Debian Codegraph @

config/thermofloor/heatit021.xml

raw
1 <Product Revision="9" xmlns="https://github.com/OpenZWave/open-zwave">
2 <MetaData>
3 <MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/019B:0001:0001</MetaDataItem>
4 <MetaDataItem name="ProductPic">images/thermofloor/heatit021.png</MetaDataItem>
5 <MetaDataItem id="0001" name="ZWProductPage" type="0001">https://products.z-wavealliance.org/products/1234/</MetaDataItem>
6 <MetaDataItem id="0201" name="ZWProductPage" type="0003">https://products.z-wavealliance.org/products/1182/</MetaDataItem>
7 <MetaDataItem name="Description">Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that
8 can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others.
9 The display will show the actual room temperature. By pressing the buttons, the display will show the set value.
10 Heatit Z-Wave is equipped with a single-pole switch.
11 The thermostat can handle loads up to 16A/3600Wat 230V. If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors.
12
13 FUNCTIONS
14 • Room sensor
15 • Floor sensor
16 • Temperature limiter
17 • Power regulator
18 • Z-Wave chip 500 series
19 • Week program/setback temperature via gateway
20 • Setback mode
21 • 7-segment LCD-screen
22 • Can be used in connection with diff erent NTC-sensors
23 • Lock mode/child lock
24 • Backlight
25 • Calibration
26 • 8 scenarios
27 CONNECTION CLAMPS
28 Use 1,5 mm² or 2,5 mm² cables according to power need.
29 TECHNICAL DATA
30 Rated voltage: 230V 50/60Hz
31 Max. load: 3600W
32 Max. current: 16A
33 Power consumption: 1,5W
34 Protection class: IP21
35 Min/Max installation temp: -20°C to 40°C
36 Min/Max operating temp: 5°C to 40°C
37 Temperature intervals: Floor sensor 5°C to 40°C
38 Room sensor 5°C to 40°C
39 Hysteresis: 0,5°C
40 Sensor values: 0°C 29,1 kOhm
41 10°C 18,6 kOhm
42 15°C 15,1 kOhm
43 20°C 12,2 kOhm
44 25°C 10,0 kOhm
45 Switch: Single-pole</MetaDataItem>
46 <MetaDataItem name="ExclusionDescription">INCLUSION/EXCLUSION
47 To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.
48 The display will show OFF. Press Right (down) 4 times till you see Con in the display.
49 Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately
50 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion
51 fails, Err (error) will appear.
52 Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem>
53 <MetaDataItem name="ProductManual">https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&amp;filename=Manuals/1234/Manual_Multireg Z-Wave_Ver2015-A.pdf</MetaDataItem>
54 <MetaDataItem id="0001" name="FrequencyName" type="0001">CEPT (Europe)</MetaDataItem>
55 <MetaDataItem id="0201" name="FrequencyName" type="0003">CEPT (Europe)</MetaDataItem>
56 <MetaDataItem name="Name">Heatit Z-Wave</MetaDataItem>
57 <MetaDataItem id="0001" name="Identifier" type="0001">TF021</MetaDataItem>
58 <MetaDataItem id="0201" name="Identifier" type="0003">TF021</MetaDataItem>
59 <MetaDataItem name="ResetDescription">FACTORY RESET - RES
60 By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset.
61 NB! Please use this procedure only when the primary controller is missing or otherwise inoperable.</MetaDataItem>
62 <MetaDataItem name="InclusionDescription">INCLUSION/EXCLUSION
63 To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.
64 The display will show OFF. Press Right (down) 4 times till you see Con in the display.
65 Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately
66 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion
67 fails, Err (error) will appear.
