Kernel driver max31827 |
| 4 |
====================== |
| 5 |
|
| 6 |
Supported chips: |
| 7 |
|
| 8 |
* Maxim MAX31827 |
| 9 |
|
| 10 |
Prefix: 'max31827' |
| 11 |
|
| 12 |
Addresses scanned: I2C 0x40 - 0x5f |
| 13 |
|
| 14 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/MAX31827-MAX31829.pdf |
| 15 |
|
| 16 |
* Maxim MAX31828 |
| 17 |
|
| 18 |
Prefix: 'max31828' |
| 19 |
|
| 20 |
Addresses scanned: I2C 0x40 - 0x5f |
| 21 |
|
| 22 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/MAX31827-MAX31829.pdf |
| 23 |
|
| 24 |
* Maxim MAX31829 |
| 25 |
|
| 26 |
Prefix: 'max31829' |
| 27 |
|
| 28 |
Addresses scanned: I2C 0x40 - 0x5f |
| 29 |
|
| 30 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/MAX31827-MAX31829.pdf |
| 31 |
|
| 32 |
|
| 33 |
Authors: |
| 34 |
- Daniel Matyas <[email protected]> |
| 35 |
|
| 36 |
Description |
| 37 |
----------- |
| 38 |
|
| 39 |
The chips supported by this driver are quite similar. The only difference |
| 40 |
between them is found in the default power-on behaviour of the chips. While the |
| 41 |
MAX31827's fault queue is set to 1, the other two chip's fault queue is set to |
| 42 |
4. Besides this, the MAX31829's alarm active state is high, while the other two |
| 43 |
chip's alarms are active on low. It is important to note that the chips can be |
| 44 |
configured to operate in the same manner with 1 write operation to the |
| 45 |
configuration register. From here on, we will refer to all these chips as |
| 46 |
MAX31827. |
| 47 |
|
| 48 |
MAX31827 implements a temperature sensor with a 6 WLP packaging scheme. This |
| 49 |
sensor measures the temperature of the chip itself. |
| 50 |
|
| 51 |
MAX31827 has low and over temperature alarms with an effective value and a |
| 52 |
hysteresis value: -40 and -30 degrees for under temperature alarm and +100 and |
| 53 |
+90 degrees for over temperature alarm. |
| 54 |
|
| 55 |
The alarm can be configured in comparator and interrupt mode from the |
| 56 |
devicetree. In Comparator mode, the OT/UT status bits have a value of 1 when the |
| 57 |
temperature rises above the TH value or falls below TL, which is also subject to |
| 58 |
the Fault Queue selection. OT status returns to 0 when the temperature drops |
| 59 |
below the TH_HYST value or when shutdown mode is entered. Similarly, UT status |
| 60 |
returns to 0 when the temperature rises above TL_HYST value or when shutdown |
| 61 |
mode is entered. |
| 62 |
|
| 63 |
In interrupt mode exceeding TH also sets OT status to 1, which remains set until |
| 64 |
a read operation is performed on the configuration/status register (max or min |
| 65 |
attribute); at this point, it returns to 0. Once OT status is set to 1 from |
| 66 |
exceeding TH and reset, it is set to 1 again only when the temperature drops |
| 67 |
below TH_HYST. The output remains asserted until it is reset by a read. It is |
| 68 |
set again if the temperature rises above TH, and so on. The same logic applies |
| 69 |
to the operation of the UT status bit. |
| 70 |
|
| 71 |
Putting the MAX31827 into shutdown mode also resets the OT/UT status bits. Note |
| 72 |
that if the mode is changed while OT/UT status bits are set, an OT/UT status |
| 73 |
reset may be required before it begins to behave normally. To prevent this, |
| 74 |
it is recommended to perform a read of the configuration/status register to |
| 75 |
clear the status bits before changing the operating mode. |
| 76 |
|
| 77 |
