DEBUG_LEXMARK_LOW
131 Provides debug output for low level Lexmark functions.
132
133 .SH "LIMITATIONS"
134 The windows TWAIN driver has many more options than this SANE
135 backend. However they are only software adjustments. This backend only
136 implements what the scanner can support. For instance, shading correction
137 (vertical stripes due to sensor variation across its width) is done in
138 software. Head park position is also detected by software.
139 The data compression isn't supported for the X1200 series on USB 1.1,
140 leading to slow scans.
141
142 .SH "BUGS"
143 .br
144 No bugs currently known.
145
146
147
148 .SH "SEE ALSO"
149 .BR sane\-scsi (5),
150 .BR scanimage (1),
151 .BR xscanimage (1),
152 .BR xsane (1),
153 .BR sane (7)
154
155
156 .SH "AUTHOR"
157 .TP
158 The backend was originally written by Fred Odendaal.
159 .I http://ca.geocities.com/[email protected]/
160 .TP
161 The new version is currently developed by St\['e]phane Voltz.
162 .I http://stef.dev.free.fr/sane/lexmark
163 .TP
164 X74 support was written by Torsten Houwaart
165 .RI < [email protected] >
166
167 .SH "CREDITS"
168 .TP
169 Many thanks go to:
170 Julien Furgerot who lent me a Dell A920.
171 Robert Price, Dani Ele and Dalai Felinto for the time they spent recording
172 USB activity and testing the experimental version.