| 1 |
Kernel driver inspur-ipsps1 |
| 2 |
=========================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Inspur Power System power supply unit |
| 7 |
|
| 8 |
Author: John Wang <[email protected]> |
| 9 |
|
| 10 |
Description |
| 11 |
----------- |
| 12 |
|
| 13 |
This driver supports Inspur Power System power supplies. This driver |
| 14 |
is a client to the core PMBus driver. |
| 15 |
|
| 16 |
Usage Notes |
| 17 |
----------- |
| 18 |
|
| 19 |
This driver does not auto-detect devices. You will have to instantiate the |
| 20 |
devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for |
| 21 |
details. |
| 22 |
|
| 23 |
Sysfs entries |
| 24 |
------------- |
| 25 |
|
| 26 |
The following attributes are supported: |
| 27 |
|
| 28 |
======================= ====================================================== |
| 29 |
curr1_input Measured input current |
| 30 |
curr1_label "iin" |
| 31 |
curr1_max Maximum current |
| 32 |
curr1_max_alarm Current high alarm |
| 33 |
curr2_input Measured output current in mA. |
| 34 |
curr2_label "iout1" |
| 35 |
curr2_crit Critical maximum current |
| 36 |
curr2_crit_alarm Current critical high alarm |
| 37 |
curr2_max Maximum current |
| 38 |
curr2_max_alarm Current high alarm |
| 39 |
|
| 40 |
fan1_alarm Fan 1 warning. |
| 41 |
fan1_fault Fan 1 fault. |
| 42 |
fan1_input Fan 1 speed in RPM. |
| 43 |
|
| 44 |
in1_alarm Input voltage under-voltage alarm. |
| 45 |
in1_input Measured input voltage in mV. |
| 46 |
in1_label "vin" |
| 47 |
in2_input Measured output voltage in mV. |
| 48 |
in2_label "vout1" |
| 49 |
in2_lcrit Critical minimum output voltage |
| 50 |
in2_lcrit_alarm Output voltage critical low alarm |
| 51 |
in2_max Maximum output voltage |
| 52 |
in2_max_alarm Output voltage high alarm |
| 53 |
in2_min Minimum output voltage |
| 54 |
in2_min_alarm Output voltage low alarm |
| 55 |
|
| 56 |
power1_alarm Input fault or alarm. |
| 57 |
power1_input Measured input power in uW. |
| 58 |
power1_label "pin" |
| 59 |
power1_max Input power limit |
| 60 |
power2_max_alarm Output power high alarm |
| 61 |
power2_max Output power limit |
| 62 |
power2_input Measured output power in uW. |
| 63 |
power2_label "pout" |
| 64 |
|
| 65 |
temp[1-3]_input Measured temperature |
| 66 |
temp[1-2]_max Maximum temperature |
| 67 |
temp[1-3]_max_alarm Temperature high alarm |
| 68 |
|
| 69 |
vendor Manufacturer name |
| 70 |
model Product model |
| 71 |
part_number Product part number |
| 72 |
serial_number Product serial number |
| 73 |
fw_version Firmware version |
| 74 |
hw_version Hardware version |
| 75 |
mode Work mode. Can be set to active or |
| 76 |
standby, when set to standby, PSU will |
| 77 |
automatically switch between standby |
| 78 |
and redundancy mode. |
| 79 |
======================= ====================================================== |