| 1 |
.. SPDX-License-Identifier: GPL-2.0-or-later |
| 2 |
|
| 3 |
Kernel driver nzxt-kraken3 |
| 4 |
========================== |
| 5 |
|
| 6 |
Supported devices: |
| 7 |
|
| 8 |
* NZXT Kraken X53 |
| 9 |
* NZXT Kraken X63 |
| 10 |
* NZXT Kraken X73 |
| 11 |
* NZXT Kraken Z53 |
| 12 |
* NZXT Kraken Z63 |
| 13 |
* NZXT Kraken Z73 |
| 14 |
* NZXT Kraken 2023 |
| 15 |
* NZXT Kraken 2023 Elite |
| 16 |
|
| 17 |
Author: Jonas Malaco, Aleksa Savic |
| 18 |
|
| 19 |
Description |
| 20 |
----------- |
| 21 |
|
| 22 |
This driver enables hardware monitoring support for NZXT Kraken X53/X63/X73, |
| 23 |
Z53/Z63/Z73 and Kraken 2023 (standard and Elite) all-in-one CPU liquid coolers. |
| 24 |
All models expose liquid temperature and pump speed (in RPM), as well as PWM |
| 25 |
control (either as a fixed value or through a temp-PWM curve). The Z-series and |
| 26 |
Kraken 2023 models additionally expose the speed and duty of an optionally connected |
| 27 |
fan, with the same PWM control capabilities. |
| 28 |
|
| 29 |
Pump and fan duty control mode can be set through pwm[1-2]_enable, where 1 is |
| 30 |
for the manual control mode and 2 is for the liquid temp to PWM curve mode. |
| 31 |
Writing a 0 disables control of the channel through the driver after setting its |
| 32 |
duty to 100%. |
| 33 |
|
| 34 |
The temperature of the curves relates to the fixed [20-59] range, correlating to |
| 35 |
the detected liquid temperature. Only PWM values (ranging from 0-255) can be set. |
| 36 |
If in curve mode, setting point values should be done in moderation - the devices |
| 37 |
require complete curves to be sent for each change; they can lock up or discard |
| 38 |
the changes if they are too numerous at once. Suggestion is to set them while |
| 39 |
in an another mode, and then apply them by switching to curve. |
| 40 |
|
| 41 |
The devices can report if they are faulty. The driver supports that situation |
| 42 |
and will issue a warning. This can also happen when the USB cable is connected, |
| 43 |
but SATA power is not. |
| 44 |
|
| 45 |
The addressable RGB LEDs and LCD screen (only on Z-series and Kraken 2023 models) |
| 46 |
are not supported in this driver, but can be controlled through existing userspace |
| 47 |
tools, such as `liquidctl`_. |
| 48 |
|
| 49 |
.. _liquidctl: https://github.com/liquidctl/liquidctl |
| 50 |
|
| 51 |
Usage Notes |
| 52 |
----------- |
| 53 |
|
| 54 |
As these are USB HIDs, the driver can be loaded automatically by the kernel and |
| 55 |
supports hot swapping. |
| 56 |
|
| 57 |
Possible pwm_enable values are: |
| 58 |
|
| 59 |
====== ========================================================================== |
| 60 |
0 Set fan to 100% |
| 61 |
1 Direct PWM mode (applies value in corresponding PWM entry) |
| 62 |
2 Curve control mode (applies the temp-PWM duty curve based on coolant temp) |
| 63 |
====== ========================================================================== |
| 64 |
|
| 65 |
Sysfs entries |
| 66 |
------------- |
| 67 |
|
| 68 |
============================== ================================================================ |
| 69 |
fan1_input Pump speed (in rpm) |
| 70 |
fan2_input Fan speed (in rpm) |
| 71 |
temp1_input Coolant temperature (in millidegrees Celsius) |
| 72 |
pwm1 Pump duty (value between 0-255) |
| 73 |
pwm1_enable Pump duty control mode (0: disabled, 1: manual, 2: curve) |
| 74 |
pwm2 Fan duty (value between 0-255) |
| 75 |
pwm2_enable Fan duty control mode (0: disabled, 1: manual, 2: curve) |
| 76 |
temp[1-2]_auto_point[1-40]_pwm Temp-PWM duty curves (for pump and fan), related to coolant temp |
| 77 |
============================== ================================================================ |