| 1 |
Kernel driver f71882fg |
| 2 |
====================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Fintek F71808E |
| 7 |
|
| 8 |
Prefix: 'f71808e' |
| 9 |
|
| 10 |
Addresses scanned: none, address read from Super I/O config space |
| 11 |
|
| 12 |
Datasheet: Not public |
| 13 |
|
| 14 |
* Fintek F71808A |
| 15 |
|
| 16 |
Prefix: 'f71808a' |
| 17 |
|
| 18 |
Addresses scanned: none, address read from Super I/O config space |
| 19 |
|
| 20 |
Datasheet: Not public |
| 21 |
|
| 22 |
* Fintek F71858FG |
| 23 |
|
| 24 |
Prefix: 'f71858fg' |
| 25 |
|
| 26 |
Addresses scanned: none, address read from Super I/O config space |
| 27 |
|
| 28 |
Datasheet: Available from the Fintek website |
| 29 |
|
| 30 |
* Fintek F71862FG and F71863FG |
| 31 |
|
| 32 |
Prefix: 'f71862fg' |
| 33 |
|
| 34 |
Addresses scanned: none, address read from Super I/O config space |
| 35 |
|
| 36 |
Datasheet: Available from the Fintek website |
| 37 |
|
| 38 |
* Fintek F71869F and F71869E |
| 39 |
|
| 40 |
Prefix: 'f71869' |
| 41 |
|
| 42 |
Addresses scanned: none, address read from Super I/O config space |
| 43 |
|
| 44 |
Datasheet: Available from the Fintek website |
| 45 |
|
| 46 |
* Fintek F71869A |
| 47 |
|
| 48 |
Prefix: 'f71869a' |
| 49 |
|
| 50 |
Addresses scanned: none, address read from Super I/O config space |
| 51 |
|
| 52 |
Datasheet: Not public |
| 53 |
|
| 54 |
* Fintek F71882FG and F71883FG |
| 55 |
|
| 56 |
Prefix: 'f71882fg' |
| 57 |
|
| 58 |
Addresses scanned: none, address read from Super I/O config space |
| 59 |
|
| 60 |
Datasheet: Available from the Fintek website |
| 61 |
|
| 62 |
* Fintek F71889FG |
| 63 |
|
| 64 |
Prefix: 'f71889fg' |
| 65 |
|
| 66 |
Addresses scanned: none, address read from Super I/O config space |
| 67 |
|
| 68 |
Datasheet: Available from the Fintek website |
| 69 |
|
| 70 |
* Fintek F71889ED |
| 71 |
|
| 72 |
Prefix: 'f71889ed' |
| 73 |
|
| 74 |
Addresses scanned: none, address read from Super I/O config space |
| 75 |
|
| 76 |
Datasheet: Should become available on the Fintek website soon |
| 77 |
|
| 78 |
* Fintek F71889A |
| 79 |
|
| 80 |
Prefix: 'f71889a' |
| 81 |
|
| 82 |
Addresses scanned: none, address read from Super I/O config space |
| 83 |
|
| 84 |
Datasheet: Should become available on the Fintek website soon |
| 85 |
|
| 86 |
* Fintek F8000 |
| 87 |
|
| 88 |
Prefix: 'f8000' |
| 89 |
|
| 90 |
Addresses scanned: none, address read from Super I/O config space |
| 91 |
|
| 92 |
Datasheet: Not public |
| 93 |
|
| 94 |
* Fintek F81801U |
| 95 |
|
| 96 |
Prefix: 'f71889fg' |
| 97 |
|
| 98 |
Addresses scanned: none, address read from Super I/O config space |
| 99 |
|
| 100 |
Datasheet: Not public |
| 101 |
|
| 102 |
Note: |
| 103 |
This is the 64-pin variant of the F71889FG, they have the |
| 104 |
same device ID and are fully compatible as far as hardware |
| 105 |
monitoring is concerned. |
| 106 |
|
| 107 |
* Fintek F81865F |
| 108 |
|
| 109 |
Prefix: 'f81865f' |
| 110 |
|
| 111 |
Addresses scanned: none, address read from Super I/O config space |
| 112 |
|
| 113 |
Datasheet: Available from the Fintek website |
| 114 |
|
| 115 |
Author: Hans de Goede <[email protected]> |
| 116 |
|
| 117 |
|
| 118 |
Description |
| 119 |
----------- |
| 120 |
|
| 121 |
Fintek F718xx/F8000 Super I/O chips include complete hardware monitoring |
| 122 |
capabilities. They can monitor up to 9 voltages, 4 fans and 3 temperature |
| 123 |
sensors. |
| 124 |
|
| 125 |
These chips also have fan controlling features, using either DC or PWM, in |
| 126 |
three different modes (one manual, two automatic). |