68 Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings.</MetaDataItem>
69 <MetaDataItem name="WakeupDescription">If Er2 appears in the display, touch any button to restart the display.</MetaDataItem>
70 <ChangeLog>
71 <Entry author="Justin Hammond - [email protected]" date="08 May 2019" revision="7">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1182/xml</Entry>
72 <Entry author="Justin Hammond - [email protected]" date="08 May 2019" revision="8">Updated Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/1234/xml</Entry>
73 <Entry author="Gunnar Skjold - [email protected]" date="15 Nov 2020" revision="9">Assigned this config to TF016 as well - https://products.z-wavealliance.org/products/1182/xml</Entry>
74 </ChangeLog>
75 </MetaData>
76 <CommandClass id="64">
77 <Value genre="user" index="0" instance="1" label="Mode" max="0" min="0" read_only="false" size="1" type="list" units="" value="0" write_only="false">
78 <Item label="Off" value="0"/>
79 <Item label="Heat (Default)" value="1"/>
80 <Item label="Cool" value="2"/>
81 <Item label="Energy Heat" value="11"/>
82 </Value>
83 <SupportedModes>
84 <Mode index="0" label="Off"/>
85 <Mode index="1" label="Heat"/>
86 <Mode index="2" label="Cool"/>
87 <Mode index="11" label="Energy Heat"/>
88 </SupportedModes>
89 <Compatibility/>
90 </CommandClass>
91 <CommandClass id="67">
92 <Instance index="1"/>
93 <Value genre="user" index="1" instance="1" label="Heating" max="40" min="5" read_only="false" type="decimal" units="C" value="20" write_only="false"/>
94 <Value genre="user" index="2" instance="1" label="Cooling" max="40" min="5" read_only="false" type="decimal" units="C" value="21" write_only="false"/>
95 <Value genre="user" index="11" instance="1" label="Energy Heat" max="40" min="5" read_only="false" type="decimal" units="C" value="16" write_only="false"/>
96 <Compatibility>
97 <Base>0</Base>
98 <CreateVars>true</CreateVars>
99 </Compatibility>
100 </CommandClass>
101 <CommandClass id="112">
102 <Value genre="config" index="1" label="Operation mode" size="1" type="list" value="1">
103 <Item label="Off" value="0"/>
104 <Item label="Heat" value="1"/>
105 <Item label="Cool" value="2"/>
106 <Item label="Energy save heat" value="11"/>
107 </Value>
108 <Value genre="config" index="2" label="Temperature sensor" size="1" type="list" value="1">
109 <Item label="F - Floor mode" value="0"/>
110 <Item label="A - Room temperature mode" value="1"/>
111 <Item label="AF - Room mode w/floor limitations" value="2"/>
112 <Item label="A2 - Room temperature mode" value="3"/>
113 <Item label="P - Power regulator" value="4"/>
114 <Item label="FP - Floor mode with minimum power limitation" value="5"/>
115 </Value>
116 <Value genre="config" index="3" label="Floor sensor type" size="1" type="list" value="0">
117 <Item label="10k ntc" value="0"/>
118 <Item label="12k ntc" value="1"/>
119 <Item label="15k ntc" value="2"/>
120 <Item label="22k ntc" value="3"/>
121 <Item label="33k ntc" value="4"/>
122 <Item label="47k ntc" value="5"/>
123 </Value>
124 <Value genre="config" index="4" label="DIFF l. Temperature control Hysteresis" max="30" min="3" size="2" type="short" value="5">
125 <Help>3-30 (0.3C - 3.0C)</Help>
126 </Value>
127 <Value genre="config" index="5" label="FLo: Floor min limit" max="400" min="50" size="2" type="short" value="50">
128 <Help>50-400 (5.0C - 40.0C)</Help>
129 </Value>
130 <Value genre="config" index="6" label="FHi: Floor max limit" max="400" min="50" size="2" type="short" value="400">
131 <Help>50-400 (5.0C - 40.0C)</Help>
132 </Value>
133 <Value genre="config" index="7" label="ALo: Air min limit" max="400" min="50" size="2" type="short" value="50">
134 <Help>50-400 (5.0C - 40.0C)</Help>
135 </Value>
136 <Value genre="config" index="8" label="AHi: Air max limit" max="400" min="50" size="2" type="short" value="400">
137 <Help>50-400 (5.0C - 40.0C)</Help>
138 </Value>
139 <Value genre="config" index="9" label="PLo: Min temperature in Power Reg Mode" max="9" min="0" size="1" type="byte" value="0">
140 <Help>0-9. Min temperature in Power Regulator Mode (setting 2. Temperature sensor - P)</Help>
141 </Value>
142 <Value genre="config" index="10" instance="1" label="CO mode setpoint" max="400" min="50" size="2" type="short" value="210">
143 <Help>50-400 (5.0C - 40.0C)</Help>
144 </Value>
145 <Value genre="config" index="11" instance="1" label="ECO mode setpoint" max="400" min="50" size="2" type="short" value="180">
146 <Help>50-400 (5.0C - 40.0C)</Help>
147 </Value>
148 <Value genre="config" index="12" label="P setting" max="10" min="0" size="2" type="short" value="2">
149 <Help>0-10</Help>
150 </Value>
151 <Value genre="config" index="13" instance="1" label="COOL setpoint" max="400" min="50" size="2" type="short" value="180">
152 <Help>
153 Only if cooling is enabled.
154 50-400 (5.0C - 40.0C)
155 </Help>
156 </Value>
157 <Compatibility/>
158 </CommandClass>
159 <CommandClass id="133">
160 <Associations num_groups="2">
161 <Group index="1" label="Lifeline" max_associations="1"/>
162 <Group index="2" label="On/Off control" max_associations="8"/>
163 </Associations>