# $Id$ # # prototype config file for the Eicon Diva ISDN Modem # # # CONFIG: CLASS2:Eicon*-*-* # # BEGIN-SERVER # END-SERVER # ModemType: Class2 ModemRate: 19200 # on boards supporting V.34-fax, # this may need to be 57600 ModemFlowControl: rtscts ModemNoFlowCmd: AT&K0 ModemSoftFlowCmd: AT&K4 ModemHardFlowCmd: AT&K3 # # Make sure the modem gives us Caller*ID in a legible way. # ModemResetCmds: AT#CID=14 # # Eicon recommends initializing with AT+iQ=a1 where "1" is # the controller number. This command binds the tty to that # controller and bypasses the "channel pool" approach. # #ModemResetCmds: AT#CID=14+iQ=a1 # # These should match the modem responses for DID and Caller*ID. # CallIDPattern: "DAD: " CallIDPattern: "CID: " Class2APQueryCmd: none Class2SPLCmd: none Class2TBCCmd: none Class2PHCTOCmd: none # # As Eicon's "Class 2" is a cross-breed and abomination between # Class 2.0, 2.1, and old-style 2 it may require some testing # to see if ECM type 2.0 or 2 is used and whether or not hexadecimal # is presented in the +FDCC response. # #Class2ECMType: 2.0 # follows Class 2.0 spec, not Class 2 Class2ECMType: 2 # Class2UseHex: true #Class2UseHex: false