Debian Codegraph @

eyes17/helpFiles/hi/_sources/2.14.rst

raw
1 Light dependent resistors
2 =========================
3
4 The resistance of an LDR reduces with the intensity of light falling on it.
5 This can be measured using the SEN terminal.
6
7 Objective
8 ---------
9
10 Learn about LDR. Measure intensity of light and its variation with distance from the source.
11
12 .. image:: schematics/ldr.svg
13 :width: 300px
14
15 Procedure
16 ---------
17
18 - Connect the LDR from SEN to ground
19 - Connect a wire from SEN to A1
20 - Measure the LDR’s resistance, for different light intensities.
21 - Iluminate LDR using a fluorescent lamp, A1 should show ripples
22 - Set the time base to 200mS full scale
23 - Put A1 in AC mode, using the switch, and measure ripple frequency
24
25 Discussion
26 ----------
27
28 The resistance vary from 1kΩ to around 100 kΩ depending on the intensity
29 of light falling on it. The voltage is proportional to the resistance.
30 The resistance decreases with intensity of light. If you use a point
31 source of light, the resistance should increase as the square of the
32 distance between the LDR and the light source. The light from a fluorescent lamp operating at 50Hz
33 has 100Hz ripples and these can be measured.