1 .. SPDX-License-Identifier: GPL-2.0
2
3 Kernel driver kbatt
4 ===================
5
6 Supported chips:
7
8 * KEBA battery monitoring controller (IP core in FPGA)
9
10 Prefix: 'kbatt'
11
12 Authors:
13
14 Gerhard Engleder <[email protected]>
15 Petar Bojanic <[email protected]>
16
17 Description
18 -----------
19
20 The KEBA battery monitoring controller is an IP core for FPGAs, which
21 monitors the health of a coin cell battery. The coin cell battery is
22 typically used to supply the RTC during power off to keep the current
23 time. E.g., the CP500 FPGA includes this IP core to monitor the coin cell
24 battery of PLCs and the corresponding cp500 driver creates an auxiliary
25 device for the kbatt driver.
26
27 This driver provides information about the coin cell battery health to
28 user space. Actually the user space shall be informed that the coin cell
29 battery is nearly empty and needs to be replaced.
30
31 The coin cell battery must be tested actively to get to know if its nearly
32 empty or not. Therefore, a load is put on the coin cell battery and the
33 resulting voltage is evaluated. This evaluation is done by some hard wired
34 analog logic, which compares the voltage to a defined limit. If the
35 voltage is above the limit, then the coin cell battery is assumed to be
36 ok. If the voltage is below the limit, then the coin cell battery is
37 nearly empty (or broken, removed, ...) and shall be replaced by a new one.
38 The KEBA battery monitoring controller allows to start the test of the
39 coin cell battery and to get the result if the voltage is above or below
40 the limit. The actual voltage is not available. Only the information if
41 the voltage is below a limit is available.
42
43 The test load, which is put on the coin cell battery for the health check,
44 is similar to the load during power off. Therefore, the lifetime of the
45 coin cell battery is reduced directly by the duration of each test. To
46 limit the negative impact to the lifetime the test is limited to at most
47 once every 10 seconds. The test load is put on the coin cell battery for
48 100ms. Thus, in worst case the coin cell battery lifetime is reduced by
49 1% of the uptime or 3.65 days per year. As the coin cell battery lasts
50 multiple years, this lifetime reduction negligible.
51
52 This driver only provides a single alarm attribute, which is raised when
53 the coin cell battery is nearly empty.
54
55 ====================== ==== ===================================================
56 Attribute R/W Contents
57 ====================== ==== ===================================================
58 in0_min_alarm R voltage of coin cell battery under load is below
59 limit
60 ====================== ==== ===================================================