| 1 |
Light dependent resistors |
| 2 |
========================= |
| 3 |
|
| 4 |
The resistance of an LDR reduces with the intensity of light falling on it. |
| 5 |
This can be measured using the SEN terminal. |
| 6 |
|
| 7 |
Objective |
| 8 |
--------- |
| 9 |
|
| 10 |
Learn about LDR. Measure intensity of light and its variation with distance from the source. |
| 11 |
|
| 12 |
.. image:: schematics/ldr.svg |
| 13 |
:width: 300px |
| 14 |
|
| 15 |
Procedure |
| 16 |
--------- |
| 17 |
|
| 18 |
- Connect the LDR from SEN to ground |
| 19 |
- Connect a wire from SEN to A1 |
| 20 |
- Measure the LDR’s resistance, for different light intensities. |
| 21 |
- Iluminate LDR using a fluorescent lamp, A1 should show ripples |
| 22 |
- Set the time base to 200mS full scale |
| 23 |
|
| 24 |
Discussion |
| 25 |
---------- |
| 26 |
|
| 27 |
The resistance vary from 1kΩ to around 100 kΩ depending on the intensity |
| 28 |
of light falling on it. The voltage is proportional to the resistance. |
| 29 |
The resistance decreases with intensity of light. If you use a point |
| 30 |
source of light, the resistance should increase as the square of the |
| 31 |
distance between the LDR and the light source. The light from a fluorescent lamp operating at 50Hz |
| 32 |
has 100Hz ripples and these can be measured. |