| 1 |
Kernel driver ds1621 |
| 2 |
==================== |
| 3 |
|
| 4 |
Supported chips: |
| 5 |
|
| 6 |
* Dallas Semiconductor / Maxim Integrated DS1621 |
| 7 |
|
| 8 |
Prefix: 'ds1621' |
| 9 |
|
| 10 |
Addresses scanned: none |
| 11 |
|
| 12 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/DS1621.pdf |
| 13 |
|
| 14 |
* Dallas Semiconductor DS1625 |
| 15 |
|
| 16 |
Prefix: 'ds1625' |
| 17 |
|
| 18 |
Addresses scanned: none |
| 19 |
|
| 20 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/DS1620.pdf |
| 21 |
|
| 22 |
* Maxim Integrated DS1631 |
| 23 |
|
| 24 |
Prefix: 'ds1631' |
| 25 |
|
| 26 |
Addresses scanned: none |
| 27 |
|
| 28 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/DS1631-DS1731.pdf |
| 29 |
|
| 30 |
* Maxim Integrated DS1721 |
| 31 |
|
| 32 |
Prefix: 'ds1721' |
| 33 |
|
| 34 |
Addresses scanned: none |
| 35 |
|
| 36 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/DS1721.pdf |
| 37 |
|
| 38 |
* Maxim Integrated DS1731 |
| 39 |
|
| 40 |
Prefix: 'ds1731' |
| 41 |
|
| 42 |
Addresses scanned: none |
| 43 |
|
| 44 |
Datasheet: https://www.analog.com/media/en/technical-documentation/data-sheets/DS1631-DS1731.pdf |
| 45 |
|
| 46 |
Authors: |
| 47 |
- Christian W. Zuckschwerdt <[email protected]> |
| 48 |
- valuable contributions by Jan M. Sendler <[email protected]> |
| 49 |
- ported to 2.6 by Aurelien Jarno <[email protected]> |
| 50 |
with the help of Jean Delvare <[email protected]> |
| 51 |
|
| 52 |
Module Parameters |
| 53 |
------------------ |
| 54 |
|
| 55 |
* polarity int |
| 56 |
Output's polarity: |
| 57 |
|
| 58 |
* 0 = active high, |
| 59 |
* 1 = active low |
| 60 |
|
| 61 |
Description |
| 62 |
----------- |
| 63 |
|
| 64 |
The DS1621 is a (one instance) digital thermometer and thermostat. It has |
| 65 |
both high and low temperature limits which can be user defined (i.e. |
| 66 |
programmed into non-volatile on-chip registers). Temperature range is -55 |
| 67 |
degree Celsius to +125 in 0.5 increments. You may convert this into a |
| 68 |
Fahrenheit range of -67 to +257 degrees with 0.9 steps. If polarity |
| 69 |
parameter is not provided, original value is used. |
| 70 |
|
| 71 |
As for the thermostat, behavior can also be programmed using the polarity |
| 72 |
toggle. On the one hand ("heater"), the thermostat output of the chip, |
| 73 |
Tout, will trigger when the low limit temperature is met or underrun and |
| 74 |
stays high until the high limit is met or exceeded. On the other hand |
| 75 |
("cooler"), vice versa. That way "heater" equals "active low", whereas |
| 76 |
"conditioner" equals "active high". Please note that the DS1621 data sheet |
| 77 |
is somewhat misleading in this point since setting the polarity bit does |
| 78 |
not simply invert Tout. |
| 79 |
|
| 80 |
A second thing is that, during extensive testing, Tout showed a tolerance |
| 81 |
of up to +/- 0.5 degrees even when compared against precise temperature |
| 82 |
readings. Be sure to have a high vs. low temperature limit gap of al least |
| 83 |
1.0 degree Celsius to avoid Tout "bouncing", though! |
| 84 |
|
| 85 |
The alarm bits are set when the high or low limits are met or exceeded and |
| 86 |
are reset by the module as soon as the respective temperature ranges are |
| 87 |
left. |
| 88 |
|
| 89 |
The alarm registers are in no way suitable to find out about the actual |
| 90 |
status of Tout. They will only tell you about its history, whether or not |
| 91 |
any of the limits have ever been met or exceeded since last power-up or |
| 92 |
reset. Be aware: When testing, it showed that the status of Tout can change |
| 93 |
with neither of the alarms set. |
| 94 |
|
| 95 |
Since there is no version or vendor identification register, there is |
| 96 |
no unique identification for these devices. Therefore, explicit device |
| 97 |
instantiation is required for correct device identification and functionality |
| 98 |
(one device per address in this address range: 0x48..0x4f). |
| 99 |
|
| 100 |
The DS1625 is pin compatible and functionally equivalent with the DS1621, |
| 101 |
but the DS1621 is meant to replace it. The DS1631, DS1721, and DS1731 are |
| 102 |
also pin compatible with the DS1621 and provide multi-resolution support. |
| 103 |
|
| 104 |
