Debian Codegraph @

config/rc32acl

raw
1 # $Id$
2 #
3 # HylaFAX Facsimile Software
4 #
5 # Copyright (c) 1990-1996 Sam Leffler
6 # Copyright (c) 1991-1996 Silicon Graphics, Inc.
7 # HylaFAX is a trademark of Silicon Graphics, Inc.
8 #
9 # Permission to use, copy, modify, distribute, and sell this software and
10 # its documentation for any purpose is hereby granted without fee, provided
11 # that (i) the above copyright notices and this permission notice appear in
12 # all copies of the software and related documentation, and (ii) the names of
13 # Sam Leffler and Silicon Graphics may not be used in any advertising or
14 # publicity relating to the software without the specific, prior written
15 # permission of Sam Leffler and Silicon Graphics.
16 #
17 # THE SOFTWARE IS PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND,
18 # EXPRESS, IMPLIED OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY
19 # WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
20 #
21 # IN NO EVENT SHALL SAM LEFFLER OR SILICON GRAPHICS BE LIABLE FOR
22 # ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND,
23 # OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS,
24 # WHETHER OR NOT ADVISED OF THE POSSIBILITY OF DAMAGE, AND ON ANY THEORY OF
25 # LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE
26 # OF THIS SOFTWARE.
27 #
28
29 #
30 # Configuration for a Rockwell RC32ACL-based Class 2 modem.
31 # Boca M1440E firmware V1.000
32 # SupraFAX v.32bis firmware V1.000
33 # (and others)
34 #
35 # This configuration file sets up the modem to run at 38.4 for
36 # sending and for receiving. RTS/CTS is used for flow control
37 # which also works for data connections. Adaptive answer support
38 # is reliable, but to use it you must also enable ModemWaitForConnect
39 # to force the server to skip intermediate status messages and
40 # wait for the "CONNECT" message.
41 #
42 # CONFIG: CLASS2: ROCKWELL-RC32ACL*-*
43 #
44 # BEGIN-SERVER
45 # END-SERVER
46 #
47 # Modem-related stuff: should reflect modem command interface
48 # and hardware connection/cabling (e.g. flow control).
49 #
50 ModemType: Class2 # use class 2 interface
51 ModemRate: 19200
52 ModemFlowControl: rtscts # default
53 ModemWaitForConnect: yes # wait for CONNECT on answer
54 #
55 #ModemResetCmds: AT&F2 # what you want for a Supra
56 ModemNoFlowCmd: AT&K # disable flow control cmd
57 ModemHardFlowCmd: AT&K3 # hardware flow control cmd
58 ModemSoftFlowCmd: AT&K4 # software flow control cmd
59 ModemSetupDTRCmd: AT&D2 # DTR off causes modem to reset
60 ModemSetupDCDCmd: AT&C1 # DCD follows carrier
61 ModemSetupAACmd: AT+FCLASS=0;+FAA=1 # enable in class 0
62 #
63 ModemSendFillOrder: LSB2MSB # as expected
64 ModemRecvFillOrder: MSB2LSB # opposite of what makes sense
65 Class2RecvDataTrigger: "\022" # a la 2388-B
66 Class2APQueryCmd: none # prevent ERROR
67 Class2BUGCmd: none # prevent ERROR