<?xml version="1.0" encoding="utf-8" ?> |
| 2 |
<Product Revision="1" |
| 3 |
xmlns="https://github.com/OpenZWave/open-zwave"> |
| 4 |
<MetaData> |
| 5 |
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/019B:0201:0003</MetaDataItem> |
| 6 |
<MetaDataItem name="ProductPic">images/thermofloor/heatit021.png</MetaDataItem> |
| 7 |
<MetaDataItem id="0201" name="ZWProductPage" type="0003">https://products.z-wavealliance.org/products/1234/</MetaDataItem> |
| 8 |
<MetaDataItem name="Description">Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that |
| 9 |
can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others. |
| 10 |
The display will show the actual room temperature. By pressing the buttons, the display will show the set value. |
| 11 |
Heatit Z-Wave is equipped with a single-pole switch. |
| 12 |
The thermostat can handle loads up to 16A/3600Wat 230V. If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors. |
| 13 |
|
| 14 |
FUNCTIONS |
| 15 |
• Room sensor |
| 16 |
• Floor sensor |
| 17 |
• Temperature limiter |
| 18 |
• Power regulator |
| 19 |
• Z-Wave chip 500 series |
| 20 |
• Week program/setback temperature via gateway |
| 21 |
• Setback mode |
| 22 |
• 7-segment LCD-screen |
| 23 |
• Can be used in connection with diff erent NTC-sensors |
| 24 |
• Lock mode/child lock |
| 25 |
• Backlight |
| 26 |
• Calibration |
| 27 |
• 8 scenarios |
| 28 |
CONNECTION CLAMPS |
| 29 |
Use 1,5 mm² or 2,5 mm² cables according to power need. |
| 30 |
TECHNICAL DATA |
| 31 |
Display LED-display 3x 7-Seg 13.2mm CA white |
| 32 |
Rated voltage: 230V 50/60Hz |
| 33 |
Max. load: 3600W |
| 34 |
Max. current: 16A |
| 35 |
Power consumption: 1,5W |
| 36 |
Protection class: IP21 |
| 37 |
Min/Max installation temp: -20°C to 40°C |
| 38 |
Min/Max operating temp: 5°C to 40°C |
| 39 |
Temperature range +5°C/+40°C |
| 40 |
Displayed temperature -30°C …. 60°C |
| 41 |
Floor min. limit 5°C (5°C…35°C) |
| 42 |
Floor max. limit 35°C (5°C…35°C) |
| 43 |
Air min. limit 5°C (5°C…40°C) |
| 44 |
Air max. limit 35°C (5°C…40°C) |
| 45 |
Regulator min. limit 0 (0…9) |
| 46 |
Power regulator P02 (P00…P10) cycle of 30 minutes |
| 47 |
Temperature setback Adjustable within temperature range. |
| 48 |
Temperature setback activation Pilot wire/Z-Wave user interface |
| 49 |
Hysteresis: 0,5°C |
| 50 |
Sensor values: 0°C 29,1 kOhm |
| 51 |
10°C 18,6 kOhm |
| 52 |
15°C 15,1 kOhm |
| 53 |
20°C 12,2 kOhm |
| 54 |
25°C 10,0 kOhm |
| 55 |
Switch: Single-pole |
| 56 |
Standard Color White RAL 9003 – Black RAL 9011 |
| 57 |
Approvals CE – FIMKO - Z-Wave Plus |
| 58 |
</MetaDataItem> |
| 59 |
<MetaDataItem name="ExclusionDescription">INCLUSION/EXCLUSION |
| 60 |
To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. |
| 61 |
The display will show OFF. Press Right (down) 4 times till you see Con in the display. |
| 62 |
Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately |
| 63 |
2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion |
| 64 |
fails, Err (error) will appear. |
| 65 |
Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem> |
| 66 |
<MetaDataItem name="ProductManual">https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1182/Manual_Multireg%20Z-Wave_Ver2015-A.pdf</MetaDataItem> |
| 67 |
<MetaDataItem id="0001" name="FrequencyName" type="0001">CEPT (Europe)</MetaDataItem> |
| 68 |
<MetaDataItem name="Name">Heatit Z-Wave</MetaDataItem> |
| 69 |
<MetaDataItem id="0001" name="Identifier" type="0001">TF021</MetaDataItem> |
| 70 |
<MetaDataItem name="ResetDescription">FACTORY RESET - RES |
| 71 |
By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset. |
| 72 |
NB! Please use this procedure only when the primary controller is missing or otherwise inoperable.</MetaDataItem> |
| 73 |
<MetaDataItem name="InclusionDescription">INCLUSION/EXCLUSION |
| 74 |
To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. |
| 75 |
The display will show OFF. Press Right (down) 4 times till you see Con in the display. |
| 76 |
Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately |
| 77 |
2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion |
| 78 |
