| 1 |
.TH sane\-canon_pp 5 "11 Jul 2008" "" "SANE Scanner Access Now Easy" |
| 2 |
.IX sane\-canon_pp |
| 3 |
.SH NAME |
| 4 |
sane\-canon_pp \- SANE backend for Canon CanoScan Parallel Port flatbed scanners |
| 5 |
.SH DESCRIPTION |
| 6 |
The |
| 7 |
.B sane\-canon_pp |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that provides |
| 9 |
access to the following Canon flatbed scanners: |
| 10 |
.PP |
| 11 |
.RS |
| 12 |
CanoScan FB320P |
| 13 |
.br |
| 14 |
CanoScan FB620P |
| 15 |
.br |
| 16 |
CanoScan FB330P |
| 17 |
.br |
| 18 |
CanoScan FB630P |
| 19 |
.br |
| 20 |
CanoScan N340P |
| 21 |
.br |
| 22 |
CanoScan N640P |
| 23 |
.br |
| 24 |
CanoScan N640P ex |
| 25 |
.br |
| 26 |
.RE |
| 27 |
.PP |
| 28 |
No USB scanners are supported and there are no plans to support them in the |
| 29 |
future. Other projects are working on support for USB scanners. See the |
| 30 |
.I PROJECTS |
| 31 |
file for more detail. The FB310P and FB610P are re-badged Avision scanners |
| 32 |
which use a different command set, so are unlikely to be supported by this |
| 33 |
backend in the future. |
| 34 |
.PP |
| 35 |
IMPORTANT: this is alpha code. While we have made every effort to make it as |
| 36 |
reliable as possible, it will not always work as expected. Feedback is still |
| 37 |
appreciated. Please send any bug reports to the maintainers as listed on the |
| 38 |
web page (listed in |
| 39 |
.B SEE ALSO |
| 40 |
below). |
| 41 |
|
| 42 |
.SH "DEVICE NAMES" |
| 43 |
This backend expects device names of the form presented by |
| 44 |
.BR libieee1284 (3). |
| 45 |
These names are highly dependent on operating system and version. |
| 46 |
|
| 47 |
On Linux 2.4 kernels this will be of the form |
| 48 |
.I "parport0" |
| 49 |
or older (2.2 and before) kernels may produce names like |
| 50 |
.IR "0x378" |
| 51 |
(the base address of your port) or simply |
| 52 |
.IR "0" |
| 53 |
depending on your module configuration. Check the contents of |
| 54 |
.I /proc/parport |
| 55 |
if it exists. If you don't want to specify a default port (or don't know its |
| 56 |
name), the backend should be able to detect which port your scanner is on. |
| 57 |
|
| 58 |
.SH CONFIGURATION |
| 59 |
The contents of the |
| 60 |
.I canon_pp.conf |
| 61 |
file is a list of options for the driver to use. Empty lines and lines |
| 62 |
starting with a hash mark (#) are ignored. |
| 63 |
.PP |
| 64 |
The supported options are currently |
| 65 |
.BR ieee1284 , |
| 66 |
.BR calibrate , |
| 67 |
.BR init_mode , |
| 68 |
and |
| 69 |
.BR force_nibble |
| 70 |
|
| 71 |
.TP |
| 72 |
.B ieee1284 port-name |
| 73 |
Defines which port to use. The format of port-name is OS dependent, based on |
| 74 |
the names presented by |
| 75 |
.BR libieee1284 (3). |
| 76 |
Please only have one of these lines, or |
| 77 |
all but one will be ignored. |
| 78 |
|
| 79 |
.TP |
| 80 |
.B calibrate cal-file [port-name] |
| 81 |
Defines which calibration file to use on a per-port basis. If you only have |
| 82 |
one parport, the port-name argument may be omitted \- but be careful as this |
| 83 |
will cause problems on multi-scanner systems. You may have as many of these |
| 84 |
lines as you like, as long as each has a unique port name. The tilde (`~') |
| 85 |
character is acceptable and will be expanded to the value of the |
| 86 |
.B HOME |
| 87 |
environment variable. |
| 88 |
|
| 89 |
.TP |
| 90 |
.B init_mode <AUTO|FB620P|FB630P> [port-name] |
| 91 |
Defines which initialisation (wake-up) mode to use on a per-port basis. |
| 92 |
If you only have one parport, the port-name argument may be omitted \- but |
