| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
Kernel driver bpa-rs600 |
| 4 |
======================= |
| 5 |
|
| 6 |
Supported chips: |
| 7 |
|
| 8 |
* BPA-RS600-120 |
| 9 |
|
| 10 |
Datasheet: Publicly available at the BluTek website |
| 11 |
http://blutekpower.com/wp-content/uploads/2019/01/BPA-RS600-120-07-19-2018.pdf |
| 12 |
|
| 13 |
Authors: |
| 14 |
- Chris Packham <[email protected]> |
| 15 |
|
| 16 |
Description |
| 17 |
----------- |
| 18 |
|
| 19 |
The BPA-RS600 is a compact 600W removable power supply module. |
| 20 |
|
| 21 |
Usage Notes |
| 22 |
----------- |
| 23 |
|
| 24 |
This driver does not probe for PMBus devices. You will have to instantiate |
| 25 |
devices explicitly. |
| 26 |
|
| 27 |
Sysfs attributes |
| 28 |
---------------- |
| 29 |
|
| 30 |
======================= ============================================ |
| 31 |
curr1_label "iin" |
| 32 |
curr1_input Measured input current |
| 33 |
curr1_max Maximum input current |
| 34 |
curr1_max_alarm Input current high alarm |
| 35 |
|
| 36 |
curr2_label "iout1" |
| 37 |
curr2_input Measured output current |
| 38 |
curr2_max Maximum output current |
| 39 |
curr2_max_alarm Output current high alarm |
| 40 |
|
| 41 |
fan1_input Measured fan speed |
| 42 |
fan1_alarm Fan warning |
| 43 |
fan1_fault Fan fault |
| 44 |
|
| 45 |
in1_label "vin" |
| 46 |
in1_input Measured input voltage |
| 47 |
in1_max Maximum input voltage |
| 48 |
in1_max_alarm Input voltage high alarm |
| 49 |
in1_min Minimum input voltage |
| 50 |
in1_min_alarm Input voltage low alarm |
| 51 |
|
| 52 |
in2_label "vout1" |
| 53 |
in2_input Measured output voltage |
| 54 |
in2_max Maximum output voltage |
| 55 |
in2_max_alarm Output voltage high alarm |
| 56 |
in2_min Maximum output voltage |
| 57 |
in2_min_alarm Output voltage low alarm |
| 58 |
|
| 59 |
power1_label "pin" |
| 60 |
power1_input Measured input power |
| 61 |
power1_alarm Input power alarm |
| 62 |
power1_max Maximum input power |
| 63 |
|
| 64 |
power2_label "pout1" |
| 65 |
power2_input Measured output power |
| 66 |
power2_max Maximum output power |
| 67 |
power2_max_alarm Output power high alarm |
| 68 |
|
| 69 |
temp1_input Measured temperature around input connector |
| 70 |
temp1_alarm Temperature alarm |
| 71 |
|
| 72 |
temp2_input Measured temperature around output connector |
| 73 |
temp2_alarm Temperature alarm |
| 74 |
======================= ============================================ |