| 1 |
Kernel driver max16064 |
| 2 |
====================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Maxim MAX16064 |
| 7 |
|
| 8 |
Prefix: 'max16064' |
| 9 |
|
| 10 |
Addresses scanned: - |
| 11 |
|
| 12 |
Datasheet: https://www.digikey.com/en/htmldatasheets/production/701833/0/0/1/max16064 |
| 13 |
|
| 14 |
Author: Guenter Roeck <[email protected]> |
| 15 |
|
| 16 |
|
| 17 |
Description |
| 18 |
----------- |
| 19 |
|
| 20 |
This driver supports hardware monitoring for Maxim MAX16064 Quad Power-Supply |
| 21 |
Controller with Active-Voltage Output Control and PMBus Interface. |
| 22 |
|
| 23 |
The driver is a client driver to the core PMBus driver. |
| 24 |
Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers. |
| 25 |
|
| 26 |
|
| 27 |
Usage Notes |
| 28 |
----------- |
| 29 |
|
| 30 |
This driver does not auto-detect devices. You will have to instantiate the |
| 31 |
devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for |
| 32 |
details. |
| 33 |
|
| 34 |
|
| 35 |
Platform data support |
| 36 |
--------------------- |
| 37 |
|
| 38 |
The driver supports standard PMBus driver platform data. |
| 39 |
|
| 40 |
|
| 41 |
Sysfs entries |
| 42 |
------------- |
| 43 |
|
| 44 |
The following attributes are supported. Limits are read-write; all other |
| 45 |
attributes are read-only. |
| 46 |
|
| 47 |
======================= ======================================================== |
| 48 |
in[1-4]_label "vout[1-4]" |
| 49 |
in[1-4]_input Measured voltage. From READ_VOUT register. |
| 50 |
in[1-4]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register. |
| 51 |
in[1-4]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. |
| 52 |
in[1-4]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register. |
| 53 |
in[1-4]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT |
| 54 |
register. |
| 55 |
in[1-4]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. |
| 56 |
in[1-4]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. |
| 57 |
in[1-4]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT |
| 58 |
status. |
| 59 |
in[1-4]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT |
| 60 |
status. |
| 61 |
in[1-4]_highest Historical maximum voltage. |
| 62 |
in[1-4]_reset_history Write any value to reset history. |
| 63 |
|
| 64 |
temp1_input Measured temperature. From READ_TEMPERATURE_1 register. |
| 65 |
temp1_max Maximum temperature. From OT_WARN_LIMIT register. |
| 66 |
temp1_crit Critical high temperature. From OT_FAULT_LIMIT register. |
| 67 |
temp1_max_alarm Chip temperature high alarm. Set by comparing |
| 68 |
READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING |
| 69 |
status is set. |
| 70 |
temp1_crit_alarm Chip temperature critical high alarm. Set by comparing |
| 71 |
READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT |
| 72 |
status is set. |
| 73 |
temp1_highest Historical maximum temperature. |
| 74 |
temp1_reset_history Write any value to reset history. |
| 75 |
======================= ======================================================== |