| 1 |
# $Id$ |
| 2 |
# |
| 3 |
# prototype config file for the Eicon Diva ISDN Modem |
| 4 |
# |
| 5 |
|
| 6 |
# |
| 7 |
# CONFIG: CLASS2:Eicon*-*-* |
| 8 |
# |
| 9 |
# BEGIN-SERVER |
| 10 |
# END-SERVER |
| 11 |
# |
| 12 |
|
| 13 |
ModemType: Class2 |
| 14 |
ModemRate: 19200 # on boards supporting V.34-fax, |
| 15 |
# this may need to be 57600 |
| 16 |
ModemFlowControl: rtscts |
| 17 |
ModemNoFlowCmd: AT&K0 |
| 18 |
ModemSoftFlowCmd: AT&K4 |
| 19 |
ModemHardFlowCmd: AT&K3 |
| 20 |
|
| 21 |
# |
| 22 |
# Make sure the modem gives us Caller*ID in a legible way. |
| 23 |
# |
| 24 |
ModemResetCmds: AT#CID=14 |
| 25 |
|
| 26 |
# |
| 27 |
# Eicon recommends initializing with AT+iQ=a1 where "1" is |
| 28 |
# the controller number. This command binds the tty to that |
| 29 |
# controller and bypasses the "channel pool" approach. |
| 30 |
# |
| 31 |
#ModemResetCmds: AT#CID=14+iQ=a1 |
| 32 |
|
| 33 |
# |
| 34 |
# These should match the modem responses for DID and Caller*ID. |
| 35 |
# |
| 36 |
CallIDPattern: "DAD: " |
| 37 |
CallIDPattern: "CID: " |
| 38 |
|
| 39 |
Class2APQueryCmd: none |
| 40 |
Class2SPLCmd: none |
| 41 |
Class2TBCCmd: none |
| 42 |
Class2PHCTOCmd: none |
| 43 |
|
| 44 |
# |
| 45 |
# As Eicon's "Class 2" is a cross-breed and abomination between |
| 46 |
# Class 2.0, 2.1, and old-style 2 it may require some testing |
| 47 |
# to see if ECM type 2.0 or 2 is used and whether or not hexadecimal |
| 48 |
# is presented in the +FDCC response. |
| 49 |
# |
| 50 |
#Class2ECMType: 2.0 # follows Class 2.0 spec, not Class 2 |
| 51 |
Class2ECMType: 2 |
| 52 |
# |
| 53 |
Class2UseHex: true |
| 54 |
#Class2UseHex: false |