Additionally, the DS1721 data sheet says the temperature flags (THF and TLF) |
| 105 |
are used internally, however, these flags do get set and cleared as the actual |
| 106 |
temperature crosses the min or max settings (which by default are set to 75 |
| 107 |
and 80 degrees respectively). |
| 108 |
|
| 109 |
Temperature Conversion |
| 110 |
---------------------- |
| 111 |
|
| 112 |
- DS1621 - 750ms (older devices may take up to 1000ms) |
| 113 |
- DS1625 - 500ms |
| 114 |
- DS1631 - 93ms..750ms for 9..12 bits resolution, respectively. |
| 115 |
- DS1721 - 93ms..750ms for 9..12 bits resolution, respectively. |
| 116 |
- DS1731 - 93ms..750ms for 9..12 bits resolution, respectively. |
| 117 |
|
| 118 |
Note: |
| 119 |
On the DS1621, internal access to non-volatile registers may last for 10ms |
| 120 |
or less (unverified on the other devices). |
| 121 |
|
| 122 |
Temperature Accuracy |
| 123 |
-------------------- |
| 124 |
|
| 125 |
- DS1621: +/- 0.5 degree Celsius (from 0 to +70 degrees) |
| 126 |
- DS1625: +/- 0.5 degree Celsius (from 0 to +70 degrees) |
| 127 |
- DS1631: +/- 0.5 degree Celsius (from 0 to +70 degrees) |
| 128 |
- DS1721: +/- 1.0 degree Celsius (from -10 to +85 degrees) |
| 129 |
- DS1731: +/- 1.0 degree Celsius (from -10 to +85 degrees) |
| 130 |
|
| 131 |
.. Note:: |
| 132 |
|
| 133 |
Please refer to the device datasheets for accuracy at other temperatures. |
| 134 |
|
| 135 |
Temperature Resolution: |
| 136 |
----------------------- |
| 137 |
As mentioned above, the DS1631, DS1721, and DS1731 provide multi-resolution |
| 138 |
support, which is achieved via the R0 and R1 config register bits, where: |
| 139 |
|
| 140 |
R0..R1 |
| 141 |
------ |
| 142 |
|
| 143 |
== == =============================== |
| 144 |
R0 R1 |
| 145 |
== == =============================== |
| 146 |
0 0 9 bits, 0.5 degrees Celsius |
| 147 |
1 0 10 bits, 0.25 degrees Celsius |
| 148 |
0 1 11 bits, 0.125 degrees Celsius |
| 149 |
1 1 12 bits, 0.0625 degrees Celsius |
| 150 |
== == =============================== |
| 151 |
|
| 152 |
.. Note:: |
| 153 |
|
| 154 |
At initial device power-on, the default resolution is set to 12-bits. |
| 155 |
|
| 156 |
The resolution mode for the DS1631, DS1721, or DS1731 can be changed from |
| 157 |
userspace, via the device 'update_interval' sysfs attribute. This attribute |
| 158 |
will normalize the range of input values to the device maximum resolution |
| 159 |
values defined in the datasheet as follows: |
| 160 |
|
| 161 |
============= ================== =============== |
| 162 |
Resolution Conversion Time Input Range |
| 163 |
(C/LSB) (msec) (msec) |
| 164 |
============= ================== =============== |
| 165 |
0.5 93.75 0....94 |
| 166 |
0.25 187.5 95...187 |
| 167 |
0.125 375 188..375 |
| 168 |
0.0625 750 376..infinity |
| 169 |
============= ================== =============== |
| 170 |
|
| 171 |
The following examples show how the 'update_interval' attribute can be |
| 172 |
used to change the conversion time:: |
| 173 |
|
| 174 |
$ cat update_interval |
| 175 |
750 |
| 176 |
$ cat temp1_input |
| 177 |
22062 |
| 178 |
$ |
| 179 |
$ echo 300 > update_interval |
| 180 |
$ cat update_interval |
| 181 |
375 |
| 182 |
$ cat temp1_input |
| 183 |
22125 |
| 184 |
$ |
| 185 |
$ echo 150 > update_interval |
| 186 |
$ cat update_interval |
| 187 |
188 |
| 188 |
$ cat temp1_input |
| 189 |
22250 |
| 190 |
$ |
| 191 |
$ echo 1 > update_interval |
| 192 |
$ cat update_interval |
| 193 |
94 |
| 194 |
$ cat temp1_input |
| 195 |
22000 |
| 196 |
$ |
| 197 |
$ echo 1000 > update_interval |
| 198 |
$ cat update_interval |
| 199 |
750 |
| 200 |
$ cat temp1_input |
| 201 |
22062 |
| 202 |
$ |
| 203 |
|
| 204 |
As shown, the ds1621 driver automatically adjusts the 'update_interval' |
| 205 |
user input, via a step function. Reading back the 'update_interval' value |
| 206 |
after a write operation provides the conversion time used by the device. |
| 207 |
|
| 208 |
Mathematically, the resolution can be derived from the conversion time |
| 209 |
via the following function: |
| 210 |
|
| 211 |
g(x) = 0.5 * [minimum_conversion_time/x] |
| 212 |
|
| 213 |
where: |
| 214 |
|
| 215 |
- 'x' = the output from 'update_interval' |
| 216 |
- 'g(x)' = the resolution in degrees C per LSB. |
| 217 |
- 93.75ms = minimum conversion time |