1 <?xml version="1.0"?>
2 <!--
3 Heatit Z-Water
4 https://products.z-wavealliance.org/products/3102
5 -->
6 <Product xmlns="https://github.com/OpenZWave/open-zwave" Revision="3">
7 <MetaData>
8 <MetaDataItem name="ProductPic">images/thermofloor/heatit20a.png</MetaDataItem>
9 <MetaDataItem id="020a" name="ZWProductPage" type="0003">https://products.z-wavealliance.org/products/3102/</MetaDataItem>
10 <MetaDataItem name="InclusionDescription">Adding the device:
11 When the primary controller is set to add/remove modus press the &#x201D;INCLUSION&#x201D; button once on the device</MetaDataItem>
12 <MetaDataItem id="020a" name="Identifier" type="0003">Z-Water</MetaDataItem>
13 <MetaDataItem name="Description">Heatit Z-Water is equipped with 10 relay outputs and 4 analog inputs, and a Z-Wave radio for interfacing to the wireless
14 Z-Wave network.
15 The regulator can be power supplied from a 230V AC mains connection, and is able to deliver an output supply of 24V DC.
16 Heatit Z-Water relay outputs are able to be freely controlled from the Z-Wave network, and can be used for several
17 purposes, e.g. on/off control of light, control of valve actuators for an underfloor heating system, or control of other home
18 automation systems.
19 Heatit Z-Water inputs are analog inputs for interfacing simple temperature sensors; NTC, PT1000, etc.
20 It is possible to configure the level and the indication of the status indicator LED in the front of the Heatit Z-Water
21 regulator.</MetaDataItem>
22 <MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/3102/Manual_Heatit_Z-Water_analog%20inputs_FW%202.1_Ver2019-A_ENG.pdf</MetaDataItem>
23 <MetaDataItem name="ExclusionDescription">Removing the device: When the primary controller is set to add/remove modus press the &#x201D;INCLUSION&#x201D; button once on the device</MetaDataItem>
24 <MetaDataItem id="020a" name="FrequencyName" type="0003">CEPT (Europe)</MetaDataItem>
25 <MetaDataItem name="ResetDescription">By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset.
26 NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable.</MetaDataItem>
27 <MetaDataItem name="Name">Heatit Z-Water</MetaDataItem>
28 <ChangeLog>
29 <Entry author="Espen Throndsen - [email protected]" date="21 Oct 2019" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3102/xml</Entry>
30 <Entry author="Lars Tobias Skjong-B&#xF8;rsting - [email protected]" date="28 Jun 2020" revision="2">Added ProductPic</Entry>
31 <Entry author="Lars Tobias Skjong-B&#xF8;rsting - [email protected]" date="12 Jul 2020" revision="3">Fixed errors</Entry>
32 </ChangeLog>
33 </MetaData>
34 <CommandClass id="112">
35 <Value genre="config" index="1" label="status LED" size="1" type="list" value="1">
36 <Help>Set LED mode</Help>
37 <Item label="LED turned off" value="0"/>
38 <Item label="LED turned on.(default)" value="1"/>
39 <Item label="2 LED flashing at 1 second intervals (&#xBD; Hz)" value="2"/>
40 <Item label="3 LED flashing at &#xBD; second interval (1 Hz)" value="3"/>
41 </Value>
42 <Value genre="config" index="2" instance="1" label="Specifies the brightness level of the LED when it is on.(0-100) Default is 50" size="1" type="byte" value="50">
43 <Help>Set Brightnes</Help>
44 </Value>
45 <Value genre="config" index="3" instance="1" label="Thermistor type connected to input 1" size="1" type="list" value="0">
46 <Help>This parameter decides which kind of thermistor that is connected to the input.</Help>
47 <Item label="0 No thermistor, input is disabled" value="0"/>
48 <Item label="1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)" value="1"/>
49 </Value>
50 <Value genre="config" index="4" instance="1" label="Thermistor type connected to input 2" size="1" type="list" value="0">
51 <Help>This parameter decides which kind of thermistor that is connected to the input.</Help>
52 <Item label="0 No thermistor, input is disabled" value="0"/>