fails, Err (error) will appear. |
| 79 |
Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem> |
| 80 |
<MetaDataItem name="WakeupDescription">If Er2 appears in the display, touch any button to restart the display.</MetaDataItem> |
| 81 |
<ChangeLog> |
| 82 |
<Entry author="Pål Kristensen - [email protected]" date="11 January 2021" revision="1">Initial release</Entry> |
| 83 |
</ChangeLog> |
| 84 |
</MetaData> |
| 85 |
|
| 86 |
<CommandClass id="32"> |
| 87 |
<Compatibility> |
| 88 |
<Mapping>37</Mapping> |
| 89 |
</Compatibility> |
| 90 |
</CommandClass> |
| 91 |
<CommandClass id="49"> |
| 92 |
<Value type="decimal" genre="user" instance="1" index="1" label="Internal Air Temperature Sensor" units="C" read_only="true" write_only="false"/> |
| 93 |
<Value type="decimal" genre="user" instance="2" index="1" label="External Air Temperature Sensor" units="C" read_only="true" write_only="false"/> |
| 94 |
<Value type="decimal" genre="user" instance="3" index="1" label="External Floor Temperature Sensor" units="C" read_only="true" write_only="false"/> |
| 95 |
<Compatibility> |
| 96 |
<Base>0</Base> |
| 97 |
<CreateVars>true</CreateVars> |
| 98 |
</Compatibility> |
| 99 |
</CommandClass> |
| 100 |
<CommandClass id="64"> |
| 101 |
<Value genre="user" index="0" instance="1" label="Mode" max="0" min="0" read_only="false" size="1" type="list" units="" value="0" write_only="false"> |
| 102 |
<Item label="Off" value="0"/> |
| 103 |
<Item label="Heat" value="1"/> |
| 104 |
<Item label="Cool" value="2"/> |
| 105 |
<Item label="Energy Heat" value="11"/> |
| 106 |
</Value> |
| 107 |
<SupportedModes> |
| 108 |
<Mode index="0" label="Off"/> |
| 109 |
<Mode index="1" label="Heat"/> |
| 110 |
<Mode index="2" label="Cool"/> |
| 111 |
<Mode index="11" label="Energy Heat"/> |
| 112 |
</SupportedModes> |
| 113 |
</CommandClass> |
| 114 |
|
| 115 |
<CommandClass id="67"> |
| 116 |
<Instance index="1"/> |
| 117 |
<Value type="decimal" genre="user" instance="1" index="1" label="Heating" units="C" read_only="false" write_only="false" min="0" max="0" value="20"/> |
| 118 |
<Value type="decimal" genre="user" instance="1" index="2" label="Cooling" units="C" read_only="false" write_only="false" min="0" max="0" value="21"/> |
| 119 |
<Value type="decimal" genre="user" instance="1" index="11" label="Energy Heat" units="C" read_only="false" write_only="false" min="0" max="0" value="16"/> |
| 120 |
<Compatibility> |
| 121 |
<Base>0</Base> |
| 122 |
<CreateVars>true</CreateVars> |
| 123 |
</Compatibility> |
| 124 |
</CommandClass> |
| 125 |
|
| 126 |
<CommandClass id="112"> |
| 127 |
<Value type="list" genre="config" index="1" label="Operation mode" value="1" size="1"> |
| 128 |
<Help>Set operation mode</Help> |
| 129 |
<Item label="Off" value="0"/> |
| 130 |
<Item label="Heat" value="1"/> |
| 131 |
<Item label="Cool" value="2"/> |
| 132 |
<Item label="Energy save heat" value="11"/> |
| 133 |
</Value> |
| 134 |
<Value type="list" genre="config" index="2" label="Sensor mode" value="1" size="1"> |
| 135 |
<Help>Set sensor mode</Help> |
| 136 |
<Item label="F - Floor sensor" value="0"/> |
| 137 |
<Item label="A - Internal room sensor" value="1"/> |
| 138 |
<Item label="AF - Internal room sensor and floor sensor" value="2"/> |
| 139 |
<Item label="A2 - External room sensor" value="3"/> |
| 140 |
<Item label="P - Power regulator" value="4"/> |
| 141 |
<Item label="FP - Floor sensor and power regulator" value="5"/> |
| 142 |
</Value> |
| 143 |
<Value type="list" genre="config" index="3" label="Floor sensor type" value="0" size="1"> |
| 144 |
<Help>Floor sensor type (10K NTC Default)</Help> |
| 145 |
<Item label="10k ntc" value="0"/> |
| 146 |
<Item label="12k ntc" value="1"/> |
| 147 |
<Item label="15k ntc" value="2"/> |
| 148 |
<Item label="22k ntc" value="3"/> |
| 149 |
<Item label="33k ntc" value="4"/> |
| 150 |
<Item label="47k ntc" value="5"/> |
| 151 |
</Value> |
| 152 |
<Value type="byte" index="4" genre="config" label="DIFF l. Temperature control Hysteresis" min="0" max="30" size="1" value="5"> |
| 153 |
<Help>0-30 (0,3C - 3.0C)</Help> |
| 154 |
</Value> |
| 155 |
