| 1 |
<?xml version="1.0" encoding="utf-8"?> |
| 2 |
<Product Revision="1" xmlns="https://github.com/OpenZWave/open-zwave"> |
| 3 |
<MetaData> |
| 4 |
<MetaDataItem name="Name">Heatit Z-Temp2</MetaDataItem> |
| 5 |
<MetaDataItem name="Description">Heatit Z-Temp2 is a battery-operated thermostat designed for use with water based heating systems. Used in combination with the Heatit Z-Water regulator you can control your heating system with a Z-Wave primary controller/gateway with the use of Heatit Z-Water in combination with one or several Heatit Z-Temp2. </MetaDataItem> |
| 6 |
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/019B:0204:0004</MetaDataItem> |
| 7 |
<MetaDataItem name="ProductPage">https://products.z-wavealliance.org/products/3860</MetaDataItem> |
| 8 |
<MetaDataItem name="ProductSupport">https://www.heatit.com/z-wave/heatit-z-temp-2-2/</MetaDataItem> |
| 9 |
<MetaDataItem name="ProductPic">images/thermofloor/heatit0204.png</MetaDataItem> |
| 10 |
<MetaDataItem name="ProductManual">https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3860/Manual_Heatit_Z-Temp2_FW%201.1_Ver2020-A_ENG.pdf</MetaDataItem> |
| 11 |
<MetaDataItem name="WakeupDescription">The thermostat is a FLIRS device. You are able to force a Node Information Frame using the same procedure as adding/removing procedure; "press the link button on the thermostat 3 times in a rapid sequence." </MetaDataItem> |
| 12 |
<MetaDataItem name="InclusionDescription">There are two ways to add your devices in a Z-Wave network. * Standard (manual). Please refer to your primary controller/gateway manual on how to enter add mode. The device can only be added to the network if the primary controller is in add mode. When the primary controller/gateway is set to add mode press the link button on the thermostat 3 times in a rapid sequence. * SmartStart (automatic) Please refer to your primary controller/gateway to see if SmartStart is supported by the controller. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR-Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.</MetaDataItem> |
| 13 |
<MetaDataItem name="ExclusionDescription">Remove. Please refer to your primary controller/gateway manual on how to enter remove mode. The device can only be removed from the network if the primary controller is in remove mode. When the primary controller/gateway is set to remove modus press the link button on the thermostat 3 times in a rapid sequence.</MetaDataItem> |
| 14 |
<MetaDataItem name="ResetDescription">By pressing and holding the link button for 20 seconds, the thermostat will perform a complete factory reset. rES will be displayed. NB! Please use this procedure only when the primary controller/gateway is missing or otherwise inoperable.</MetaDataItem> |
| 15 |
<MetaDataItem id="0204" name="ZWProductPage" type="0004">https://products.z-wavealliance.org/products/XXXX/</MetaDataItem> |
| 16 |
<MetaDataItem id="0204" name="FrequencyName" type="0004">CEPT (Europe)</MetaDataItem> |
| 17 |
<MetaDataItem id="0204" name="Identifier" type="0004">Z-Temp2</MetaDataItem> |
| 18 |
<ChangeLog> |
| 19 |
<Entry author="Julien Ithurbide - [email protected]" date="26 Oct 2020" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3860/xml</Entry> |
| 20 |
</ChangeLog> |
| 21 |
</MetaData> |
| 22 |
|
| 23 |
<!-- Thermostat --> |
| 24 |
<!-- COMMAND_CLASS_THERMOSTAT_MODE 0x40 64 --> |
| 25 |
<CommandClass id="64"> |
| 26 |
<Value genre="user" index="0" instance="1" label="Mode" max="0" min="0" read_only="false" type="list" units="" value="0" write_only="false"> |
| 27 |
<Item label="Off" value="0"/> |
| 28 |
<Item label="Heat" value="1"/> |
| 29 |
</Value> |
| 30 |
<SupportedModes> |
| 31 |
<Mode index="0" label="Off"/> |
| 32 |
<Mode index="1" label="Heat"/> |
| 33 |
</SupportedModes> |
| 34 |
<Compatibility> |
| 35 |
<Base>0</Base> |
| 36 |
<CreateVars>true</CreateVars> |
| 37 |
</Compatibility> |
| 38 |
</CommandClass> |
| 39 |
|
| 40 |
<!-- COMMAND_CLASS_THERMOSTAT_SETPOINT 0x43 67 --> |
| 41 |
<CommandClass id="67"> |
| 42 |
<Instance index="1"/> |
| 43 |
<Value genre="user" index="1" instance="1" label="Heating setpoint" max="40" min="0" read_only="false" type="decimal" units="C" value="20" write_only="false"/> |
| 44 |
<Compatibility> |
| 45 |
<Base>0</Base> |
| 46 |
<CreateVars>true</CreateVars> |
| 47 |
</Compatibility> |
| 48 |
</CommandClass> |
| 49 |
|
| 50 |
|
| 51 |
<CommandClass id="112"> |
| 52 |
<Value genre="config" index="1" instance="1" label="Temperature/ Humidity report interval" max="32767" min="30" size="2" type="short" value="900"> |
