| 1 |
Kernel driver lm73 |
| 2 |
================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Texas Instruments LM73 |
| 7 |
|
| 8 |
Prefix: 'lm73' |
| 9 |
|
| 10 |
Addresses scanned: I2C 0x48, 0x49, 0x4a, 0x4c, 0x4d, and 0x4e |
| 11 |
|
| 12 |
Datasheet: Publicly available at the Texas Instruments website |
| 13 |
|
| 14 |
https://www.ti.com/product/lm73 |
| 15 |
|
| 16 |
|
| 17 |
Author: Guillaume Ligneul <[email protected]> |
| 18 |
|
| 19 |
Documentation: Chris Verges <[email protected]> |
| 20 |
|
| 21 |
|
| 22 |
Description |
| 23 |
----------- |
| 24 |
|
| 25 |
The LM73 is a digital temperature sensor. All temperature values are |
| 26 |
given in degrees Celsius. |
| 27 |
|
| 28 |
Measurement Resolution Support |
| 29 |
------------------------------ |
| 30 |
|
| 31 |
The LM73 supports four resolutions, defined in terms of degrees C per |
| 32 |
LSB: 0.25, 0.125, 0.0625, and 0.3125. Changing the resolution mode |
| 33 |
affects the conversion time of the LM73's analog-to-digital converter. |
| 34 |
From userspace, the desired resolution can be specified as a function of |
| 35 |
conversion time via the 'update_interval' sysfs attribute for the |
| 36 |
device. This attribute will normalize ranges of input values to the |
| 37 |
maximum times defined for the resolution in the datasheet. |
| 38 |
|
| 39 |
============= ============= ============ |
| 40 |
Resolution Conv. Time Input Range |
| 41 |
(C/LSB) (msec) (msec) |
| 42 |
============= ============= ============ |
| 43 |
0.25 14 0..14 |
| 44 |
0.125 28 15..28 |
| 45 |
0.0625 56 29..56 |
| 46 |
0.03125 112 57..infinity |
| 47 |
============= ============= ============ |
| 48 |
|
| 49 |
The following examples show how the 'update_interval' attribute can be |
| 50 |
used to change the conversion time:: |
| 51 |
|
| 52 |
$ echo 0 > update_interval |
| 53 |
$ cat update_interval |
| 54 |
14 |
| 55 |
$ cat temp1_input |
| 56 |
24250 |
| 57 |
|
| 58 |
$ echo 22 > update_interval |
| 59 |
$ cat update_interval |
| 60 |
28 |
| 61 |
$ cat temp1_input |
| 62 |
24125 |
| 63 |
|
| 64 |
$ echo 56 > update_interval |
| 65 |
$ cat update_interval |
| 66 |
56 |
| 67 |
$ cat temp1_input |
| 68 |
24062 |
| 69 |
|
| 70 |
$ echo 85 > update_interval |
| 71 |
$ cat update_interval |
| 72 |
112 |
| 73 |
$ cat temp1_input |
| 74 |
24031 |
| 75 |
|
| 76 |
As shown here, the lm73 driver automatically adjusts any user input for |
| 77 |
'update_interval' via a step function. Reading back the |
| 78 |
'update_interval' value after a write operation will confirm the |
| 79 |
conversion time actively in use. |
| 80 |
|
| 81 |
Mathematically, the resolution can be derived from the conversion time |
| 82 |
via the following function: |
| 83 |
|
| 84 |
g(x) = 0.250 * [log(x/14) / log(2)] |
| 85 |
|
| 86 |
where 'x' is the output from 'update_interval' and 'g(x)' is the |
| 87 |
resolution in degrees C per LSB. |
| 88 |
|
| 89 |
Alarm Support |
| 90 |
------------- |
| 91 |
|
| 92 |
The LM73 features a simple over-temperature alarm mechanism. This |
| 93 |
feature is exposed via the sysfs attributes. |
| 94 |
|
| 95 |
The attributes 'temp1_max_alarm' and 'temp1_min_alarm' are flags |
| 96 |
provided by the LM73 that indicate whether the measured temperature has |
| 97 |
passed the 'temp1_max' and 'temp1_min' thresholds, respectively. These |
| 98 |
values _must_ be read to clear the registers on the LM73. |