Heatit Z-Temp2 Heatit Z-Temp2 is a battery-operated thermostat designed for use with water based heating systems. Used in combination with the Heatit Z-Water regulator you can control your heating system with a Z-Wave primary controller/gateway with the use of Heatit Z-Water in combination with one or several Heatit Z-Temp2. http://www.openzwave.com/device-database/019B:0204:0004 https://products.z-wavealliance.org/products/3860 https://www.heatit.com/z-wave/heatit-z-temp-2-2/ images/thermofloor/heatit0204.png https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3860/Manual_Heatit_Z-Temp2_FW%201.1_Ver2020-A_ENG.pdf The thermostat is a FLIRS device. You are able to force a Node Information Frame using the same procedure as adding/removing procedure; "press the link button on the thermostat 3 times in a rapid sequence." There are two ways to add your devices in a Z-Wave network. * Standard (manual). Please refer to your primary controller/gateway manual on how to enter add mode. The device can only be added to the network if the primary controller is in add mode. When the primary controller/gateway is set to add mode press the link button on the thermostat 3 times in a rapid sequence. * SmartStart (automatic) Please refer to your primary controller/gateway to see if SmartStart is supported by the controller. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR-Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. Remove. Please refer to your primary controller/gateway manual on how to enter remove mode. The device can only be removed from the network if the primary controller is in remove mode. When the primary controller/gateway is set to remove modus press the link button on the thermostat 3 times in a rapid sequence. By pressing and holding the link button for 20 seconds, the thermostat will perform a complete factory reset. rES will be displayed. NB! Please use this procedure only when the primary controller/gateway is missing or otherwise inoperable. https://products.z-wavealliance.org/products/XXXX/ CEPT (Europe) Z-Temp2 Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3860/xml 0 true 0 true Used to adjust the time between report interval for Temperature and humidity reports. Min is 30, max is 32767 and default is 900 Temperature delta value. Value 0 : Reporting temperature based on change is disabled. Real value : + 0.5 to + 5°C (Default 10 corresponding to 1.0°C) Humidity delta value. Value 0 : Reporting Humidity based on change is disabled. Real value : + 0.5 to + 5°C (Default 10 corresponding to 1.0°C) Calibrate the internal temperature sensor. NB! To set negative values; 65 535 – desired value + 1. Value: -100 to 100°C (Default 0, 0°C) Calibrate the internal hunidity sensor. NB! To set negative values; 65 535 – desired value + 1. Value: -100 to 100°C (Default 0, 0°C) value 2 to 270 seconds (Default 10, 10 seconds) Disable or enable sensor. Value 0 disable, 1 enable Adjust the backlight of LCD display. Adjust the time from proximity sensor / display touched until display goes to sleep.Value 3 to 300 seconds (Default 3, 3 seconds) Adjust the delta values for the thermostat to turn on off heating .Value 0.3 to 3°C (Default 5, 0,5°C) Set the mimum temperature limit.Value 5 to 40°C (Default 50, 5°C) Set the maximum temperature limit.5 to 40°C (Default 400, 40°C) Set time on how often the devices sends Binary Switch Set and thermostat mode to gateway. Value 0 : Sends only when changed (Default). 1 to 240 minutes + When changed Decides if the thermostat sends temperature when presence is detected.Value 0 : Do not report to gateway when presence is detected, only at interval.(Default) 1 : Send temperature report to gateway when presence is detected.