| 1 |
Kernel driver ina3221 |
| 2 |
===================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Texas Instruments INA3221 |
| 7 |
|
| 8 |
Prefix: 'ina3221' |
| 9 |
|
| 10 |
Addresses: I2C 0x40 - 0x43 |
| 11 |
|
| 12 |
Datasheet: Publicly available at the Texas Instruments website |
| 13 |
|
| 14 |
https://www.ti.com/ |
| 15 |
|
| 16 |
Author: Andrew F. Davis <[email protected]> |
| 17 |
|
| 18 |
Description |
| 19 |
----------- |
| 20 |
|
| 21 |
The Texas Instruments INA3221 monitors voltage, current, and power on the high |
| 22 |
side of up to three D.C. power supplies. The INA3221 monitors both shunt drop |
| 23 |
and supply voltage, with programmable conversion times and averaging, current |
| 24 |
and power are calculated host-side from these. |
| 25 |
|
| 26 |
Sysfs entries |
| 27 |
------------- |
| 28 |
|
| 29 |
======================= ======================================================= |
| 30 |
in[123]_label Voltage channel labels |
| 31 |
in[123]_enable Voltage channel enable controls |
| 32 |
in[123]_input Bus voltage(mV) channels |
| 33 |
curr[123]_input Current(mA) measurement channels |
| 34 |
shunt[123]_resistor Shunt resistance(uOhm) channels |
| 35 |
curr[123]_crit Critical alert current(mA) setting, activates the |
| 36 |
corresponding alarm when the respective current |
| 37 |
is above this value |
| 38 |
curr[123]_crit_alarm Critical alert current limit exceeded |
| 39 |
curr[123]_max Warning alert current(mA) setting, activates the |
| 40 |
corresponding alarm when the respective current |
| 41 |
average is above this value. |
| 42 |
curr[123]_max_alarm Warning alert current limit exceeded |
| 43 |
in[456]_input Shunt voltage(uV) for channels 1, 2, and 3 respectively |
| 44 |
in7_input Sum of shunt voltage(uV) channels |
| 45 |
in7_label Channel label for sum of shunt voltage |
| 46 |
curr4_input Sum of current(mA) measurement channels, |
| 47 |
(only available when all channels use the same resistor |
| 48 |
value for their shunt resistors) |
| 49 |
curr4_crit Critical alert current(mA) setting for sum of current |
| 50 |
measurements, activates the corresponding alarm |
| 51 |
when the respective current is above this value |
| 52 |
(only effective when all channels use the same resistor |
| 53 |
value for their shunt resistors) |
| 54 |
curr4_crit_alarm Critical alert current limit exceeded for sum of |
| 55 |
current measurements. |
| 56 |
samples Number of samples using in the averaging mode. |
| 57 |
|
| 58 |
Supports the list of number of samples: |
| 59 |
|
| 60 |
1, 4, 16, 64, 128, 256, 512, 1024 |
| 61 |
|
| 62 |
update_interval Data conversion time in millisecond, following: |
| 63 |
|
| 64 |
update_interval = C x S x (BC + SC) |
| 65 |
|
| 66 |
* C: number of enabled channels |
| 67 |
* S: number of samples |
| 68 |
* BC: bus-voltage conversion time in millisecond |
| 69 |
* SC: shunt-voltage conversion time in millisecond |
| 70 |
|
| 71 |
Affects both Bus- and Shunt-voltage conversion time. |
| 72 |
Note that setting update_interval to 0ms sets both BC |
| 73 |
and SC to 140 us (minimum conversion time). |
| 74 |
======================= ======================================================= |