<Value type="short" index="5" genre="config" label="FLo: Floor min limit" min="50" max="400" size="2" value="50"> |
| 156 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 157 |
</Value> |
| 158 |
<Value type="short" index="6" genre="config" label="FHi: Floor max limit" min="50" max="400" size="2" value="400"> |
| 159 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 160 |
</Value> |
| 161 |
<Value type="short" index="7" genre="config" label="ALo: Air min limit" min="50" max="400" size="2" value="50"> |
| 162 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 163 |
</Value> |
| 164 |
<Value type="short" index="8" genre="config" label="AHi: Air max limit" min="50" max="400" size="2" value="400"> |
| 165 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 166 |
</Value> |
| 167 |
<Value type="byte" index="9" genre="config" label="PLo: Min power in FP-mode" min="0" max="9" size="1" value="0"> |
| 168 |
<Help>Min power 0-9 in FP-mode (Floor sensor and power regulator mode)</Help> |
| 169 |
</Value> |
| 170 |
<Value type="short" genre="config" instance="1" index="10" label="CO mode setpoint" size="2" min="50" max="400" value="210"> |
| 171 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 172 |
</Value> |
| 173 |
<Value type="short" genre="config" instance="1" index="11" label="ECO mode setpoint" size="2" min="50" max="400" value="180"> |
| 174 |
<Help>50-400 (5.0C - 40.0C)</Help> |
| 175 |
</Value> |
| 176 |
<Value type="byte" index="12" genre="config" label="P setting" min="0" max="10" size="1" value="2"> |
| 177 |
<Help>Power 0-10 in P-mode (Power regulator mode)</Help> |
| 178 |
</Value> |
| 179 |
<Value type="short" genre="config" instance="1" index="13" label="COOL setpoint" size="2" min="50" max="400" value="210"> |
| 180 |
<Help>Only if cooling is enabled. 50-400 (5.0C - 40.0C)</Help> |
| 181 |
</Value> |
| 182 |
<Value type="byte" index="14" genre="config" label="Room sensor calibration" min="0" max="40" size="1" value="0"> |
| 183 |
<Help>Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat)</Help> |
| 184 |
</Value> |
| 185 |
<Value type="byte" index="15" genre="config" label="Floor sensor calibration" min="0" max="40" size="1" value="0"> |
| 186 |
<Help>Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat)</Help> |
| 187 |
</Value> |
| 188 |
<Value type="byte" index="16" genre="config" label="External sensor calibration" min="0" max="40" size="1" value="0"> |
| 189 |
<Help>Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat)</Help> |
| 190 |
</Value> |
| 191 |
<Value type="short" index="17" genre="config" label="Temperature report interval" min="0" max="8640" size="2" value="6"> |
| 192 |
<Help> 0 (Report disabled) 1-8640 Multiply with 10 seconds, 10 seconds - 24 hours. Default is 6 (60 seconds)</Help> |
| 193 |
</Value> |
| 194 |
<Value type="byte" index="18" genre="config" label="Temperature report hysteresis" min="1" max="100" size="1" value="10"> |
| 195 |
<Help>1-100 (0.1C - 10C). Default is 10 (1.0C)</Help> |
| 196 |
</Value> |
| 197 |
</CommandClass> |
| 198 |
<CommandClass id="133"> |
| 199 |
<Associations num_groups="5"> |
| 200 |
<Group index="1" max_associations="2" label="Lifeline"/> |
| 201 |
<Group index="2" max_associations="2" label="On/Off control"/> |
| 202 |
<Group index="3" max_associations="2" label="Multilevel sensor reports - Internal sensor" auto="true" /> |
| 203 |
<Group index="4" max_associations="2" label="Multilevel sensor reports - External sensor" /> |
| 204 |
<Group index="5" max_associations="2" label="Multilevel sensor reports - Floor sensor" auto="true" /> |
| 205 |
</Associations> |
| 206 |
</CommandClass> |
| 207 |
|
| 208 |
<!-- COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2--> |
| 209 |
<CommandClass id="142"> |
| 210 |
<Compatibility> |
| 211 |
<ForceInstances>true</ForceInstances> |
| 212 |
</Compatibility> |
| 213 |
</CommandClass> |
| 214 |
|
| 215 |
<!--COMMAND_CLASS_MULTI_CHANNEL_V2 Map endpoints to instances --> |
| 216 |
<CommandClass id="96"> |
| 217 |
<Compatibility> |
| 218 |
<MapRootToEndpoint>true</MapRootToEndpoint> |
| 219 |
</Compatibility> |
| 220 |
</CommandClass> |
| 221 |
</Product> |