eyes17/html/opamp-inv.html
raw| 1 | <h2 id="schematic">Schematic</h2> |
| 2 | <hr> |
| 3 | <p><img src="images/opamp-inv.png" alt=""></p> |
| 4 | <h2 id="instructions">Instructions</h2> |
| 5 | <hr> |
| 6 | <ul> |
| 7 | <li>Use the Oscilloscope to test the Inverting Amplifier.</li> |
| 8 | <li>Enable A1, A2 and their analysis option</li> |
| 9 | <li>Set WG amplitude to 100 mV.</li> |
| 10 | <li>Set the range of A1 to 0.5 V and range of A2 to 4V.</li> |
| 11 | <li>Monitor the traces.</li> |
| 12 | <li>Change the gain by changing one of the resistors. Gain = -Rf/Ri</li> |