| 1 |
What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory |
| 2 |
Date: August 2021 |
| 3 |
KernelVersion: 5.16 |
| 4 |
Contact: Jacopo Mondi <[email protected]> |
| 5 |
Description: |
| 6 |
Writing '1' triggers a 'Factory' calibration cycle. |
| 7 |
|
| 8 |
What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background |
| 9 |
Date: August 2021 |
| 10 |
KernelVersion: 5.16 |
| 11 |
Contact: Jacopo Mondi <[email protected]> |
| 12 |
Description: |
| 13 |
Writing '1' triggers a 'Background' calibration cycle. |
| 14 |
|
| 15 |
What: /sys/bus/iio/devices/iio:deviceX/error_status_available |
| 16 |
Date: August 2021 |
| 17 |
KernelVersion: 5.16 |
| 18 |
Contact: Jacopo Mondi <[email protected]> |
| 19 |
Description: |
| 20 |
Reading returns the list of possible chip error status. |
| 21 |
Available options are: |
| 22 |
- 'error_fatal': Analog front-end initialization error |
| 23 |
- 'error_i2c': Read/write to non-existing register |
| 24 |
- 'error_algorithm': Corrupted parameters |
| 25 |
- 'error_calibration': Calibration has failed |
| 26 |
- 'error_self_diagnostic': Internal interface failure |
| 27 |
- 'error_out_of_range': Measured concentration out of scale |
| 28 |
- 'error_memory': Error during memory operations |
| 29 |
- 'error_no_measurement': Cleared at first measurement |
| 30 |
- 'error_low_voltage': Sensor regulated voltage too low |
| 31 |
- 'error_measurement_timeout': Unable to complete measurement |
| 32 |
|
| 33 |
What: /sys/bus/iio/devices/iio:deviceX/error_status |
| 34 |
Date: August 2021 |
| 35 |
KernelVersion: 5.16 |
| 36 |
Contact: Jacopo Mondi <[email protected]> |
| 37 |
Description: |
| 38 |
Reading returns the current chip error status. |