| 93 |
be careful as this may cause problems on multi-scanner systems. |
| 94 |
You may have as many of these lines as you like, as long as each has a unique |
| 95 |
port name. The valid initialisation modes are FB620P (which strobes 10101010 |
| 96 |
and 01010101 on the data pins), FB630P (which strobes 11001100 and 00110011 |
| 97 |
on the data pins) and AUTO, which will try FB630P mode first then FB620P mode |
| 98 |
second. The FB620P mode is also used by the FB320P. The FB630P mode is used |
| 99 |
by the FB330P, N340P, and N640P. |
| 100 |
|
| 101 |
.TP |
| 102 |
.B force_nibble |
| 103 |
Forces the driver to use nibble mode even if ECP mode is reported to work by |
| 104 |
.BR libieee1284 (3). |
| 105 |
This works-around the rare issue of ECP mode being reported to |
| 106 |
work by the library, then not working. |
| 107 |
|
| 108 |
.SH TIPS |
| 109 |
.PP |
| 110 |
Hit the "Calibrate" button before scanning. It vastly improves the quality of |
| 111 |
scans. |
| 112 |
.PP |
| 113 |
To enable automatic detection of your scanner, uncomment the "canon_pp" line |
| 114 |
from |
| 115 |
.I /etc/sane.d/dll.conf |
| 116 |
.PP |
| 117 |
.SH FILES |
| 118 |
.TP |
| 119 |
.I /etc/sane.d/canon_pp.conf |
| 120 |
The backend configuration file (see also description of |
| 121 |
.B SANE_CONFIG_DIR |
| 122 |
below). |
| 123 |
.TP |
| 124 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-canon_pp.a |
| 125 |
The static library implementing this backend. |
| 126 |
.TP |
| 127 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-canon_pp.so |
| 128 |
The shared library implementing this backend (present on systems that support |
| 129 |
dynamic loading). |
| 130 |
.SH ENVIRONMENT |
| 131 |
.TP |
| 132 |
.B SANE_CONFIG_DIR |
| 133 |
This environment variable specifies the list of directories that may contain |
| 134 |
the configuration file. On *NIX systems, the directories are separated by a colon |
| 135 |
(`:'), under OS/2, they are separated by a semi-colon (`;'). If this variable |
| 136 |
is not set, the configuration file is searched in two default directories: |
| 137 |
first, the current working directory (".") and then in |
| 138 |
.IR /etc/sane.d . |
| 139 |
If the value of the environment variable ends with the directory separator |
| 140 |
character, then the default directories are searched after the explicitly |
| 141 |
specified directories. For example, setting |
| 142 |
.B SANE_CONFIG_DIR |
| 143 |
to "/tmp/config:" would result in directories |
| 144 |
.IR tmp/config , |
| 145 |
.IR . , |
| 146 |
and |
| 147 |
.I /etc/sane.d |
| 148 |
being searched (in this order). |
| 149 |
.TP |
| 150 |
.B SANE_DEBUG_CANON_PP |
| 151 |
If the library was compiled with debug support enabled, this environment |
| 152 |
variable controls the debug level for this backend. Higher debug levels |
| 153 |
increase the verbosity of the output. |
| 154 |
|
| 155 |
Example: |
| 156 |
export SANE_DEBUG_CANON_PP=4 |
| 157 |
.SH NOTES |
| 158 |
.B Features available in the Windows interface |
| 159 |
.TP |
| 160 |
.B Brightness and Contrast |
| 161 |
These are not implemented, and probably never will be. These appear to be |
| 162 |
implemented entirely in software. Use GIMP or a similar program if you need |
| 163 |
these features. |
| 164 |
.TP |
| 165 |
.B Descreen Mode |
| 166 |
This appears on our first analysis to be just oversampling with an |
| 167 |
anti-aliasing filter. Again, it seems to be implemented entirely in software, |
| 168 |
so GIMP is your best bet for now. |
| 169 |
