| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
Kernel driver pli1209bc |
| 4 |
======================= |
| 5 |
|
| 6 |
Supported chips: |
| 7 |
|
| 8 |
* Digital Supervisor PLI1209BC |
| 9 |
|
| 10 |
Prefix: 'pli1209bc' |
| 11 |
|
| 12 |
Addresses scanned: 0x50 - 0x5F |
| 13 |
|
| 14 |
Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf |
| 15 |
|
| 16 |
Authors: |
| 17 |
- Marcello Sylvester Bauer <[email protected]> |
| 18 |
|
| 19 |
Description |
| 20 |
----------- |
| 21 |
|
| 22 |
The Vicor PLI1209BC is an isolated digital power system supervisor that provides |
| 23 |
a communication interface between a host processor and one Bus Converter Module |
| 24 |
(BCM). The PLI communicates with a system controller via a PMBus compatible |
| 25 |
interface over an isolated UART interface. Through the PLI, the host processor |
| 26 |
can configure, set protection limits, and monitor the BCM. |
| 27 |
|
| 28 |
Sysfs entries |
| 29 |
------------- |
| 30 |
|
| 31 |
======================= ======================================================== |
| 32 |
in1_label "vin2" |
| 33 |
in1_input Input voltage. |
| 34 |
in1_rated_min Minimum rated input voltage. |
| 35 |
in1_rated_max Maximum rated input voltage. |
| 36 |
in1_max Maximum input voltage. |
| 37 |
in1_max_alarm Input voltage high alarm. |
| 38 |
in1_crit Critical input voltage. |
| 39 |
in1_crit_alarm Input voltage critical alarm. |
| 40 |
|
| 41 |
in2_label "vout2" |
| 42 |
in2_input Output voltage. |
| 43 |
in2_rated_min Minimum rated output voltage. |
| 44 |
in2_rated_max Maximum rated output voltage. |
| 45 |
in2_alarm Output voltage alarm |
| 46 |
|
| 47 |
curr1_label "iin2" |
| 48 |
curr1_input Input current. |
| 49 |
curr1_max Maximum input current. |
| 50 |
curr1_max_alarm Maximum input current high alarm. |
| 51 |
curr1_crit Critical input current. |
| 52 |
curr1_crit_alarm Input current critical alarm. |
| 53 |
|
| 54 |
curr2_label "iout2" |
| 55 |
curr2_input Output current. |
| 56 |
curr2_crit Critical output current. |
| 57 |
curr2_crit_alarm Output current critical alarm. |
| 58 |
curr2_max Maximum output current. |
| 59 |
curr2_max_alarm Output current high alarm. |
| 60 |
|
| 61 |
power1_label "pin2" |
| 62 |
power1_input Input power. |
| 63 |
power1_alarm Input power alarm. |
| 64 |
|
| 65 |
power2_label "pout2" |
| 66 |
power2_input Output power. |
| 67 |
power2_rated_max Maximum rated output power. |
| 68 |
|
| 69 |
temp1_input Die temperature. |
| 70 |
temp1_alarm Die temperature alarm. |
| 71 |
temp1_max Maximum die temperature. |
| 72 |
temp1_max_alarm Die temperature high alarm. |
| 73 |
temp1_crit Critical die temperature. |
| 74 |
temp1_crit_alarm Die temperature critical alarm. |
| 75 |
======================= ======================================================== |