| 1 |
Kernel driver lm77 |
| 2 |
================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* National Semiconductor LM77 |
| 7 |
|
| 8 |
Prefix: 'lm77' |
| 9 |
|
| 10 |
Addresses scanned: I2C 0x48 - 0x4b |
| 11 |
|
| 12 |
Datasheet: Publicly available at the National Semiconductor website |
| 13 |
|
| 14 |
http://www.national.com/ |
| 15 |
|
| 16 |
|
| 17 |
Author: Andras BALI <[email protected]> |
| 18 |
|
| 19 |
Description |
| 20 |
----------- |
| 21 |
|
| 22 |
The LM77 implements one temperature sensor. The temperature |
| 23 |
sensor incorporates a band-gap type temperature sensor, |
| 24 |
10-bit ADC, and a digital comparator with user-programmable upper |
| 25 |
and lower limit values. |
| 26 |
|
| 27 |
The LM77 implements 3 limits: low (temp1_min), high (temp1_max) and |
| 28 |
critical (temp1_crit.) It also implements an hysteresis mechanism which |
| 29 |
applies to all 3 limits. The relative difference is stored in a single |
| 30 |
register on the chip, which means that the relative difference between |
| 31 |
the limit and its hysteresis is always the same for all 3 limits. |
| 32 |
|
| 33 |
This implementation detail implies the following: |
| 34 |
|
| 35 |
* When setting a limit, its hysteresis will automatically follow, the |
| 36 |
difference staying unchanged. For example, if the old critical limit |
| 37 |
was 80 degrees C, and the hysteresis was 75 degrees C, and you change |
| 38 |
the critical limit to 90 degrees C, then the hysteresis will |
| 39 |
automatically change to 85 degrees C. |
| 40 |
* All 3 hysteresis can't be set independently. We decided to make |
| 41 |
temp1_crit_hyst writable, while temp1_min_hyst and temp1_max_hyst are |
| 42 |
read-only. Setting temp1_crit_hyst writes the difference between |
| 43 |
temp1_crit_hyst and temp1_crit into the chip, and the same relative |
| 44 |
hysteresis applies automatically to the low and high limits. |
| 45 |
* The limits should be set before the hysteresis. |