| 53 |
<Help>Used to adjust the time between report interval for Temperature and humidity reports. Min is 30, max is 32767 and default is 900</Help> |
| 54 |
</Value> |
| 55 |
<Value genre="config" index="2" instance="1" label="Temperature delta value" max="50" min="0" size="2" type="short" value="10"> |
| 56 |
<Help>Temperature delta value. Value 0 : Reporting temperature based on change is disabled. Real value : + 0.5 to + 5°C (Default 10 corresponding to 1.0°C)</Help> |
| 57 |
</Value> |
| 58 |
<Value genre="config" index="3" instance="1" label="Humidity delta value" max="50" min="0" size="2" type="short" value="10"> |
| 59 |
<Help>Humidity delta value. Value 0 : Reporting Humidity based on change is disabled. Real value : + 0.5 to + 5°C (Default 10 corresponding to 1.0°C)</Help> |
| 60 |
</Value> |
| 61 |
<Value genre="config" index="4" instance="1" label="Temperature offset settings" max="65535" min="0" size="2" type="short" value="0"> |
| 62 |
<Help>Calibrate the internal temperature sensor. NB! To set negative values; 65 535 – desired value + 1. Value: -100 to 100°C (Default 0, 0°C)</Help> |
| 63 |
</Value> |
| 64 |
<Value genre="config" index="5" instance="1" label="Humidity offset settings" max="65535" min="0" size="2" type="short" value="0"> |
| 65 |
<Help>Calibrate the internal hunidity sensor. NB! To set negative values; 65 535 – desired value + 1. Value: -100 to 100°C (Default 0, 0°C)</Help> |
| 66 |
</Value> |
| 67 |
<Value genre="config" index="6" instance="1" label="Proximity sensor retrigger interval" max="270" min="2" size="2" type="short" value="10"> |
| 68 |
<Help>value 2 to 270 seconds (Default 10, 10 seconds)</Help> |
| 69 |
</Value> |
| 70 |
<Value genre="config" index="7" instance="1" label="Proximity sensor Enable / Disable" max="1" min="0" size="2" type="short" value="1"> |
| 71 |
<Help>Disable or enable sensor. Value 0 disable, 1 enable </Help> |
| 72 |
</Value> |
| 73 |
<Value genre="config" index="8" instance="1" label="LED maximum brightness" max="99" min="0" size="2" type="short" value="50"> |
| 74 |
<Help>Adjust the backlight of LCD display.</Help> |
| 75 |
</Value> |
| 76 |
<Value genre="config" index="9" instance="1" label="LED turned on before timeout" max="300" min="3" size="2" type="short" value="3"> |
| 77 |
<Help>Adjust the time from proximity sensor / display touched until display goes to sleep.Value 3 to 300 seconds (Default 3, 3 seconds)</Help> |
| 78 |
</Value> |
| 79 |
<Value genre="config" index="10" instance="1" label="Temperature Control Hysteresis" max="30" min="3" size="2" type="short" value="5"> |
| 80 |
<Help>Adjust the delta values for the thermostat to turn on off heating .Value 0.3 to 3°C (Default 5, 0,5°C)</Help> |
| 81 |
</Value> |
| 82 |
<Value genre="config" index="11" instance="1" label="Minimum Temperature Limit" max="400" min="50" size="2" type="short" value="50"> |
| 83 |
<Help>Set the mimum temperature limit.Value 5 to 40°C (Default 50, 5°C)</Help> |
| 84 |
</Value> |
| 85 |
<Value genre="config" index="12" instance="1" label="Maximum Temperature Limit" max="400" min="50" size="2" type="short" value="400"> |
| 86 |
<Help>Set the maximum temperature limit.5 to 40°C (Default 400, 40°C)</Help> |
| 87 |
</Value> |
| 88 |
<Value genre="config" index="13" instance="1" label="External Relay and Operating State update interval " max="240" min="0" size="2" type="short" value="0"> |
| 89 |
<Help>Set time on how often the devices sends Binary Switch Set and thermostat mode to gateway. Value 0 : Sends only when changed (Default). 1 to 240 minutes + When changed </Help> |
| 90 |
</Value> |
| 91 |
<Value genre="config" index="14" instance="1" label="Report when presence is detected" max="1" min="0" size="2" type="short" value="400"> |
| 92 |
<Help>Decides if the thermostat sends temperature when presence is detected.Value 0 : Do not report to gateway when presence is detected, only at interval.(Default) 1 : Send temperature report to gateway when presence is detected.</Help> |
| 93 |
</Value> |
| 94 |
</CommandClass> |
| 95 |
<CommandClass id="132"> |
| 96 |
<Associations num_groups="3"> |
| 97 |
<Group index="1" label="Lifeline" max_associations="5"/> |
| 98 |
<Group index="2" label="Temperature Report" max_associations="5"/> |
| 99 |
<Group index="3" label="Binary Switch Set (normally used to control external relays)." max_associations="5"/> |
| 100 |
</Associations> |
| 101 |
</CommandClass> |
| 102 |
|
| 103 |
</Product> |