1 The main GUI program
2 ====================
3
4 Start Applications->Education->ExpEYES-17 from the menu. A four channel
5 oscilloscope screen with several extra features will open as shown in
6 the figure. Various experiments can be selected from the menu.
7
8 .. _the-scope17-screen:
9 .. figure:: pics/eyes17-screen.png
10
11 The ExpEYES-17 main GUI
12
13 The main window looks like a low frequency four channel oscilloscope,
14 with some extra features, on the right side panel. Applications for
15 various experiments can be selected from the pulldown menu. A brief
16 description of the oscilloscope program is given below.
17
18 - Any of the four inputs (A1, A2, A3 or MIC) can be enabled using the
19 corresponding checkbox. The input range can be selected by clicking
20 on the menubutton on the right side of the checkbox. Select the
21 desired input range from the popup menu.
22 - There is another checkbox, to enable mathematical fitting of the data
23 using :math:`V=V_0 sin(2\pi f t + \theta )+C` to show the amplitude and
24 frequency.
25 - The horizontal scale (time base) can be changed by a slider, from .5
26 mS fullscale to 500 mS full scale.
27 - The Checkbutton **Freeze**, allows to pause and resume the
28 oscilloscope operation.
29 - The Trigger level can be set by a slider, and there is a menubutton
30 to select the trigger source.
31 - To save the traces to a file, edit the filename and click on the
32 **SaveTo** button.
33 - Clicking on **FFT** shows the frequency spectrum of all the eneabled
34 channels, appears on popup windows.
35
36 In addition to the Oscilloscope, there are several measurement/control
37 options available on the GUI, they are explained below.
38
39 - If selected, the voltages at the inputs A1, A2 and A3 are sampled
40 every second and displayed.
41 - The resistance connected between SEN and Ground is measured and
42 displayed every second.
43 - Clicking **Capacitance on IN1**, measures the value of the capacitor
44 connected between IN1 and GND.
45 - Clicking **Frequency on IN2**, measures the frequency of an external
46 digital (TTL standard) pulse connected to IN2
47 - The shape of the waveform can be selected using the menubutton,
48 default shape is sine. It can be changed to triangular. When the
49 square wave option is selected, the output is shifted to SQ2. You
50 cannot have sine/triangular and SQ2 at the same time.
51 - Frequency of the Waveform generator WG can be set using the slider or
52 the text entry window. The two input methods follow each other,
53 changing the slider will change the text field and entering data
54 using text field will set the slider to that value. The frequency
55 will be set to the nearest possible value and it will be displayed in
56 the message window at the bottom. The amplitude of WG output can be
57 set to 3 volts, 1 volt or 80 mV.
58 - SQ1 can be set using the same method as explained above. The duty
59 cycle can be set between 1% to 99%, default is 50%.
60 - The programmable volages PV1 and PV2 are also set in a similar
61 manner.
62 - Checkbuttons are provided to control OD1 and CCS.
63
64 The top menu of the Main Window
65 ===============================
66
67 The top of the window contains a menu to change the current experimental
68 setup: every entry in this menu is a category of experiments, like
69 School experiments, Electronics, Electrical, and so on... except the
70 leftmost entry "Device", which contains special commands.
71
72 The Device submenus
73 -------------------
74
75 When one triggers the "Device" menu, new submenus appear:
76
77 - **Reconnect**: try to synchronize the computer and Eyes17 after
78 a reconnection.
79 - **Light Background**: allows one to use a light background to
80 display the traces. Any selected experiment is forgotten, and the
81 default user interface is re-initialised instead.
82 - **Dark Background**: it is the same, but one gets a dark background to
83 display the traces.
84 - **Choose language**: this allows one to select the language for the
85 user interface and for the help files.
86 - **Screen shot**: one can take a snapshot from the complete Graphic User
87 Interface, or just from the oscilloscope's display (respective keyboard
88 shortcuts are `Alt-S` and `Alt-P`). In the special case when English
89 language and Dark Background are set, an additional dialog will let
90 one create automatically a set of snapshots translated to every
91 language supported by Eyes17, on dark and on light backgrounds, in
92 SVG (vectorial) and PNG (pixmap) formats. This feature is rather