| 1 |
Kernel driver tmp102 |
| 2 |
==================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Texas Instruments TMP102 |
| 7 |
|
| 8 |
Prefix: 'tmp102' |
| 9 |
|
| 10 |
Addresses scanned: none |
| 11 |
|
| 12 |
Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html |
| 13 |
|
| 14 |
Author: |
| 15 |
|
| 16 |
Steven King <[email protected]> |
| 17 |
|
| 18 |
Description |
| 19 |
----------- |
| 20 |
|
| 21 |
The Texas Instruments TMP102 implements one temperature sensor. Limits can be |
| 22 |
set through the Overtemperature Shutdown register and Hysteresis register. The |
| 23 |
sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0 |
| 24 |
degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The |
| 25 |
operating temperature has a minimum of -55 C and a maximum of +150 C. |
| 26 |
|
| 27 |
The TMP102 has a programmable update rate that can select between 8, 4, 1, and |
| 28 |
0.5 Hz. (Currently the driver only supports the default of 4 Hz). |
| 29 |
|
| 30 |
The driver provides the common sysfs-interface for temperatures (see |
| 31 |