| 1 |
.. SPDX-License-Identifier: GPL-2.0-or-later |
| 2 |
|
| 3 |
Kernel driver ChipCap2 |
| 4 |
====================== |
| 5 |
|
| 6 |
Supported chips: |
| 7 |
|
| 8 |
* Amphenol CC2D23, CC2D23S, CC2D25, CC2D25S, CC2D33, CC2D33S, CC2D35, CC2D35S |
| 9 |
|
| 10 |
Prefix: 'chipcap2' |
| 11 |
|
| 12 |
Addresses scanned: - |
| 13 |
|
| 14 |
Datasheet: https://www.amphenol-sensors.com/en/telaire/humidity/527-humidity-sensors/3095-chipcap-2 |
| 15 |
|
| 16 |
Author: |
| 17 |
|
| 18 |
- Javier Carrasco <[email protected]> |
| 19 |
|
| 20 |
Description |
| 21 |
----------- |
| 22 |
|
| 23 |
This driver implements support for the Amphenol ChipCap 2, a humidity and |
| 24 |
temperature chip family. Temperature is measured in milli degrees celsius, |
| 25 |
relative humidity is expressed as a per cent mille. The measurement ranges |
| 26 |
are the following: |
| 27 |
|
| 28 |
- Relative humidity: 0 to 100000 pcm (14-bit resolution) |
| 29 |
- Temperature: -40000 to +125000 m°C (14-bit resolution) |
| 30 |
|
| 31 |
The device communicates with the I2C protocol and uses the I2C address 0x28 |
| 32 |
by default. |
| 33 |
|
| 34 |
Depending on the hardware configuration, up to two humidity alarms to control |
| 35 |
minimum and maximum values are provided. Their thresholds and hystersis can be |
| 36 |
configured via sysfs. |
| 37 |
|
| 38 |
Thresholds and hysteris must be provided as a per cent mille. These values |
| 39 |
might be truncated to match the 14-bit device resolution (6.1 pcm/LSB) |
| 40 |
|
| 41 |
Known Issues |
| 42 |
------------ |
| 43 |
|
| 44 |
The driver does not support I2C address and command window length modification. |
| 45 |
|
| 46 |
sysfs-Interface |
| 47 |
--------------- |
| 48 |
|
| 49 |
The following list includes the sysfs attributes that the driver always provides, |
| 50 |
their permissions and a short description: |
| 51 |
|
| 52 |
=============================== ======= ======================================== |
| 53 |
Name Perm Description |
| 54 |
=============================== ======= ======================================== |
| 55 |
temp1_input: RO temperature input |
| 56 |
humidity1_input: RO humidity input |
| 57 |
=============================== ======= ======================================== |
| 58 |
|
| 59 |
The following list includes the sysfs attributes that the driver may provide |
| 60 |
depending on the hardware configuration: |
| 61 |
|
| 62 |
=============================== ======= ======================================== |
| 63 |
Name Perm Description |
| 64 |
=============================== ======= ======================================== |
| 65 |
humidity1_min: RW humidity low limit. Measurements under |
| 66 |
this limit trigger a humidity low alarm |
| 67 |
humidity1_max: RW humidity high limit. Measurements above |
| 68 |
this limit trigger a humidity high alarm |
| 69 |
humidity1_min_hyst: RW humidity low hystersis |
| 70 |
humidity1_max_hyst: RW humidity high hystersis |
| 71 |
humidity1_min_alarm: RO humidity low alarm indicator |
| 72 |
humidity1_max_alarm: RO humidity high alarm indicator |
| 73 |
=============================== ======= ======================================== |