images/thermofloor/heatit20a.png https://products.z-wavealliance.org/products/3102/ Adding the device: When the primary controller is set to add/remove modus press the ”INCLUSION” button once on the device Z-Water Heatit Z-Water is equipped with 10 relay outputs and 4 analog inputs, and a Z-Wave radio for interfacing to the wireless Z-Wave network. The regulator can be power supplied from a 230V AC mains connection, and is able to deliver an output supply of 24V DC. Heatit Z-Water relay outputs are able to be freely controlled from the Z-Wave network, and can be used for several purposes, e.g. on/off control of light, control of valve actuators for an underfloor heating system, or control of other home automation systems. Heatit Z-Water inputs are analog inputs for interfacing simple temperature sensors; NTC, PT1000, etc. It is possible to configure the level and the indication of the status indicator LED in the front of the Heatit Z-Water regulator. https://Products.Z-WaveAlliance.org/ProductManual/File?folder=&filename=Manuals/3102/Manual_Heatit_Z-Water_analog%20inputs_FW%202.1_Ver2019-A_ENG.pdf Removing the device: When the primary controller is set to add/remove modus press the ”INCLUSION” button once on the device CEPT (Europe) By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset. NB! Please use this procedure only when the primary controller/ gateway is missing or otherwise inoperable. Heatit Z-Water Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/3102/xml Added ProductPic Fixed errors Set LED mode Set Brightnes This parameter decides which kind of thermistor that is connected to the input. This parameter decides which kind of thermistor that is connected to the input. This parameter decides which kind of thermistor that is connected to the input. This parameter decides which kind of thermistor that is connected to the input. -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. -40 - 40 (-4.0C - 4.0C) Default is 0 (0.0C) To set a negative value, use 255 and subtract the desired value. 0 (Report disabled) Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). 0 (Report disabled) Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). 0 (Report disabled) Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). 0 (Report disabled) Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). true true