53 <Item label="1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)" value="1"/>
54 </Value>
55 <Value genre="config" index="5" instance="1" label="Thermistor type connected to input 3" size="1" type="list" value="0">
56 <Help>This parameter decides which kind of thermistor that is connected to the input.</Help>
57 <Item label="0 No thermistor, input is disabled" value="0"/>
58 <Item label="1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)" value="1"/>
59 </Value>
60 <Value genre="config" index="6" instance="1" label="Thermistor type connected to input 4" size="1" type="list" value="0">
61 <Help>This parameter decides which kind of thermistor that is connected to the input.</Help>
62 <Item label="0 No thermistor, input is disabled" value="0"/>
63 <Item label="1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)" value="1"/>
64 </Value>
65 <Value genre="config" index="7" instance="1" label="Input 1 calibration" size="1" type="byte" max="255" min="0" value="0">
66 <Help>-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.</Help>
67 </Value>
68 <Value genre="config" index="8" instance="1" label="Input 2 calibration" size="1" type="byte" max="255" min="0" value="0">
69 <Help>-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.</Help>
70 </Value>
71 <Value genre="config" index="9" instance="1" label="Input 3 calibration" size="1" type="byte" max="255" min="0" value="0">
72 <Help>-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.</Help>
73 </Value>
74 <Value genre="config" index="10" instance="1" label="Input 4 calibration" size="1" type="byte" max="255" min="0" value="0">
75 <Help>-40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value.</Help>
76 </Value>
77 <Value genre="config" index="11" instance="1" label="Input 1 Temperature report interval" max="8640" min="0" size="2" type="short" value="60">
78 <Help>
79 0 (Report disabled)
80 Multiply with 10 seconds, 10 seconds &#x2013; 24 hours. Default is 6 (60 seconds).</Help>
81 </Value>
82 <Value genre="config" index="12" instance="1" label="Input 2 Temperature report interval" max="8640" min="0" size="2" type="short" value="60">
83 <Help>
84 0 (Report disabled)
85 Multiply with 10 seconds, 10 seconds &#x2013; 24 hours. Default is 6 (60 seconds).</Help>
86 </Value>
87 <Value genre="config" index="13" instance="1" label="Input 3 Temperature report interval" max="8640" min="0" size="2" type="short" value="60">
88 <Help>
89 0 (Report disabled)
90 Multiply with 10 seconds, 10 seconds &#x2013; 24 hours. Default is 6 (60 seconds).</Help>
91 </Value>
92 <Value genre="config" index="14" instance="1" label="Input 4 Temperature report interval" max="8640" min="0" size="2" type="short" value="60">
93 <Help>
94 0 (Report disabled)
95 Multiply with 10 seconds, 10 seconds &#x2013; 24 hours. Default is 6 (60 seconds).</Help>
96 </Value>
97 <Compatibility/>
98 </CommandClass>
99 <CommandClass id="133">
100 <Associations num_groups="5">
101 <Group index="1" label="Lifeline. - Reset notification - Basic Report On / Off - Multilevel Sensor Report" max_associations="5"/>
102 <Group index="2" label="Sends Multilevel Sensor Reports for input 1" max_associations="5"/>
103 <Group index="3" label="Sends Multilevel Sensor Reports for input 2" max_associations="5"/>
104 <Group index="4" label="Sends Multilevel Sensor Reports for input 3" max_associations="5"/>
105 <Group index="5" label="Sends Multilevel Sensor Reports for input 4" max_associations="5"/>
106 </Associations>
107 <Compatibility/>
108 </CommandClass>
109 <!-- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2-->
110 <CommandClass id="142">
111 <Compatibility>
112 <ForceInstances>true</ForceInstances>
113 </Compatibility>
114 </CommandClass>
115 <!--COMMAND_CLASS_MULTI_CHANNEL_V2 Map endpoints to instances -->
116 <CommandClass id="96">
117 <Compatibility>
118 <MapRootToEndpoint>true</MapRootToEndpoint>
119 </Compatibility>
120 </CommandClass>
121 </Product>