.TP |
| 170 |
.B Gamma Tables |
| 171 |
This is under investigation, but for now only a simple gamma profile (ie: the |
| 172 |
one returned during calibration) will be loaded. |
| 173 |
.PP |
| 174 |
.B Communication Problems |
| 175 |
.PP |
| 176 |
ECP mode in |
| 177 |
.BR libieee1284 (3) |
| 178 |
doesn't always work properly, even with new hardware. |
| 179 |
We believe that this is a ppdev problem. If you change the configuration file |
| 180 |
to include |
| 181 |
.B force_nibble |
| 182 |
, the problem will go away, but you will only be able to scan in nibble mode. |
| 183 |
.PP |
| 184 |
Sometimes the scanner can be left in a state where our code cannot revive it. |
| 185 |
If the backend reports no scanner present, try unplugging the power and |
| 186 |
plugging it back in. Also try unplugging printers from the pass-through port. |
| 187 |
.PP |
| 188 |
The scanner will not respond correctly to our commands when you first plug in |
| 189 |
the power. You may find if you try a scan very soon after plugging in the |
| 190 |
power that the backend will incorrectly report that you have no scanner present. |
| 191 |
To avoid this, give it about 10 seconds to reset itself before attempting any |
| 192 |
scans. |
| 193 |
.PP |
| 194 |
.B Repeated Lines |
| 195 |
.PP |
| 196 |
Sometimes at high resolutions (ie. 600dpi) you will notice lines which appear |
| 197 |
twice. These lines correspond to points where the scanner head has stopped |
| 198 |
during the scan (it stops every time the internal 64kb buffer is full). |
| 199 |
Basically it's a mechanical problem inside the scanner, that the tolerance of |
| 200 |
movement for a start/stop event is greater than 1/600 inches. I've never tried |
| 201 |
the windows driver so I'm not sure how (or if) it works around this problem, |
| 202 |
but as we don't know how to rewind the scanner head to do these bits again, |
| 203 |
there's currently no nice way to deal with the problem. |
| 204 |
.PP |
| 205 |
.B Grey-scale Scans |
| 206 |
.PP |
| 207 |
Be aware that the scanner uses the green LEDs to read grey-scale scans, meaning |
| 208 |
green coloured things will appear lighter than normal, and red and blue |
| 209 |
coloured items will appear darker than normal. For high-accuracy grey-scale |
| 210 |
scans of colour items, it's best just to scan in colour and convert to |
| 211 |
grey-scale in graphics software such as the GIMP. |
| 212 |
.PP |
| 213 |
.B FB620P/FB320P Caveats |
| 214 |
.PP |
| 215 |
These models can not be reset in the same way as the others. The windows driver |
| 216 |
doesn't know how to reset them either \- when left with an inconsistent scanner, |
| 217 |
it will start scanning half way down the page! |
| 218 |
.PP |
| 219 |
Aborting is known to work correctly on the FB*30P models, and is known to be |
| 220 |
broken on the FB*20P models. The FB620P which I tested on simply returns |
| 221 |
garbage after a scan has been aborted using the method we know. |
| 222 |
Aborting is able to leave the scanner in a state where it can be shut down, |
| 223 |
but not where another scan can be made. |
| 224 |
|
| 225 |
|
| 226 |
.SH "SEE ALSO" |
| 227 |
.BR sane (7), |
| 228 |
.BR sane\-dll(5), |
| 229 |
.BR libieee1284 (3), |
| 230 |
.br |
| 231 |
.I http://canon\-fb330p.sourceforge.net/ |
| 232 |
|
| 233 |
.SH AUTHOR |
| 234 |
This backend is primarily the work of Simon Krix (Reverse Engineering), and |
| 235 |
Matthew Duggan (SANE interface). |
| 236 |
.PP |
| 237 |
Many thanks to Kevin Easton for his comments and help, and Kent A. Signorini |
| 238 |