Debian Codegraph @

config/lucent-mt-10

raw
1 # $Id$
2
3 #
4 # prototype config for MultiTech 5634-series modems using
5 # the Lucent/Agere chipset supporting V.34-Fax.
6 #
7
8 # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZPX-PCI*:.*:.*: Manufacturer=MultiTech Model=MT5634ZPX-PCI
9 # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZPX-PCI*:.*:.*: Manufacturer=MultiTech Model=MT5634ZPX-PCI-V92
10 # CONFIG:CLASS1.0:LT V.90 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
11 # CONFIG:CLASS1.0:LT V.92 1.0 MT5634ZBA*:.*:.*: Manufacturer=MultiTech Model=MT5634ZBA
12 # CONFIG:CLASS1.0:LT V.90 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
13 # CONFIG:CLASS1.0:LT V.92 1.0 ISI5634PCI*:.*:.*: Manufacturer=MultiTech Model=ISI5634PCI
14 # CONFIG:CLASS1.0:LT V.92 1.0 MT5634SMI*:.*:.*: Manufacturer=MultiTech Model=MT5634SMI
15 #
16 # BEGIN-SERVER
17 # END-SERVER
18
19 ModemType: Class1.0 # use this to supply a hint
20 ModemRate: 57600 # must be at least as fast as the DCE-DCE communication
21 ModemFlowControl: rtscts # many firmwares have broken software flow control
22 Class1EnableV34Cmd: AT+F34=14,1,2 # 33600-2400 primary, 2400-1200 control
23 Class1TMConnectDelay: 400 # counteract quick CONNECT response
24 Class1HasRHConnectBug: yes # cope with +FRH=3 CONNECT errors
25
26 # If your line supports Caller-ID, you may want to uncomment this...
27 # ModemResetCmds: AT+VCID=1
28 # CallIDPattern: "NMBR="
29 # CallIDPattern: "NAME="
30
31 # Or with the MT5634ZBA-DID you'll probably need something like...
32 # ModemReadyCmds: AT*DS1*DD0*DF1*DN4 # enable DTMF-DID, wink-start, 4 digits
33 # CallIDPattern: "DTMF" # format of AT*DF1
34 # CallIDAnswerLength: 4 # four DTMF-DID digits then ATA