Debian Codegraph @

upstream/debian-unstable/man5/sane-coolscan2.5

raw
1 .TH sane\-coolscan2 5 "11 Jul 2008" "" "SANE Scanner Access Now Easy"
2 .IX sane\-coolscan2
3 .SH NAME
4 sane\-coolscan2 \- SANE backend for Nikon Coolscan film scanners
5 .SH DESCRIPTION
6 The
7 .B sane\-coolscan2
8 library implements a SANE (Scanner Access Now Easy) backend that
9 provides access to Nikon Coolscan film scanners. Some functions of this
10 backend should be considered
11 .B beta-quality
12 software. Most functions have been stable for a long time, but of
13 course new development can not and will not function properly from
14 the very first day. Please report any strange behaviour to the
15 maintainer of the backend.
16
17 .PP
18 At present, the following scanners are known to work with this backend:
19 .PP
20 .RS
21 .ft CR
22 .nf
23 Model: Connection Type
24 --------------------------- -------------------
25 LS-30 (Coolscan III) SCSI
26 LS-2000 SCSI
27 LS-40 ED (Coolscan IV) USB
28 LS-4000 ED IEEE 1394
29 LS-8000 ED IEEE 1394
30 .fi
31 .ft R
32 .RE
33
34 Please send mail to the backend author ([email protected]) to
35 report successes or failures.
36
37 .SH OPTIONS
38 The options the backend supports can either be selected through command line
39 options to programs like
40 .BR scanimage (1)
41 or through GUI elements in
42 .BR xscanimage (1)
43 or
44 .BR xsane (1).
45
46 Valid command line options and their syntax can be listed by using:
47 .PP
48 .RS
49 scanimage \-\-help \-d coolscan2:<interface>:<device>
50 .RE
51 .PP
52 where <interface> and <device> specify the device in question, as in the
53 configuration file (see next section). The
54 .B \-d
55 parameter and its argument
56 can be omitted to obtain information on the first scanner identified. Use
57 the command:
58 .PP
59 .RS
60 scanimage \-L
61 .RE
62 .PP
63 to list all devices recognized by your SANE installation.
64
65 The options should be fully described by the description or tooltips given by
66 frontend. Here is a description of some of the most important options, in the
67 syntax with which they must be supplied to
68 .BR scanimage (1):
69 .TP
70 .B \-\-frame <n>
71 This option specifies which frame to operate on, if a motorized film strip
72 feeder or APS adapter are used. The frame number
73 .I <n>
74 ranges from 1 to the number of frames available, which is sensed each time
75 the backend is initialized (usually each time you start the frontend).
76 .TP
77 .B \-\-subframe <x>
78 This option shifts the scan window by the specified amount (default
79 unit is mm).
80 .TP
81 .B \-\-infrared=yes/no
82 If set to "yes", the scanner will read the infrared channel, thus allowing
83 defect removal in software. The infrared image is read during a second scan,
84 with no options altered. The backend must not be restarted between the scans.
85 If you use
86 .BR scanimage (1),
87 perform a batch scan with
88 .B \-\-batch\-count=2
89 to obtain the IR information.
90 .TP
91 .B \-\-depth <n>
92 Here <n> can either be 8 or the maximum number of bits supported by the
93 scanner (10, 12, or 14). It specifies whether or not the scanner reduces
94 the scanned data to 8 bits before sending it to the backend. If 8 bits are
95 used, some information and thus image quality is lost, but the amount of data
96 is smaller compared to higher depths. Also, many imaging programs and image
97 formats cannot handle depths greater than 8 bits.
98 .TP
99 .B \-\-autofocus
100 Perform autofocus operation. Unless otherwise specified by the other options (
101 .B \-\-focus\-on\-centre
102 and friends), focusing is performed on the centre of the selected scan area.
103 .TP
104 .B \-\-ae\-wb
105 .TP
106 .B \-\-ae
107 Perform a pre-scan to calculate exposure values automatically.
108 .B \-\-ae\-wb
109 will maintain the white balance, while
110 .B \-\-ae
111 will adjust each channel separately.
112 .TP
113 .B \-\-exposure
114 Multiply all exposure times with this value. This allows exposure
115 correction without modifying white balance.
116 .TP
117 .B \-\-load
118 Load the next slide when using the slide loader
119 (applies only to the SF\-200 bulk feeder).
120 .TP
121 .B \-\-eject
122 Eject the film strip or mounted slide when using the slide loader.
123 .TP
124 .B \-\-reset
125 Reset scanner. The scanner will perform the same action as when power is
126 turned on: it will eject the slide (with the SF\-200 bulk feeder)
127 and calibrate itself. Use this whenever the scanner refuses to load
128 a slide properly, as a result of
129 which
130 .B \-\-eject
131 does not work.
132
133 .SH CONFIGURATION FILE
134 The configuration file
135 .I /etc/sane.d/coolscan2.conf
136 specifies the device(s)
137 that the backend will use. Owing to the nature of the supported connection
138 types SCSI, USB, and IEEE 1394, the default configuration file supplied with
139 the SANE distribution should work without being edited.
140
141 Each line in the configuration file is either of the following, where all
142 entries are case-sensitive:
143 .TP
144 .I blank or starting with a '#' character
145 These lines are ignored, thus '#' can be used to include comments.
146 .TP
147 .I containing only the word """auto"""
148 This instructs the backend to probe for a scanner by scanning the buses for
149 devices with known identifiers. This is the default action when no
150 configuration file is present.
151 .TP
152 .I a line of the form <interface>:<device>
153 Here <interface> can be one of "scsi" or "usb", and <device> is the device
154 file of the scanner. Note that IEEE 1394 devices are handled by the SBP-2
155 module in the kernel and appear to SANE as SCSI devices.
156
157 .SH FILES
158 .TP
159 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan2.a
160 The static library implementing this backend.
161 .TP
162 .I /usr/lib/x86_64-linux-gnu/sane/libsane\-coolscan2.so
163 The shared library implementing this backend (present on systems that
164 support dynamic loading).
165 .TP
166 .I /etc/sane.d/coolscan2.conf
167 Configuration file for this backend, read each time the backend is
168 initialized.
169
170 .SH ENVIRONMENT
171 .TP
172 .B SANE_DEBUG_COOLSCAN2
173 If the library was compiled with debug support enabled, this
174 environment variable controls the debug level for this backend. E.g.,
175 a value of 128 requests all debug output to be printed. Smaller
176 levels reduce verbosity.
177
178 .SH "SEE ALSO"
179 .BR sane\-scsi (5),
180 .BR sane\-usb (5),
181 .BR scanimage (1),
182 .BR xscanimage (1),
183 .BR xsane (1)
184
185 .SH BUGS
186 Currently, the SANE protocol does not allow automatically updating options
187 whenever the hardware changes. Thus the number of choices for the
188 .B \-\-frame
189 option will be fixed when the backend is initialized (usually when the user
190 runs the frontend). In particular, if there is no film strip in the
191 automatic film strip feeder when the backend is initialized, the
192 .B \-\-frame
193 option will not appear at all. Also, restarting the frontend after swapping film
194 adapters is strongly recommended.
195
196 Linux kernels prior to 2.4.19 had a patch that truncated INQUIRY data
197 from IEEE 1394 scanners to 36 bytes, discarding vital information
198 about the scanner. The IEEE 1394 models therefore only work with
199 2.4.19 or later.
200
201 No real bugs currently known, please report any to the backend maintainer
202 or the SANE developers' email list.
203
204 .SH AUTHORS
205 The backend is written and maintained by Andr\['a]s Major
206 .IR <[email protected]> .