Debian Codegraph @

eyesjunior/helpFiles/en/_sources/2.14.rst

raw
1 Light dependent resistors
2 =========================
3
4 The resistance of an LDR reduces with the intensity of light falling on it.
5 This can be measured using the SEN terminal.
6
7 Objective
8 ---------
9
10 Learn about LDR. Measure intensity of light and its variation with distance from the source.
11
12 .. image:: schematics/ldr.svg
13 :width: 300px
14
15 Procedure
16 ---------
17
18 - Connect the LDR from SEN to ground
19 - Connect a wire from SEN to A1
20 - Measure the LDR’s resistance, for different light intensities.
21 - Iluminate LDR using a fluorescent lamp, A1 should show ripples
22 - Set the time base to 200mS full scale
23
24 Discussion
25 ----------
26
27 The resistance vary from 1kΩ to around 100 kΩ depending on the intensity
28 of light falling on it. The voltage is proportional to the resistance.
29 The resistance decreases with intensity of light. If you use a point