The conversions can be manual with the one-shot functionality and automatic with |
| 78 |
a set frequency. When powered on, the chip measures temperatures with 1 conv/s. |
| 79 |
The conversion rate can be modified with update_interval attribute of the chip. |
| 80 |
Conversion/second = 1/update_interval. Thus, the available options according to |
| 81 |
the data sheet are: |
| 82 |
|
| 83 |
- 64000 (ms) = 1 conv/64 sec |
| 84 |
- 32000 (ms) = 1 conv/32 sec |
| 85 |
- 16000 (ms) = 1 conv/16 sec |
| 86 |
- 4000 (ms) = 1 conv/4 sec |
| 87 |
- 1000 (ms) = 1 conv/sec (default) |
| 88 |
- 250 (ms) = 4 conv/sec |
| 89 |
- 125 (ms) = 8 conv/sec |
| 90 |
|
| 91 |
Enabling the device when it is already enabled has the side effect of setting |
| 92 |
the conversion frequency to 1 conv/s. The conversion time varies depending on |
| 93 |
the resolution. |
| 94 |
|
| 95 |
The conversion time doubles with every bit of increased resolution. The |
| 96 |
available resolutions are: |
| 97 |
|
| 98 |
- 8 bit -> 8.75 ms conversion time |
| 99 |
- 9 bit -> 17.5 ms conversion time |
| 100 |
- 10 bit -> 35 ms conversion time |
| 101 |
- 12 bit (default) -> 140 ms conversion time |
| 102 |
|
| 103 |
There is a temp1_resolution attribute which indicates the unit change in the |
| 104 |
input temperature in milli-degrees C. |
| 105 |
|
| 106 |
- 1000 mC -> 8 bit |
| 107 |
- 500 mC -> 9 bit |
| 108 |
- 250 mC -> 10 bit |
| 109 |
- 62 mC -> 12 bit (default) - actually this is 62.5, but the fil returns 62 |
| 110 |
|
| 111 |
When chip is in shutdown mode and a read operation is requested, one-shot is |
| 112 |
triggered, the device waits for <conversion time> ms, and only after that is |
| 113 |
the temperature value register read. Note that the conversion times are rounded |
| 114 |
up to the nearest possible integer. |
| 115 |
|
| 116 |
The LSB of the temperature values is 0.0625 degrees Celsius, but the values of |
| 117 |
the temperatures are displayed in milli-degrees. This means, that some data is |
| 118 |
lost. The step between 2 consecutive values is 62 or 63. This effect can be seen |
| 119 |
in the writing of alarm values too. For positive numbers the user-input value |
| 120 |
will always be rounded down to the nearest possible value, for negative numbers |
| 121 |
the user-input will always be rounded up to the nearest possible value. |
| 122 |
|
| 123 |
Bus timeout resets the I2C-compatible interface when SCL is low for more than |
| 124 |
30ms (nominal). |
| 125 |
|
| 126 |
Alarm polarity determines if the active state of the alarm is low or high. The |
| 127 |
behavior for both settings is dependent on the Fault Queue setting. The ALARM |
| 128 |
pin is an open-drain output and requires a pullup resistor to operate. |
| 129 |
|
| 130 |
The Fault Queue bits select how many consecutive temperature faults must occur |
| 131 |
before overtemperature or undertemperature faults are indicated in the |
| 132 |
corresponding status bits. |
| 133 |
|
| 134 |
PEC Support |
| 135 |
----------- |
| 136 |
|
| 137 |
When reading a register value, the PEC byte is computed and sent by the chip. |
| 138 |
|
| 139 |
PEC on word data transaction represents a significant increase in bandwidth |
| 140 |
usage (+33% for both write and reads) in normal conditions. |
| 141 |
|
| 142 |
Since this operation implies there will be an extra delay to each |
| 143 |
transaction, PEC can be disabled or enabled through sysfs. |
| 144 |
Just write 1 to the "pec" file for enabling PEC and 0 for disabling it. |