| 1 |
Kernel driver asb100 |
| 2 |
==================== |
| 3 |
|
| 4 |
Supported Chips: |
| 5 |
|
| 6 |
* Asus ASB100 and ASB100-A "Bach" |
| 7 |
|
| 8 |
Prefix: 'asb100' |
| 9 |
|
| 10 |
Addresses scanned: I2C 0x2d |
| 11 |
|
| 12 |
Datasheet: none released |
| 13 |
|
| 14 |
Author: Mark M. Hoffman <[email protected]> |
| 15 |
|
| 16 |
Description |
| 17 |
----------- |
| 18 |
|
| 19 |
This driver implements support for the Asus ASB100 and ASB100-A "Bach". |
| 20 |
These are custom ASICs available only on Asus mainboards. Asus refuses to |
| 21 |
supply a datasheet for these chips. Thanks go to many people who helped |
| 22 |
investigate their hardware, including: |
| 23 |
|
| 24 |
Vitaly V. Bursov |
| 25 |
Alexander van Kaam (author of MBM for Windows) |
| 26 |
Bertrik Sikken |
| 27 |
|
| 28 |
The ASB100 implements seven voltage sensors, three fan rotation speed |
| 29 |
sensors, four temperature sensors, VID lines and alarms. In addition to |
| 30 |
these, the ASB100-A also implements a single PWM controller for fans 2 and |
| 31 |
3 (i.e. one setting controls both.) If you have a plain ASB100, the PWM |
| 32 |
controller will simply not work (or maybe it will for you... it doesn't for |
| 33 |
me). |
| 34 |
|
| 35 |
Temperatures are measured and reported in degrees Celsius. |
| 36 |
|
| 37 |
Fan speeds are reported in RPM (rotations per minute). An alarm is |
| 38 |
triggered if the rotation speed has dropped below a programmable limit. |
| 39 |
|
| 40 |
Voltage sensors (also known as IN sensors) report values in volts. |
| 41 |
|
| 42 |
The VID lines encode the core voltage value: the voltage level your |
| 43 |
processor should work with. This is hardcoded by the mainboard and/or |
| 44 |
processor itself. It is a value in volts. |
| 45 |
|
| 46 |
Alarms: (TODO question marks indicate may or may not work) |
| 47 |
|
| 48 |
- 0x0001 => in0 (?) |
| 49 |
- 0x0002 => in1 (?) |
| 50 |
- 0x0004 => in2 |
| 51 |
- 0x0008 => in3 |
| 52 |
- 0x0010 => temp1 [1]_ |
| 53 |
- 0x0020 => temp2 |
| 54 |
- 0x0040 => fan1 |
| 55 |
- 0x0080 => fan2 |
| 56 |
- 0x0100 => in4 |
| 57 |
- 0x0200 => in5 (?) [2]_ |
| 58 |
- 0x0400 => in6 (?) [2]_ |
| 59 |
- 0x0800 => fan3 |
| 60 |
- 0x1000 => chassis switch |
| 61 |
- 0x2000 => temp3 |
| 62 |
|
| 63 |
.. [1] This alarm will only trigger if the hysteresis value is 127C. |
| 64 |
I.e. it behaves the same as w83781d. |
| 65 |
|
| 66 |
.. [2] The min and max registers for these values appear to |
| 67 |
be read-only or otherwise stuck at 0x00. |
| 68 |
|
| 69 |
TODO: |
| 70 |
* Experiment with fan divisors > 8. |
| 71 |
* Experiment with temp. sensor types. |
| 72 |
* Are there really 13 voltage inputs? Probably not... |
| 73 |