| 1 |
.TH "sane\-lexmark" "5" "12 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-lexmark |
| 3 |
.SH "NAME" |
| 4 |
sane\-lexmark \- SANE backend for Lexmark X1100/X1200 Series scanners |
| 5 |
.SH "DESCRIPTION" |
| 6 |
The |
| 7 |
.B sane\-lexmark |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that |
| 9 |
provides access to the scanner part of Lexmark X1100/X1200 AIOs. This backend |
| 10 |
should be considered |
| 11 |
.B beta-quality |
| 12 |
software! |
| 13 |
.PP |
| 14 |
The scanners that should work with this backend are: |
| 15 |
.PP |
| 16 |
.RS |
| 17 |
.ft CR |
| 18 |
.nf |
| 19 |
Vendor Model status |
| 20 |
\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\- |
| 21 |
Lexmark X74 good |
| 22 |
Lexmark X1110 untested |
| 23 |
Lexmark X1140 untested |
| 24 |
Lexmark X1150 good |
| 25 |
Lexmark X1170 good |
| 26 |
Lexmark X1180 good |
| 27 |
Lexmark X1185 complete |
| 28 |
Lexmark X12xx good in USB1.1, |
| 29 |
not fully tested in USB2.0 |
| 30 |
Dell A920 good |
| 31 |
.fi |
| 32 |
.ft R |
| 33 |
.RE |
| 34 |
|
| 35 |
The options the backend supports can either be selected through |
| 36 |
command line options to programs like |
| 37 |
.BR scanimage (1) |
| 38 |
or through GUI elements in |
| 39 |
.BR xscanimage (1) |
| 40 |
or |
| 41 |
.BR xsane (1). |
| 42 |
|
| 43 |
.br |
| 44 |
If you notice any strange behavior, please report to the backend |
| 45 |
maintainer or to the SANE mailing list. |
| 46 |
|
| 47 |
Valid command line options and their syntax can be listed by using |
| 48 |
.RS |
| 49 |
.PP |
| 50 |
scanimage \-\-help \-d lexmark:usb:<usb port> |
| 51 |
.RE |
| 52 |
|
| 53 |
.TP |
| 54 |
.B Scan Mode Options |
| 55 |
|
| 56 |
.TP |
| 57 |
.B \-\-mode |
| 58 |
selects the basic mode of operation of the scanner. Valid choices are |
| 59 |
.IR Color , |
| 60 |
.I Gray |
| 61 |
and |
| 62 |
.IR Lineart . |
| 63 |
The default mode is |
| 64 |
.IR Color . |
| 65 |
The |
| 66 |
.I Lineart |
| 67 |
mode is black and white only (1 bit). |
| 68 |
.I Gray |
| 69 |
mode will produce 256 levels of gray (8 bits). |
| 70 |
.I Color |
| 71 |
mode allows for over 16 million different colors produced from 24 |
| 72 |
bits of color information. |
| 73 |
|
| 74 |
.TP |
| 75 |
.B \-\-resolution |
| 76 |
selects the resolution for a scan. The horizontal and vertical resolutions are set |
| 77 |
by the value of this option. The scanner is capable of the following resolutions for the specified option value: |
| 78 |
.PP |
| 79 |
.RS |
| 80 |
.ft CR |
| 81 |
.nf |
| 82 |
Value Hor. Resolution Vert. Resolution |
| 83 |
\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\- |
| 84 |
75 75dpi 75dpi |
| 85 |
150 150dpi 150dpi |
| 86 |
300 300dpi 300dpi |
| 87 |
600 600dpi 600dpi |
| 88 |
1200 600dpi 1200dpi (only for X11xx models with 'B2' sensor) |
| 89 |
.fi |
| 90 |
.ft R |
| 91 |
.RE |
| 92 |
|
| 93 |
.TP |
| 94 |
.B \-\-preview |
| 95 |
requests a preview scan. The resolution used for that scan is 75 dpi |
| 96 |
and the scan area and the scan mode are as specified through their options, |
| 97 |
or the default if not specified. The default value for preview mode is "no". |
| 98 |
|
| 99 |
.TP |
| 100 |
.B \-\-threshold |
| 101 |
selects the minimum-brightness to get a white point. The threshold is only used with Lineart mode scans. |
| 102 |
It is specified as a percentage in the range 0..100% (in steps of 1). |
| 103 |
The default value of the threshold option is 50. |
| 104 |
|
| 105 |
|
| 106 |
.SH "CONFIGURATION FILE" |
| 107 |
The configuration file |
| 108 |
.I /etc/sane.d/lexmark.conf |
| 109 |
contains only the usb device id (eg usb 0x043d 0x007c). |
| 110 |
|
| 111 |
|
| 112 |
.SH "FILES" |
| 113 |
.TP |
| 114 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-lexmark.a |
| 115 |
The static library implementing this backend. |
| 116 |
.TP |
| 117 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-lexmark.so |
| 118 |
The shared library implementing this backend (present on systems that |
| 119 |
support dynamic loading). |
| 120 |
|
| 121 |
|
| 122 |
.SH "ENVIRONMENT" |
| 123 |
.TP |
| 124 |
.B SANE_DEBUG_LEXMARK |
| 125 |
If the library was compiled with debug support enabled, this |
| 126 |
environment variable controls the debug level for this backend. E.g., |
| 127 |
a value of 255 requests all debug output to be printed. Smaller levels |
| 128 |
reduce verbosity. |
| 129 |
.TP |
| 130 |
.B SANE_DEBUG_LEXMARK_LOW |
| 131 |
Provides debug output for low level Lexmark functions. |
| 132 |
|
| 133 |
.SH "LIMITATIONS" |
| 134 |
The windows TWAIN driver has many more options than this SANE |
| 135 |
backend. However they are only software adjustments. This backend only |
| 136 |
implements what the scanner can support. For instance, shading correction |
| 137 |
(vertical stripes due to sensor variation across its width) is done in |
| 138 |
software. Head park position is also detected by software. |
| 139 |
The data compression isn't supported for the X1200 series on USB 1.1, |
| 140 |
leading to slow scans. |
| 141 |
|
| 142 |
.SH "BUGS" |
| 143 |
.br |
| 144 |
No bugs currently known. |
| 145 |
|
| 146 |
|
| 147 |
|
| 148 |
.SH "SEE ALSO" |
| 149 |
.BR sane\-scsi (5), |
| 150 |
.BR scanimage (1), |
| 151 |
.BR xscanimage (1), |
| 152 |
.BR xsane (1), |
| 153 |
.BR sane (7) |
| 154 |
|
| 155 |
|
| 156 |
.SH "AUTHOR" |
| 157 |
.TP |
| 158 |
The backend was originally written by Fred Odendaal. |
| 159 |
.I http://ca.geocities.com/[email protected]/ |
| 160 |
.TP |
| 161 |
The new version is currently developed by St\['e]phane Voltz. |
| 162 |
.I http://stef.dev.free.fr/sane/lexmark |
| 163 |
.TP |
| 164 |
X74 support was written by Torsten Houwaart |
| 165 |
.RI < [email protected] > |
| 166 |
|
| 167 |
.SH "CREDITS" |
| 168 |
.TP |
| 169 |
Many thanks go to: |
| 170 |
Julien Furgerot who lent me a Dell A920. |
| 171 |
Robert Price, Dani Ele and Dalai Felinto for the time they spent recording |
| 172 |
USB activity and testing the experimental version. |