http://www.openzwave.com/device-database/019B:0201:0003 images/thermofloor/heatit021.png https://products.z-wavealliance.org/products/1234/ Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others. The display will show the actual room temperature. By pressing the buttons, the display will show the set value. Heatit Z-Wave is equipped with a single-pole switch. The thermostat can handle loads up to 16A/3600Wat 230V. If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors. FUNCTIONS • Room sensor • Floor sensor • Temperature limiter • Power regulator • Z-Wave chip 500 series • Week program/setback temperature via gateway • Setback mode • 7-segment LCD-screen • Can be used in connection with diff erent NTC-sensors • Lock mode/child lock • Backlight • Calibration • 8 scenarios CONNECTION CLAMPS Use 1,5 mm² or 2,5 mm² cables according to power need. TECHNICAL DATA Display LED-display 3x 7-Seg 13.2mm CA white Rated voltage: 230V 50/60Hz Max. load: 3600W Max. current: 16A Power consumption: 1,5W Protection class: IP21 Min/Max installation temp: -20°C to 40°C Min/Max operating temp: 5°C to 40°C Temperature range +5°C/+40°C Displayed temperature -30°C …. 60°C Floor min. limit 5°C (5°C…35°C) Floor max. limit 35°C (5°C…35°C) Air min. limit 5°C (5°C…40°C) Air max. limit 35°C (5°C…40°C) Regulator min. limit 0 (0…9) Power regulator P02 (P00…P10) cycle of 30 minutes Temperature setback Adjustable within temperature range. Temperature setback activation Pilot wire/Z-Wave user interface Hysteresis: 0,5°C Sensor values: 0°C 29,1 kOhm 10°C 18,6 kOhm 15°C 15,1 kOhm 20°C 12,2 kOhm 25°C 10,0 kOhm Switch: Single-pole Standard Color White RAL 9003 – Black RAL 9011 Approvals CE – FIMKO - Z-Wave Plus INCLUSION/EXCLUSION To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear. Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings. https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1182/Manual_Multireg%20Z-Wave_Ver2015-A.pdf CEPT (Europe) Heatit Z-Wave TF021 FACTORY RESET - RES By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset. NB! Please use this procedure only when the primary controller is missing or otherwise inoperable. INCLUSION/EXCLUSION To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear. Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings. If Er2 appears in the display, touch any button to restart the display. Initial release 37 0 true 0 true Set operation mode Set sensor mode Floor sensor type (10K NTC Default) 0-30 (0,3C - 3.0C) 50-400 (5.0C - 40.0C) 50-400 (5.0C - 40.0C) 50-400 (5.0C - 40.0C) 50-400 (5.0C - 40.0C) Min power 0-9 in FP-mode (Floor sensor and power regulator mode) 50-400 (5.0C - 40.0C) 50-400 (5.0C - 40.0C) Power 0-10 in P-mode (Power regulator mode) Only if cooling is enabled. 50-400 (5.0C - 40.0C) Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat) Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat) Temperature correction 0 - 4.0C (Default: 0). For positive value 40 = 4.0C. Negative value is not working (Adjust negativ calibration on thermostat) 0 (Report disabled) 1-8640 Multiply with 10 seconds, 10 seconds - 24 hours. Default is 6 (60 seconds) 1-100 (0.1C - 10C). Default is 10 (1.0C) true true