| 1 |
Kernel Driver IBMPOWERNV |
| 2 |
======================== |
| 3 |
|
| 4 |
Supported systems: |
| 5 |
|
| 6 |
* Any recent IBM P servers based on POWERNV platform |
| 7 |
|
| 8 |
Author: Neelesh Gupta |
| 9 |
|
| 10 |
Description |
| 11 |
----------- |
| 12 |
|
| 13 |
This driver implements reading the platform sensors data like temperature/fan/ |
| 14 |
voltage/power for 'POWERNV' platform. |
| 15 |
|
| 16 |
The driver uses the platform device infrastructure. It probes the device tree |
| 17 |
for sensor devices during the __init phase and registers them with the 'hwmon'. |
| 18 |
'hwmon' populates the 'sysfs' tree having attribute files, each for a given |
| 19 |
sensor type and its attribute data. |
| 20 |
|
| 21 |
All the nodes in the DT appear under "/ibm,opal/sensors" and each valid node in |
| 22 |
the DT maps to an attribute file in 'sysfs'. The node exports unique 'sensor-id' |
| 23 |
which the driver uses to make an OPAL call to the firmware. |
| 24 |
|
| 25 |
Usage notes |
| 26 |
----------- |
| 27 |
The driver is built statically with the kernel by enabling the config |
| 28 |
CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'. |
| 29 |
|
| 30 |
Sysfs attributes |
| 31 |
---------------- |
| 32 |
|
| 33 |
======================= ======================================================= |
| 34 |
fanX_input Measured RPM value. |
| 35 |
fanX_min Threshold RPM for alert generation. |
| 36 |
fanX_fault - 0: No fail condition |
| 37 |
- 1: Failing fan |
| 38 |
|
| 39 |
tempX_input Measured ambient temperature. |
| 40 |
tempX_max Threshold ambient temperature for alert generation. |
| 41 |
tempX_highest Historical maximum temperature |
| 42 |
tempX_lowest Historical minimum temperature |
| 43 |
tempX_enable Enable/disable all temperature sensors belonging to the |
| 44 |
sub-group. In POWER9, this attribute corresponds to |
| 45 |
each OCC. Using this attribute each OCC can be asked to |
| 46 |
disable/enable all of its temperature sensors. |
| 47 |
|
| 48 |
- 1: Enable |
| 49 |
- 0: Disable |
| 50 |
|
| 51 |
inX_input Measured power supply voltage (millivolt) |
| 52 |
inX_fault - 0: No fail condition. |
| 53 |
- 1: Failing power supply. |
| 54 |
inX_highest Historical maximum voltage |
| 55 |
inX_lowest Historical minimum voltage |
| 56 |
inX_enable Enable/disable all voltage sensors belonging to the |
| 57 |
sub-group. In POWER9, this attribute corresponds to |
| 58 |
each OCC. Using this attribute each OCC can be asked to |
| 59 |
disable/enable all of its voltage sensors. |
| 60 |
|
| 61 |
- 1: Enable |
| 62 |
- 0: Disable |
| 63 |
|
| 64 |
powerX_input Power consumption (microWatt) |
| 65 |
powerX_input_highest Historical maximum power |
| 66 |
powerX_input_lowest Historical minimum power |
| 67 |
powerX_enable Enable/disable all power sensors belonging to the |
| 68 |
sub-group. In POWER9, this attribute corresponds to |
| 69 |
each OCC. Using this attribute each OCC can be asked to |
| 70 |
disable/enable all of its power sensors. |
| 71 |
|
| 72 |
- 1: Enable |
| 73 |
- 0: Disable |
| 74 |
|
| 75 |
currX_input Measured current (milliampere) |
| 76 |
currX_highest Historical maximum current |
| 77 |
currX_lowest Historical minimum current |
| 78 |
currX_enable Enable/disable all current sensors belonging to the |
| 79 |
sub-group. In POWER9, this attribute corresponds to |
| 80 |
each OCC. Using this attribute each OCC can be asked to |
| 81 |
disable/enable all of its current sensors. |
| 82 |
|
| 83 |
- 1: Enable |
| 84 |
- 0: Disable |
| 85 |
|
| 86 |
energyX_input Cumulative energy (microJoule) |
| 87 |
======================= ======================================================= |