| 127 |
|
| 128 |
The driver assumes that no more than one chip is present, which seems |
| 129 |
reasonable. |
| 130 |
|
| 131 |
|
| 132 |
Monitoring |
| 133 |
---------- |
| 134 |
|
| 135 |
The Voltage, Fan and Temperature Monitoring uses the standard sysfs |
| 136 |
interface as documented in sysfs-interface, without any exceptions. |
| 137 |
|
| 138 |
|
| 139 |
Fan Control |
| 140 |
----------- |
| 141 |
|
| 142 |
Both PWM (pulse-width modulation) and DC fan speed control methods are |
| 143 |
supported. The right one to use depends on external circuitry on the |
| 144 |
motherboard, so the driver assumes that the BIOS set the method |
| 145 |
properly. |
| 146 |
|
| 147 |
Note that the lowest numbered temperature zone trip point corresponds to |
| 148 |
the border between the highest and one but highest temperature zones, and |
| 149 |
vica versa. So the temperature zone trip points 1-4 (or 1-2) go from high temp |
| 150 |
to low temp! This is how things are implemented in the IC, and the driver |
| 151 |
mimics this. |
| 152 |
|
| 153 |
There are 2 modes to specify the speed of the fan, PWM duty cycle (or DC |
| 154 |
voltage) mode, where 0-100% duty cycle (0-100% of 12V) is specified. And RPM |
| 155 |
mode where the actual RPM of the fan (as measured) is controlled and the speed |
| 156 |
gets specified as 0-100% of the fan#_full_speed file. |
| 157 |
|
| 158 |
Since both modes work in a 0-100% (mapped to 0-255) scale, there isn't a |
| 159 |
whole lot of a difference when modifying fan control settings. The only |
| 160 |
important difference is that in RPM mode the 0-100% controls the fan speed |
| 161 |
between 0-100% of fan#_full_speed. It is assumed that if the BIOS programs |
| 162 |
RPM mode, it will also set fan#_full_speed properly, if it does not then |
| 163 |
fan control will not work properly, unless you set a sane fan#_full_speed |
| 164 |
value yourself. |
| 165 |
|
| 166 |
Switching between these modes requires re-initializing a whole bunch of |
| 167 |
registers, so the mode which the BIOS has set is kept. The mode is |
| 168 |
printed when loading the driver. |
| 169 |
|
| 170 |
Three different fan control modes are supported; the mode number is written |
| 171 |
to the pwm#_enable file. Note that not all modes are supported on all |
| 172 |
chips, and some modes may only be available in RPM / PWM mode. |
| 173 |
Writing an unsupported mode will result in an invalid parameter error. |
| 174 |
|
| 175 |
* 1: Manual mode |
| 176 |
You ask for a specific PWM duty cycle / DC voltage or a specific % of |
| 177 |
fan#_full_speed by writing to the pwm# file. This mode is only |
| 178 |
available on the F71858FG / F8000 if the fan channel is in RPM mode. |
| 179 |
|
| 180 |
* 2: Normal auto mode |
| 181 |
You can define a number of temperature/fan speed trip points that specify |
| 182 |
the percentage at which the fan should run at each temperature, and which |
| 183 |
temperature sensor a fan should follow, using the standard sysfs interface. |
| 184 |
The number and type of trip points are chip dependent - see the available |
| 185 |
files in sysfs. |
| 186 |
Fan/PWM channel 3 of the F8000 is always in this mode! |
| 187 |
|
| 188 |
* 3: Thermostat mode (Only available on the F8000 when in duty cycle mode) |
| 189 |
The fan speed is regulated to keep the temp the fan is mapped to between |
| 190 |
temp#_auto_point2_temp and temp#_auto_point3_temp. |
| 191 |
|
| 192 |
All of the automatic modes require that pwm1 corresponds to fan1, pwm2 to |
| 193 |
fan2 and pwm3 to fan3. |